PDF EndNote BibTex RIS Cite

Polarographic Determination of Lornoxicam in Pharmaceutical Formulations

Year 2009, Volume 5, Issue 1, 13 - 18, 01.03.2009

Abstract

-

References

  • 1] Radhofer-Welte S., Dittrich P., “Determination of the novel non-steroidal antiinflammatory drug lornoxicam and its main metabolite in plasma and synovial fluid”, J. Chrom. B, 707: 151–159, 1998.
  • [2] Atzpadien E., Mehdi N., Clarke D., et al., “Subacute and chronic oral toxicity of lornoxicam in cynnomolgus monkeys”, Food Anal. Chem. Toxicol., 35: 465–474, 1997.
  • [3] Velpandian T., Jaiswal J., Bhardwaj R. K., “Gupta S. K., Development and validation of a new high-performance liquid chromatographic estimation method of meloxicam in biological samples”, J. Chrom. B, 738: 431–436, 2000.
  • [4] Ozaltin N., “Differential pulse polarographic determination of tenoxicam in pharmaceuticals and added to blood”, Anal. Chim. Acta, 406: 183–189, 2000. [5] Altinoz S., Nemutlu E., Kir S., “Polarographic behaviour of meloxicam and its determination in tablet preparations and spiked plasma”, Il Farmaco, 57: 463–468, 2002.
  • [6] Ghoneim M. M., Beltagi A. M., Radi, A., “Square-wave adsorptive stripping voltammetric determination of the anti-inflammatory drug lornoxicam”, Anal. Sci., 18[2]: 183–186, 2002.
  • [7] Hein A., Norlander C., Blom L., et al., “Is pain pophylaxis in minor gynaecological surgery of clinical value? A double-blind placebo controlled study of paracetamol 1 g versus lornoxicam 8 mg given orally”, Ambulatory Surgery, 9[2]: 91–94, 2001.
  • [8] Ozgur M. U., Aycan S., Islimyeli S., “Differential pulse polarographic determination of prazosin hydrochloride in tablets”, Die Pharmazie, 50: 435–436, 1995.
  • [9] Ozgur M. U., Islimyeli S., Aycan S., “Differential pulse polarographic determination of doxasocin mesylate in tablets”, Die Pharmazie, 52[7]: 561–562, 1997.
  • [10] Coskun N. Y., Aycan S., Sungur S., “Differential pulse polarographic determination of pravastatin sodium in tablets”, Die Pharmazie, 52[6]: 485–486, 1997.
  • [11] Elmali F., Alpdogan G., Sungur S., Aycan S., “Polarographic determination of fluvoxamine maleate in tablets”, Turkish J. Chem., 24: 299– 302, 2000.
  • [12] Elmali F., Alpdogan G., Aycan S., Sungur S., “Differential pulse polarographic determination of enalapril maleate”, Turkish J. Chem., 27: 65–69, 2003.

POLAROGRAPHIC DETERMINATION OF LORNOXICAM IN PHARMACEUTICAL FORMULATIONS - FARMASÖTİK FORMÜLLERDEKİ LORNOKSİKAMIN POLAROGRAFİK TAYİNİ

Year 2009, Volume 5, Issue 1, 13 - 18, 01.03.2009

Abstract

POLAROGRAPHIC DETERMINATION OF LORNOXICAM IN PHARMACEUTICAL FORMULATIONS

A simple, precise, fast and low-cost differential pulse polarographic (DPP) method for
determination of lornoxicam in pharmaceutical formulations has been proposed. The results have been
compared with those of high performance liquid chromatography (HPLC) method. Mean values and
standard deviations calculated by ten determinations were 8.10 ± 0.12 mg for DPP and six determinations
were 8.02 ± 0.08 mg for the HPLC method. The statistical evaluations indicated that there was no significant
difference between the mean values and precessions of the two methods at 95% confidence level (t=2.64,
F=2.25)

FARMASÖTİK FORMÜLLERDEKİ LORNOKSİKAMIN POLAROGRAFİK TAYİNİ

Bu çalısmada farmasötik formüllerde bulunan lornoksikamı tayin etmek için basit, duyarlı, hızlı ve
ucuz bir yöntem önerilmistir. Bu yöntemle elde edilen sonuçlar yüksek performanslı sıvı kromatografisi
(HPLC) yöntemi ile elde edilenlerle karsılastırılmıstır. Tabletlerdeki lornoksikam miktarı için ortalama
degerler ve standart sapmalar diferansiyel puls polarografik (DPP) yöntem için on tayinle 8.10 ± 0.12 mg,
HPLC için altı tayinle 8.02 ± 0.08 mg olarak hesaplanmıstır. statistiksel degerlendirme, % 95 güvenirlik
düzeyinde bu iki yöntem arasında ortalama degerler ve duyarlık bakımından önemli bir fark olmadıgını
göstermistir (t=2.64, F=2.25).

