BibTex RIS Cite

Reliability of the Turkish Version of a New Coma Scale: FOUR Score

Year 2010, Volume: 2010 Issue: 2, - , 01.02.2010

Abstract

Objectives: Although the most commonly used scale is the Glasgow Coma Scale (GCS) in neurological intensive care units (NICU), it has some shortcomings. Many attempts have been made to design new scales that could provide further neurological detail in coma. The FOUR score (Full Outline of UnResponsiveness) is a new coma scale. The aim of this study is the validation of the Turkish version of the FOUR score and comparison of it with the GCS. Patients and Methods: A total of consecutive 124 patients (65 males, 59 females; mean age 68.4±14.7 years; range 26 to 96 years) who were admitted to the seven NICUs between 2006-2007 were enrolled in the study. Each patient was rated on both scales by two different neurologists within one hour after each other without knowledge of the other's scores. Morbidity was assessed at hospital discharge using the modified Rankin Scale. Results: The inter-rater reliability was excellent for both FOUR score (K=0.68; %95 CI, 0.59-077) and GCS (K=0.69; %95 CI, 0.60-0.77). Outcome prediction of the FOUR score was as effective as GCS. Conclusion: The FOUR score has major advantages and provide important details of the neurologic examination such as brainstem reflexes and eye movements. We believe our results suggest that the FOUR score could be used instead of GCS in the NICUs in Turkey. Amaç: Nörolojik yoğun bakım ünitelerinde (NYBÜ) en sık kullanılan ölçek Glasgow Koma Skalası (GKS) olmakla birlikte bazı eksiklikleri nedeni ile eleştirilmekte ve nörolojik hastaların izlenmesinde daha iyi bir ölçek geliştirme çalışmaları devam etmektedir. FOUR skor (Full Outline of UnResponsiveness) yeni bir koma değerlendirme ölçeğidir. Bu çalışmanın amacı FOUR skorun Türkçe çevirisinin GKS ile karşılaştırılması ve gözlemciler arası güvenirliğinin saptanmasıdır. Hastalar ve Yöntemler: Çalışmaya, 2006-2007 yılları arasında yedi merkezin NYBÜ'lerinde yatan toplam 124 hasta (65 erkek, 59 kadın; ort. yaş 68.4±14.7; dağılım 26-96) dahil edildi. Her hasta, iki nöroloji doktoru tarafından, birbirinin değerlendirmelerinden habersiz ve en fazla bir saat aralıklı olacak şekilde muayene edildi ve FOUR skor ve GKS eş zamanlı olarak uygulandı. Hastaların prognozu modifiye Rankin Skalası (mRS) ile değerlendirildi. Bulgular: Uygulayıcılar arası uyumluluk hem FOUR skor için (K=0.68; %95 CI, 0.59-0.77) hem de GKS için (K=0.69; %95 CI, 0.60-0.77) iyi bulundu. FOUR skorun prognozu belirlemede GKS kadar etkili olduğu saptandı. Sonuç: FOUR skorun önemli üstünlükleri olup, beyin sapı refleksleri ve göz hareketleri gibi nörolojik muayenenin önemli ayrıntıları hakkında bilgi sağlar. Çalışmamızın sonuçlarının Türkiye'deki NYBÜ'lerde FOUR skorun GKS yerine kullanılabileceği görüşünü desteklediğine inanıyoruz.

