Abstract

In this study, the semi-direct and mixed types of lighting for the interior illumination have been compared in terms of technical aspects. The contribution of these lighting's type choices to the interior illumination has been address. Two different environments were selected and only the type of illumination was changed while all other physical condition of environments remains same. The semi-direct and mixed types of lighting were used for illumination and luminance level for each environment were measured 90cm above from the ground at many different points. These values were noted on a piece of paper as a matrix. Then, these values were drawn into a 3D graphic in MATLAB workspace to compare with each other. Thus, it has been observed that the chosen type of lighting system in design stage reduces the energy demand needed by the illumination elements. Consequently in this study, relationship of interior lighting type and its illumination level distribution were compared with numerical measurements. And it was concluded that the choice of lighting type contributes to illumination system positively in terms of both ergonomically and economical aspect

Keywords

References

  1. Akella, A.K. Saini, R.P. ve Sharma, M.P., ‘Social, economical and environmental impacts of renewable energy systems’, Proceedings of Renewable Energy, Elsevier, vol. 34, pp. 390-396, (2009).
  2. Sümengen, Ö. ve Yener, A., ‘Akıllı Konutlarda Aydınlatma ve Örnekler’ 8.ci Ulusal Aydınlatma Kongresi ATMK, 14-15 Nisan (2011).
  3. Varınca B.K. ve Gönüllü, M.T., ‘Türkiye’de Güneş Enerjisi Potansiyeli ve Bu Potansiyelin Kullanım Derecesi, Yöntemi ve Yaygınlığı Üzerine Bir Araştırma , I. Ulusal Güneş ve Hidrojen Enerjisi Kongresi Eskişehir.
  4. Shafiullah, G.M., Amanullah M. T., Jarvis D., Shawkat A. ve Wolfs P., 2010, “Prospects of solar energy in Australia”, 6th International Conference on Electrical and Computer Engineering, pp. 350-353, (2010).
  5. Cullen, J. M., Allwood, J. M. ve Borgstein, E. H., “Reducing energy demand: What are the practical limits?”, Cambridge, Vol. 45, pp. 1711-1718, (2011).
  6. Matta, S. ve Mahmud, S.M., “An intelligent light control system for power saving”, 36th Annual Conference on IEEE Industrial Electronics Society, pp. 3316 – 332, (2010).
  7. Galasiu, A.D., Newsham, G.R., Suvagau, C. ve Sander, D.M., “Energy saving lighting control systems for open-plan offices: a field study”, Leukos, vol. 4, pp. 7-29, (2007).
  8. Dubin, F.S., “Energy-efficient building design. Innovative HVAC, lighting, energy-management control, and fenestration”, Elsevier, vol.36, pp. 11-20, (1990).

Details

Primary Language

English

Subjects

Engineering

Journal Section

Research Article

Authors

Mustafa Şahin This is me

Fuat Büyüktümtürk This is me

Publication Date

July 6, 2015

Submission Date

July 6, 2015

Acceptance Date

-

Published in Issue

Year 2015 Volume: 11 Number: 1

APA
Şahin, M., Oğuz, Y., & Büyüktümtürk, F. (2015). COMPARISON OF THE SEMI-DIRECT AND MIXED TYPE OF LIGHTING IN TERMS OF TECHNICAL ASPECTS. Celal Bayar University Journal of Science, 11(1), 25-35. https://doi.org/10.18466/cbufbe.43253
AMA
1.Şahin M, Oğuz Y, Büyüktümtürk F. COMPARISON OF THE SEMI-DIRECT AND MIXED TYPE OF LIGHTING IN TERMS OF TECHNICAL ASPECTS. CBUJOS. 2015;11(1):25-35. doi:10.18466/cbufbe.43253
Chicago
Şahin, Mustafa, Yüksel Oğuz, and Fuat Büyüktümtürk. 2015. “COMPARISON OF THE SEMI-DIRECT AND MIXED TYPE OF LIGHTING IN TERMS OF TECHNICAL ASPECTS”. Celal Bayar University Journal of Science 11 (1): 25-35. https://doi.org/10.18466/cbufbe.43253.
EndNote
Şahin M, Oğuz Y, Büyüktümtürk F (July 1, 2015) COMPARISON OF THE SEMI-DIRECT AND MIXED TYPE OF LIGHTING IN TERMS OF TECHNICAL ASPECTS. Celal Bayar University Journal of Science 11 1 25–35.
IEEE
[1]M. Şahin, Y. Oğuz, and F. Büyüktümtürk, “COMPARISON OF THE SEMI-DIRECT AND MIXED TYPE OF LIGHTING IN TERMS OF TECHNICAL ASPECTS”, CBUJOS, vol. 11, no. 1, pp. 25–35, July 2015, doi: 10.18466/cbufbe.43253.
ISNAD
Şahin, Mustafa - Oğuz, Yüksel - Büyüktümtürk, Fuat. “COMPARISON OF THE SEMI-DIRECT AND MIXED TYPE OF LIGHTING IN TERMS OF TECHNICAL ASPECTS”. Celal Bayar University Journal of Science 11/1 (July 1, 2015): 25-35. https://doi.org/10.18466/cbufbe.43253.
JAMA
1.Şahin M, Oğuz Y, Büyüktümtürk F. COMPARISON OF THE SEMI-DIRECT AND MIXED TYPE OF LIGHTING IN TERMS OF TECHNICAL ASPECTS. CBUJOS. 2015;11:25–35.
MLA
Şahin, Mustafa, et al. “COMPARISON OF THE SEMI-DIRECT AND MIXED TYPE OF LIGHTING IN TERMS OF TECHNICAL ASPECTS”. Celal Bayar University Journal of Science, vol. 11, no. 1, July 2015, pp. 25-35, doi:10.18466/cbufbe.43253.
Vancouver
1.Mustafa Şahin, Yüksel Oğuz, Fuat Büyüktümtürk. COMPARISON OF THE SEMI-DIRECT AND MIXED TYPE OF LIGHTING IN TERMS OF TECHNICAL ASPECTS. CBUJOS. 2015 Jul. 1;11(1):25-3. doi:10.18466/cbufbe.43253