References

  • 1] Radhofer-Welte S., Dittrich P., “Determination of the novel non-steroidal antiinflammatory drug lornoxicam and its main metabolite in plasma and synovial fluid”, J. Chrom. B, 707: 151–159, 1998.
  • [2] Atzpadien E., Mehdi N., Clarke D., et al., “Subacute and chronic oral toxicity of lornoxicam in cynnomolgus monkeys”, Food Anal. Chem. Toxicol., 35: 465–474, 1997.
  • [3] Velpandian T., Jaiswal J., Bhardwaj R. K., “Gupta S. K., Development and validation of a new high-performance liquid chromatographic estimation method of meloxicam in biological samples”, J. Chrom. B, 738: 431–436, 2000.
  • [4] Ozaltin N., “Differential pulse polarographic determination of tenoxicam in pharmaceuticals and added to blood”, Anal. Chim. Acta, 406: 183–189, 2000. [5] Altinoz S., Nemutlu E., Kir S., “Polarographic behaviour of meloxicam and its determination in tablet preparations and spiked plasma”, Il Farmaco, 57: 463–468, 2002.
  • [6] Ghoneim M. M., Beltagi A. M., Radi, A., “Square-wave adsorptive stripping voltammetric determination of the anti-inflammatory drug lornoxicam”, Anal. Sci., 18[2]: 183–186, 2002.
  • [7] Hein A., Norlander C., Blom L., et al., “Is pain pophylaxis in minor gynaecological surgery of clinical value? A double-blind placebo controlled study of paracetamol 1 g versus lornoxicam 8 mg given orally”, Ambulatory Surgery, 9[2]: 91–94, 2001.
  • [8] Ozgur M. U., Aycan S., Islimyeli S., “Differential pulse polarographic determination of prazosin hydrochloride in tablets”, Die Pharmazie, 50: 435–436, 1995.
  • [9] Ozgur M. U., Islimyeli S., Aycan S., “Differential pulse polarographic determination of doxasocin mesylate in tablets”, Die Pharmazie, 52[7]: 561–562, 1997.
  • [10] Coskun N. Y., Aycan S., Sungur S., “Differential pulse polarographic determination of pravastatin sodium in tablets”, Die Pharmazie, 52[6]: 485–486, 1997.
  • [11] Elmali F., Alpdogan G., Sungur S., Aycan S., “Polarographic determination of fluvoxamine maleate in tablets”, Turkish J. Chem., 24: 299– 302, 2000.
  • [12] Elmali F., Alpdogan G., Aycan S., Sungur S., “Differential pulse polarographic determination of enalapril maleate”, Turkish J. Chem., 27: 65–69, 2003.

Details

Primary Language Turkish
Journal Section Articles
Authors

İbrahim ÇETİN This is me


Nisa KOÇAK This is me


Şule AYCAN>

Publication Date March 1, 2009
Acceptance Date
Published in Issue Year 2009, Volume 5, Issue 1