Reliability of the Turkish Version of a New Coma Scale: FOUR Score

Year 2010, Volume: 2010 Issue: 2, - , 01.02.2010

Abstract

Objectives: Although the most commonly used scale is the Glasgow Coma Scale (GCS) in neurological intensive care units (NICU), it has some shortcomings. Many attempts have been made to design new scales that could provide further neurological detail in coma. The FOUR score (Full Outline of UnResponsiveness) is a new coma scale. The aim of this study is the validation of the Turkish version of the FOUR score and comparison of it with the GCS. Patients and Methods: A total of consecutive 124 patients (65 males, 59 females; mean age 68.4±14.7 years; range 26 to 96 years) who were admitted to the seven NICUs between 2006-2007 were enrolled in the study. Each patient was rated on both scales by two different neurologists within one hour after each other without knowledge of the other's scores. Morbidity was assessed at hospital discharge using the modified Rankin Scale. Results: The inter-rater reliability was excellent for both FOUR score (K=0.68; %95 CI, 0.59-077) and GCS (K=0.69; %95 CI, 0.60-0.77). Outcome prediction of the FOUR score was as effective as GCS. Conclusion: The FOUR score has major advantages and provide important details of the neurologic examination such as brainstem reflexes and eye movements. We believe our results suggest that the FOUR score could be used instead of GCS in the NICUs in Turkey. Amaç: Nörolojik yoğun bakım ünitelerinde (NYBÜ) en sık kullanılan ölçek Glasgow Koma Skalası (GKS) olmakla birlikte bazı eksiklikleri nedeni ile eleştirilmekte ve nörolojik hastaların izlenmesinde daha iyi bir ölçek geliştirme çalışmaları devam etmektedir. FOUR skor (Full Outline of UnResponsiveness) yeni bir koma değerlendirme ölçeğidir. Bu çalışmanın amacı FOUR skorun Türkçe çevirisinin GKS ile karşılaştırılması ve gözlemciler arası güvenirliğinin saptanmasıdır. Hastalar ve Yöntemler: Çalışmaya, 2006-2007 yılları arasında yedi merkezin NYBÜ'lerinde yatan toplam 124 hasta (65 erkek, 59 kadın; ort. yaş 68.4±14.7; dağılım 26-96) dahil edildi. Her hasta, iki nöroloji doktoru tarafından, birbirinin değerlendirmelerinden habersiz ve en fazla bir saat aralıklı olacak şekilde muayene edildi ve FOUR skor ve GKS eş zamanlı olarak uygulandı. Hastaların prognozu modifiye Rankin Skalası (mRS) ile değerlendirildi. Bulgular: Uygulayıcılar arası uyumluluk hem FOUR skor için (K=0.68; %95 CI, 0.59-0.77) hem de GKS için (K=0.69; %95 CI, 0.60-0.77) iyi bulundu. FOUR skorun prognozu belirlemede GKS kadar etkili olduğu saptandı. Sonuç: FOUR skorun önemli üstünlükleri olup, beyin sapı refleksleri ve göz hareketleri gibi nörolojik muayenenin önemli ayrıntıları hakkında bilgi sağlar. Çalışmamızın sonuçlarının Türkiye'deki NYBÜ'lerde FOUR skorun GKS yerine kullanılabileceği görüşünü desteklediğine inanıyoruz.

There are 0 citations in total.

Details

Primary Language Turkish
Journal Section Articles
Authors

Dilek Necioğlu Örken This is me

Ayşe Kocaman Sağduyu This is me

Hadiye Şirin This is me

Canan Togay Işıkara This is me

Mustafa Gökçe This is me

Nevin Sütlaş This is me

Şerefnur Öztürk This is me

Sultan Tarlacı

Publication Date February 1, 2010
Published in Issue Year 2010 Volume: 2010 Issue: 2

Cite

APA Örken, D. N., Sağduyu, A. K., Şirin, H., Işıkara, C. T., et al. (2010). Reliability of the Turkish Version of a New Coma Scale: FOUR Score. Balkan Medical Journal, 2010(2).
AMA Örken DN, Sağduyu AK, Şirin H, Işıkara CT, Gökçe M, Sütlaş N, Öztürk Ş, Tarlacı S. Reliability of the Turkish Version of a New Coma Scale: FOUR Score. Balkan Medical Journal. February 2010;2010(2).
Chicago Örken, Dilek Necioğlu, Ayşe Kocaman Sağduyu, Hadiye Şirin, Canan Togay Işıkara, Mustafa Gökçe, Nevin Sütlaş, Şerefnur Öztürk, and Sultan Tarlacı. “Reliability of the Turkish Version of a New Coma Scale: FOUR Score”. Balkan Medical Journal 2010, no. 2 (February 2010).
EndNote Örken DN, Sağduyu AK, Şirin H, Işıkara CT, Gökçe M, Sütlaş N, Öztürk Ş, Tarlacı S (February 1, 2010) Reliability of the Turkish Version of a New Coma Scale: FOUR Score. Balkan Medical Journal 2010 2
IEEE D. N. Örken, A. K. Sağduyu, H. Şirin, C. T. Işıkara, M. Gökçe, N. Sütlaş, Ş. Öztürk, and S. Tarlacı, “Reliability of the Turkish Version of a New Coma Scale: FOUR Score”, Balkan Medical Journal, vol. 2010, no. 2, 2010.
ISNAD Örken, Dilek Necioğlu et al. “Reliability of the Turkish Version of a New Coma Scale: FOUR Score”. Balkan Medical Journal 2010/2 (February 2010).
JAMA Örken DN, Sağduyu AK, Şirin H, Işıkara CT, Gökçe M, Sütlaş N, Öztürk Ş, Tarlacı S. Reliability of the Turkish Version of a New Coma Scale: FOUR Score. Balkan Medical Journal. 2010;2010.
MLA Örken, Dilek Necioğlu et al. “Reliability of the Turkish Version of a New Coma Scale: FOUR Score”. Balkan Medical Journal, vol. 2010, no. 2, 2010.
Vancouver Örken DN, Sağduyu AK, Şirin H, Işıkara CT, Gökçe M, Sütlaş N, Öztürk Ş, Tarlacı S. Reliability of the Turkish Version of a New Coma Scale: FOUR Score. Balkan Medical Journal. 2010;2010(2).