In this study, thermal performance of plain finned-tube
evaporators in household refrigerators are investigated numerically and
experimentally. The design parameters affecting on the cooling capacity are
determined as air flowrate, evaporator temperature, tube alignment, number of tubes
and number of fins. In the initial stage, the effects of those parameters on
the cooling capacities are simulated by CoilDesigner software. The number of
experiments that are necessary to obtain correlations is determined by Minitab
software. The experiments are carried out in a no-frost household refrigerator
in the off-mode. At the end of each experiment, air side heat transfer
coefficients are calculated to generate a Nusselt (Nu) correlation as a
function of the mentioned design parameters. The generated correlation of the cooling
capacity can predict 95% of the experimental results within a confidence range
of 15%. The correlation of the cooling
capacity is converted to the Nusselt number correlation which is found to be
consistent with available data in literature. The experiments reveal that the
cooling capacity is dominantly affected by the evaporator temperature followed
by air flow rate, tube alignment, number of tubes and the number of fins.
Plain Finned Tube Evaporator Cooling Capacity Design of Experiments Nusselt Number Correlation Numerical Model
Bu çalışmada, düz kanatlı
|
Kanatlı Borulu Buharlaştıcı Soğutma Kapasitesi Deney Tasarımı Nusselt Sayısı Korelasyonu Sayısal Model
Primary Language | English |
---|---|
Journal Section | Research Article |
Authors | |
Publication Date | May 15, 2020 |
Published in Issue | Year 2020 |
Dokuz Eylül Üniversitesi, Mühendislik Fakültesi Dekanlığı Tınaztepe Yerleşkesi, Adatepe Mah. Doğuş Cad. No: 207-I / 35390 Buca-İZMİR.