Cite

Bibtex @ { cbayarfbe53361, journal = {Celal Bayar University Journal of Science}, issn = {1305-130X}, eissn = {1305-1385}, address = {}, publisher = {Celal Bayar University}, year = {2009}, volume = {5}, number = {1}, pages = {13 - 18}, title = {POLAROGRAPHIC DETERMINATION OF LORNOXICAM IN PHARMACEUTICAL FORMULATIONS - FARMASÖTİK FORMÜLLERDEKİ LORNOKSİKAMIN POLAROGRAFİK TAYİNİ}, key = {cite}, author = {Çetin, İbrahim and Koçak, Nisa and Aycan, Şule} }
APA Çetin, İ. , Koçak, N. & Aycan, Ş. (2009). POLAROGRAPHIC DETERMINATION OF LORNOXICAM IN PHARMACEUTICAL FORMULATIONS - FARMASÖTİK FORMÜLLERDEKİ LORNOKSİKAMIN POLAROGRAFİK TAYİNİ . Celal Bayar University Journal of Science , 5 (1) , 13-18 . Retrieved from https://dergipark.org.tr/en/pub/cbayarfbe/issue/4048/53361
MLA Çetin, İ. , Koçak, N. , Aycan, Ş. "POLAROGRAPHIC DETERMINATION OF LORNOXICAM IN PHARMACEUTICAL FORMULATIONS - FARMASÖTİK FORMÜLLERDEKİ LORNOKSİKAMIN POLAROGRAFİK TAYİNİ" . Celal Bayar University Journal of Science 5 (2009 ): 13-18 <https://dergipark.org.tr/en/pub/cbayarfbe/issue/4048/53361>
Chicago Çetin, İ. , Koçak, N. , Aycan, Ş. "POLAROGRAPHIC DETERMINATION OF LORNOXICAM IN PHARMACEUTICAL FORMULATIONS - FARMASÖTİK FORMÜLLERDEKİ LORNOKSİKAMIN POLAROGRAFİK TAYİNİ". Celal Bayar University Journal of Science 5 (2009 ): 13-18
RIS TY - JOUR T1 - Polarographic Determination of Lornoxicam in Pharmaceutical Formulations AU - İbrahimÇetin, NisaKoçak, ŞuleAycan Y1 - 2009 PY - 2009 N1 - DO - T2 - Celal Bayar University Journal of Science JF - Journal JO - JOR SP - 13 EP - 18 VL - 5 IS - 1 SN - 1305-130X-1305-1385 M3 - UR - Y2 - 2022 ER -
EndNote %0 Celal Bayar University Journal of Science POLAROGRAPHIC DETERMINATION OF LORNOXICAM IN PHARMACEUTICAL FORMULATIONS - FARMASÖTİK FORMÜLLERDEKİ LORNOKSİKAMIN POLAROGRAFİK TAYİNİ %A İbrahim Çetin , Nisa Koçak , Şule Aycan %T POLAROGRAPHIC DETERMINATION OF LORNOXICAM IN PHARMACEUTICAL FORMULATIONS - FARMASÖTİK FORMÜLLERDEKİ LORNOKSİKAMIN POLAROGRAFİK TAYİNİ %D 2009 %J Celal Bayar University Journal of Science %P 1305-130X-1305-1385 %V 5 %N 1 %R %U
ISNAD Çetin, İbrahim , Koçak, Nisa , Aycan, Şule . "POLAROGRAPHIC DETERMINATION OF LORNOXICAM IN PHARMACEUTICAL FORMULATIONS - FARMASÖTİK FORMÜLLERDEKİ LORNOKSİKAMIN POLAROGRAFİK TAYİNİ". Celal Bayar University Journal of Science 5 / 1 (March 2009): 13-18 .
AMA Çetin İ. , Koçak N. , Aycan Ş. POLAROGRAPHIC DETERMINATION OF LORNOXICAM IN PHARMACEUTICAL FORMULATIONS - FARMASÖTİK FORMÜLLERDEKİ LORNOKSİKAMIN POLAROGRAFİK TAYİNİ. CBUJOS. 2009; 5(1): 13-18.
Vancouver Çetin İ. , Koçak N. , Aycan Ş. POLAROGRAPHIC DETERMINATION OF LORNOXICAM IN PHARMACEUTICAL FORMULATIONS - FARMASÖTİK FORMÜLLERDEKİ LORNOKSİKAMIN POLAROGRAFİK TAYİNİ. Celal Bayar University Journal of Science. 2009; 5(1): 13-18.
IEEE İ. Çetin , N. Koçak and Ş. Aycan , "POLAROGRAPHIC DETERMINATION OF LORNOXICAM IN PHARMACEUTICAL FORMULATIONS - FARMASÖTİK FORMÜLLERDEKİ LORNOKSİKAMIN POLAROGRAFİK TAYİNİ", Celal Bayar University Journal of Science, vol. 5, no. 1, pp. 13-18, Mar. 2009