BibTex RIS Cite

Thermodynamic Analysis of a Desiccant Cooling System

Year 2011, Volume: 26 Issue: 2 - Volume: 26 Issue: 2, 119 - 126, 25.07.2016

Abstract

In this study thermodynamic analysis of a desiccant based evaporative cooling system is carried out. A cooling machine reaching theoretically the maximum coefficient of performance is known as Carnot COP. The Carnot COP and second law efficiency of the system is calculated in this analysis. Effect of outdoor temperature and relative humidity on actual COP, Carnot COP, cooling load and second law efficiency is investigated. The minimum Carnot COP value is calculated as 4.56 and it is observed that the Carnot COP value is decreasing while outdoor air temperature is increasing

Nem Almalı Bir Soğutma Sisteminin Termodinamik Analizi

Year 2011, Volume: 26 Issue: 2 - Volume: 26 Issue: 2, 119 - 126, 25.07.2016

Abstract

Bu çalışmada nem almalı bir soğutma sisteminin termodinamik analizi yapılmıştır. Bir soğutma makinesinin teorik olarak ulaşabileceği en yüksek etkinlik değeri Carnot COP değeri olarak bilinir. Bu analizde Carnot COP değeri ve sistemin ikinci yasa verimi hesaplanmıştır. Dış hava sıcaklığı ve bağıl nem değerlerinin sistemin gerçek COP değeri, Carnot COP değeri, soğutma kapasitesi ve ikinci yasa verimlerine etkisi incelenmiştir. Carnot COP değerinin yapılan hesaplamalarda en düşük 4.56 olduğu ve dış hava sıcaklığının artmasına bağlı olarak azaldığı görülmüştür

There are 0 citations in total.

Details

Other ID JA33VY55KM
Journal Section Articles
Authors

İrfan Uçkan This is me

Tuncay Yılmaz This is me

Publication Date July 25, 2016
Published in Issue Year 2011 Volume: 26 Issue: 2 - Volume: 26 Issue: 2

Cite

APA Uçkan, İ., & Yılmaz, T. (2016). Nem Almalı Bir Soğutma Sisteminin Termodinamik Analizi. Çukurova Üniversitesi Mühendislik-Mimarlık Fakültesi Dergisi, 26(2), 119-126.
AMA Uçkan İ, Yılmaz T. Nem Almalı Bir Soğutma Sisteminin Termodinamik Analizi. cukurovaummfd. July 2016;26(2):119-126.
Chicago Uçkan, İrfan, and Tuncay Yılmaz. “Nem Almalı Bir Soğutma Sisteminin Termodinamik Analizi”. Çukurova Üniversitesi Mühendislik-Mimarlık Fakültesi Dergisi 26, no. 2 (July 2016): 119-26.
EndNote Uçkan İ, Yılmaz T (July 1, 2016) Nem Almalı Bir Soğutma Sisteminin Termodinamik Analizi. Çukurova Üniversitesi Mühendislik-Mimarlık Fakültesi Dergisi 26 2 119–126.
IEEE İ. Uçkan and T. Yılmaz, “Nem Almalı Bir Soğutma Sisteminin Termodinamik Analizi”, cukurovaummfd, vol. 26, no. 2, pp. 119–126, 2016.
ISNAD Uçkan, İrfan - Yılmaz, Tuncay. “Nem Almalı Bir Soğutma Sisteminin Termodinamik Analizi”. Çukurova Üniversitesi Mühendislik-Mimarlık Fakültesi Dergisi 26/2 (July 2016), 119-126.
JAMA Uçkan İ, Yılmaz T. Nem Almalı Bir Soğutma Sisteminin Termodinamik Analizi. cukurovaummfd. 2016;26:119–126.
MLA Uçkan, İrfan and Tuncay Yılmaz. “Nem Almalı Bir Soğutma Sisteminin Termodinamik Analizi”. Çukurova Üniversitesi Mühendislik-Mimarlık Fakültesi Dergisi, vol. 26, no. 2, 2016, pp. 119-26.
Vancouver Uçkan İ, Yılmaz T. Nem Almalı Bir Soğutma Sisteminin Termodinamik Analizi. cukurovaummfd. 2016;26(2):119-26.