Abstract

Purpose: To demonstrate the results obtained as an outcome of using electronic cross-match (ECM) procedure which shortens the last phase of the preparation of one or more blood product output only by checking the ABO compliance that the patient does not have an alloantibody in life and confirmed by antibody screening with in the last 72 hours through inquiring the database and might reduce the costs. Methods: The patients transfused in whom ABO compatibility of the blood and blood product was investigated using ECM procedure in the hospital between the years 2014 and 2015 were included in the study. The prerequisites stipulated by American Association of Blood Banks, and indicated in its 2003 guideline were provided. The blood-typing and indirect Coombs (IC) tests have been analyzed by gel colon agglutination system. Results: During the study period, 25989 units packed red blood cells (RBCs) and 16 units whole blood were ordered from the clinics, and reserved for them. But 11254 units RBCs and 15 units whole blood were used. Crossmatch transfusion rate would be 2,3 if serologic crossmatch was performed to all of the blood products instead of ECM in transfusion laboratory. The costs of both procedures differed 2.07 times. During two years incompatible or mismatched blood transfusion and acute hemolytic transfusion reaction were not observed. Conclusion: The most important problem that can be experienced in the absence of blood products is the loss of human life which is beyond the limits of cost calculation. For this reason, it is thought that the advantages of the ECM model cannot be measured. It is thought that it will be beneficial to spread the usage of ECM in transfusion center laboratories without compromising quality standards and blood transfusion safety.

Keywords

References

  1. 1. TR0802.15-01/001 Türkiye’de Kan Tedarik Sisteminin Güçlendirilmesi Teknik Destek Projesi. Ulusal Kan ve Kan Bileşenleri Hazırlama, Kullanım ve Kalite Güvencesi Rehberi 2016; p-273
  2. 2. Lin DM, Goldfinger D, Lu Q, Wallace B, Kosaka-Nguyen D, Wood A, Porter B, Bumerts P, Jeffery R, Fang A, Stalcup I, Penaflorida T, Ziman A. Measuring trade-offs that matter: assessing the impact of a new electronic cross-match policy on the turnaround time and the cross-match workload efficiency. Transfusion. 2014;54:3075-9.
  3. 3. Arslan O. Electronic crossmatching. Transfus Med Rev. 2006; 20:75-9.
  4. 4. Reesink HW, Davis K, Wong J, Schwartz DW, Mayr WR, Devine DV, et al. The use of the electronic (computer) cross-match. Vox Sang. 2013;104: 350-64.
  5. 5. Judd WJ. Requirements for the electronic crossmatch. Vox Sang. 1998; 74 Suppl 2:409-17
  6. 6. Pereira A. Blood inventory management in the type and screen era. Vox Sang. 2005;89:245-50.
  7. 7. Chapman JF, Milkins C, Voak D. The computer crossmatch: a safe alternative to the serological crossmatch. Transfus Med. 2000;10:251-6.
  8. 8. Chan AH, Chan JC, Wong LY, Cheng G. From maximum surgical blood ordering schedule to unlimited computer crossmatching: evolution of blood transfusion for surgical patients at a tertiary hospital in Hong Kong. Transfus Med. 1996;6:121-4.

Details

Primary Language

English

Subjects

Clinical Sciences

Journal Section

Research Article

Publication Date

December 31, 2019

Submission Date

December 15, 2019

Acceptance Date

December 23, 2019

Published in Issue

Year 2019 Volume: 3 Number: 3

APA
Özdamar, M., Çetinkaya, F., Vardar, İ., Ergene, Ö., & Türkoğu, S. (2019). The Use of the Electronic Cross-Matching in Transfusion Center. Journal of Biotechnology and Strategic Health Research, 3(3), 250-254. https://doi.org/10.34084/bshr.659736
AMA
1.Özdamar M, Çetinkaya F, Vardar İ, Ergene Ö, Türkoğu S. The Use of the Electronic Cross-Matching in Transfusion Center. J Biotechnol and Strategic Health Res. 2019;3(3):250-254. doi:10.34084/bshr.659736
Chicago
Özdamar, Melda, Fuat Çetinkaya, İsmail Vardar, Ömer Ergene, and Salih Türkoğu. 2019. “The Use of the Electronic Cross-Matching in Transfusion Center”. Journal of Biotechnology and Strategic Health Research 3 (3): 250-54. https://doi.org/10.34084/bshr.659736.
EndNote
Özdamar M, Çetinkaya F, Vardar İ, Ergene Ö, Türkoğu S (December 1, 2019) The Use of the Electronic Cross-Matching in Transfusion Center. Journal of Biotechnology and Strategic Health Research 3 3 250–254.
IEEE
[1]M. Özdamar, F. Çetinkaya, İ. Vardar, Ö. Ergene, and S. Türkoğu, “The Use of the Electronic Cross-Matching in Transfusion Center”, J Biotechnol and Strategic Health Res, vol. 3, no. 3, pp. 250–254, Dec. 2019, doi: 10.34084/bshr.659736.
ISNAD
Özdamar, Melda - Çetinkaya, Fuat - Vardar, İsmail - Ergene, Ömer - Türkoğu, Salih. “The Use of the Electronic Cross-Matching in Transfusion Center”. Journal of Biotechnology and Strategic Health Research 3/3 (December 1, 2019): 250-254. https://doi.org/10.34084/bshr.659736.
JAMA
1.Özdamar M, Çetinkaya F, Vardar İ, Ergene Ö, Türkoğu S. The Use of the Electronic Cross-Matching in Transfusion Center. J Biotechnol and Strategic Health Res. 2019;3:250–254.
MLA
Özdamar, Melda, et al. “The Use of the Electronic Cross-Matching in Transfusion Center”. Journal of Biotechnology and Strategic Health Research, vol. 3, no. 3, Dec. 2019, pp. 250-4, doi:10.34084/bshr.659736.
Vancouver
1.Melda Özdamar, Fuat Çetinkaya, İsmail Vardar, Ömer Ergene, Salih Türkoğu. The Use of the Electronic Cross-Matching in Transfusion Center. J Biotechnol and Strategic Health Res. 2019 Dec. 1;3(3):250-4. doi:10.34084/bshr.659736

Journal of Biotechnology and Strategic Health Research