EN
TR
ACTIVE NOISE CONTROLLER DESIGN AND IMPLEMENTATION FOR DENTAL DRILL NOISE
Abstract
Dental drills produce a high frequency sound that disturbs the patients and can be called as noise. The sound of dentist drill is not only disturbing but also has adverse effects on human health so it is needed to be suppressed with noise control methods. In this study, the dentist drill noise has tried to be suppressed in open field with an Active Noise Control (ANC) system that consists of microphones, speaker and a digital signal processing card. The study differs from the ANC studies in the literature in terms of the algorithm used and the attempt to suppress a high frequency noise with ANC method in an open field. According to the implementation results, the performance of the proposed ANC system is satisfactory
References
- Zubick H.H., Tolentino, A.T., Boffa, J. 1980. Hearing Loss and the High Speed Dental Handpiece, American Journal of Public Health, Cilt.70, no:6, s. 633-635.
- Theodoroff, S. M., Folmer, R. L. 2013. Hearing Loss Associated with Long-Term Exposure to High- Speed Dental Handpieces, General Dentistry.
- Rotter, K. R. G. R., Atherton, M. A., Kaymak, E., ve Millar, B. J. 2008. Noise reduction of dental drill noise. Mechatronics 2008, 23-25 Haziran, İrlanda, 1-5.
- Kaymak, E., Atherton M. 2006. Active Noise Control at Higher Frequencies.
- International Congress on Sound and Vibration, 2-6 Temmuz, Viyana, Avusturya, 275-281.
- DOI: 10.13140/RG.2.1.4621.2886
- Kuo, S. M., Morgan, D. 1995. Active Noise Control Systems: Algorithms and DSP Implementations. John Wiley & Sons, Inc. 389s.
- Thanigai, P., Kuo, S. M., Yenduri, R. 2007. Nonlinear Active Noise Control For Infant Incubators in Neo-Natal İntensive Care Units. IEEE International Conference on Acoustics, Speech and Signal Processing, ICASSP 2007, 16-20 Nisan, Honolulu Amerika 109-112. DOI: 10.1109/ICASSP.2007.36662 8.
Details
Primary Language
Turkish
Subjects
-
Journal Section
-
Publication Date
May 1, 2018
Submission Date
May 1, 2018
Acceptance Date
-
Published in Issue
Year 2018 Volume: 20 Number: 59
APA
Kahraman, H., & Doğan, H. (2018). DİŞÇİ DELGİSİ GÜRÜLTÜSÜ İÇİN AKTİF GÜRÜLTÜ DENETLEYİCİ TASARIMI VE UYGULAMASI. Dokuz Eylül Üniversitesi Mühendislik Fakültesi Fen Ve Mühendislik Dergisi, 20(59), 555-565. https://izlik.org/JA62JX32EL
AMA
1.Kahraman H, Doğan H. DİŞÇİ DELGİSİ GÜRÜLTÜSÜ İÇİN AKTİF GÜRÜLTÜ DENETLEYİCİ TASARIMI VE UYGULAMASI. DEUFMD. 2018;20(59):555-565. https://izlik.org/JA62JX32EL
Chicago
Kahraman, Hakan, and Hatice Doğan. 2018. “DİŞÇİ DELGİSİ GÜRÜLTÜSÜ İÇİN AKTİF GÜRÜLTÜ DENETLEYİCİ TASARIMI VE UYGULAMASI”. Dokuz Eylül Üniversitesi Mühendislik Fakültesi Fen Ve Mühendislik Dergisi 20 (59): 555-65. https://izlik.org/JA62JX32EL.
EndNote
Kahraman H, Doğan H (May 1, 2018) DİŞÇİ DELGİSİ GÜRÜLTÜSÜ İÇİN AKTİF GÜRÜLTÜ DENETLEYİCİ TASARIMI VE UYGULAMASI. Dokuz Eylül Üniversitesi Mühendislik Fakültesi Fen ve Mühendislik Dergisi 20 59 555–565.
IEEE
[1]H. Kahraman and H. Doğan, “DİŞÇİ DELGİSİ GÜRÜLTÜSÜ İÇİN AKTİF GÜRÜLTÜ DENETLEYİCİ TASARIMI VE UYGULAMASI”, DEUFMD, vol. 20, no. 59, pp. 555–565, May 2018, [Online]. Available: https://izlik.org/JA62JX32EL
ISNAD
Kahraman, Hakan - Doğan, Hatice. “DİŞÇİ DELGİSİ GÜRÜLTÜSÜ İÇİN AKTİF GÜRÜLTÜ DENETLEYİCİ TASARIMI VE UYGULAMASI”. Dokuz Eylül Üniversitesi Mühendislik Fakültesi Fen ve Mühendislik Dergisi 20/59 (May 1, 2018): 555-565. https://izlik.org/JA62JX32EL.
JAMA
1.Kahraman H, Doğan H. DİŞÇİ DELGİSİ GÜRÜLTÜSÜ İÇİN AKTİF GÜRÜLTÜ DENETLEYİCİ TASARIMI VE UYGULAMASI. DEUFMD. 2018;20:555–565.
MLA
Kahraman, Hakan, and Hatice Doğan. “DİŞÇİ DELGİSİ GÜRÜLTÜSÜ İÇİN AKTİF GÜRÜLTÜ DENETLEYİCİ TASARIMI VE UYGULAMASI”. Dokuz Eylül Üniversitesi Mühendislik Fakültesi Fen Ve Mühendislik Dergisi, vol. 20, no. 59, May 2018, pp. 555-6, https://izlik.org/JA62JX32EL.
Vancouver
1.Hakan Kahraman, Hatice Doğan. DİŞÇİ DELGİSİ GÜRÜLTÜSÜ İÇİN AKTİF GÜRÜLTÜ DENETLEYİCİ TASARIMI VE UYGULAMASI. DEUFMD [Internet]. 2018 May 1;20(59):555-6. Available from: https://izlik.org/JA62JX32EL