BibTex RIS Cite
Year 2015, Volume: 36 Issue: 3, 1648 - 1656, 13.05.2015

Abstract

References

  • ZareMahzabeeyeh, 2012, "systems used in Oil, gas, and petrochemical industries”, comprehensive data pertonet, p1-9.
  • U.S. Environmental Protection Agency, 2000,"316(b) Phase II Technical Development Document”, Chapter 6, Environmental Protection Agency. PP 1-12.
  • Ibraheemi, Gh, 2001, "Engineering of cooling towers"(wet), Tehran, Tehran univ. Office of publication and print, first publication, pages 243-269.
  • Peters, H.T, Translated by: Shayeghan, J &Sanayee- zadi M. 2009, "Factory Designing and economical estimation for chemical engineers", Tehran: Nu- pardazan, first pubplication, pp. 294-496.
  • McCabe W.L., Smith J.C., Herriot P, (2001),”Unit operation of chemical engineering”, sixth edition, McGraw Hill, International Edition, pp.541-549 .

Energy efficiency and system optimization by replacing of water cooled condenser with air cooler in zagros petrochemical complex

Year 2015, Volume: 36 Issue: 3, 1648 - 1656, 13.05.2015

Abstract

Abstract. In this paper, the feasibility of replacing the water cooled condenser instead air cooler of using disposable technologies once through and cooling tower water is salty and sweet of economic operations is examined. In hot and humid areas of our country like assluyeh, wide temperature changes during the day especially in warm seasons of year affect the atmospheric distillation tower conditions for purification of products both in quantity and quality. This changeable temperature conditions cause the waste of produced methanol from the bottom of tower and cooling operation in air cooler wouldn’t be well done. Since air is as coolant in air cooler and due to low heat capacity of air (1.0035j/g k) to water (4.1813j/g k), this types of exchangers have lower heat efficiency. Because there’s access to water sources of Persian Gulf, the feasibility of substituting water exchanger by using once through technology, the salt water or desalt water cooling tower was studied based on practical and economic issues. Based on these studies, it is suggested to apply water exchanger which use cooling tower technology of sweet water accompanied by sweet water maker (MED) set instead of air cooler in Zagros petrochemical complex. Because this project not only has higher practical efficiency considering to air cooler but also can save a lot of electricity and the expenditure of maintenance of equipment will be decreased.

References

  • ZareMahzabeeyeh, 2012, "systems used in Oil, gas, and petrochemical industries”, comprehensive data pertonet, p1-9.
  • U.S. Environmental Protection Agency, 2000,"316(b) Phase II Technical Development Document”, Chapter 6, Environmental Protection Agency. PP 1-12.
  • Ibraheemi, Gh, 2001, "Engineering of cooling towers"(wet), Tehran, Tehran univ. Office of publication and print, first publication, pages 243-269.
  • Peters, H.T, Translated by: Shayeghan, J &Sanayee- zadi M. 2009, "Factory Designing and economical estimation for chemical engineers", Tehran: Nu- pardazan, first pubplication, pp. 294-496.
  • McCabe W.L., Smith J.C., Herriot P, (2001),”Unit operation of chemical engineering”, sixth edition, McGraw Hill, International Edition, pp.541-549 .
There are 5 citations in total.

Details

Journal Section Special
Authors

Mohammad Gholipour

Publication Date May 13, 2015
Published in Issue Year 2015 Volume: 36 Issue: 3

Cite

APA Gholipour, M. (2015). Energy efficiency and system optimization by replacing of water cooled condenser with air cooler in zagros petrochemical complex. Cumhuriyet Üniversitesi Fen Edebiyat Fakültesi Fen Bilimleri Dergisi, 36(3), 1648-1656.
AMA Gholipour M. Energy efficiency and system optimization by replacing of water cooled condenser with air cooler in zagros petrochemical complex. Cumhuriyet Üniversitesi Fen Edebiyat Fakültesi Fen Bilimleri Dergisi. May 2015;36(3):1648-1656.
Chicago Gholipour, Mohammad. “Energy Efficiency and System Optimization by Replacing of Water Cooled Condenser With Air Cooler in Zagros Petrochemical Complex”. Cumhuriyet Üniversitesi Fen Edebiyat Fakültesi Fen Bilimleri Dergisi 36, no. 3 (May 2015): 1648-56.
EndNote Gholipour M (May 1, 2015) Energy efficiency and system optimization by replacing of water cooled condenser with air cooler in zagros petrochemical complex. Cumhuriyet Üniversitesi Fen Edebiyat Fakültesi Fen Bilimleri Dergisi 36 3 1648–1656.
IEEE M. Gholipour, “Energy efficiency and system optimization by replacing of water cooled condenser with air cooler in zagros petrochemical complex”, Cumhuriyet Üniversitesi Fen Edebiyat Fakültesi Fen Bilimleri Dergisi, vol. 36, no. 3, pp. 1648–1656, 2015.
ISNAD Gholipour, Mohammad. “Energy Efficiency and System Optimization by Replacing of Water Cooled Condenser With Air Cooler in Zagros Petrochemical Complex”. Cumhuriyet Üniversitesi Fen Edebiyat Fakültesi Fen Bilimleri Dergisi 36/3 (May 2015), 1648-1656.
JAMA Gholipour M. Energy efficiency and system optimization by replacing of water cooled condenser with air cooler in zagros petrochemical complex. Cumhuriyet Üniversitesi Fen Edebiyat Fakültesi Fen Bilimleri Dergisi. 2015;36:1648–1656.
MLA Gholipour, Mohammad. “Energy Efficiency and System Optimization by Replacing of Water Cooled Condenser With Air Cooler in Zagros Petrochemical Complex”. Cumhuriyet Üniversitesi Fen Edebiyat Fakültesi Fen Bilimleri Dergisi, vol. 36, no. 3, 2015, pp. 1648-56.
Vancouver Gholipour M. Energy efficiency and system optimization by replacing of water cooled condenser with air cooler in zagros petrochemical complex. Cumhuriyet Üniversitesi Fen Edebiyat Fakültesi Fen Bilimleri Dergisi. 2015;36(3):1648-56.