In this study, the behaviour of axially loaded columns with and without steel fibers was
investigated experimentally and analytically. In the experimental part, 18 rectangular
reinforced concrete columns were tested under the axial load. Load carrying capacity and
axial load-strain relationships of the specimens were obtained. In the analytical part,
mathematical models (Saatcioglu and Ravzi, Sheikh and Uzumeri, Modified Kent and Park)
which were derived for axially loaded column were investigated. In addition, the analytical
solution which uses these mathematical models was carried out. Experimental and analytical
results were compared and obtained results were discussed.
Bu çalışmada, eksenel yük altındaki çelik lifli/fiberli ve lifsiz/fibersiz etriyeli betonarme kolonların davranışı, hem deneysel hem de analitik olarak incelenmiştir. Deneysel bölümde 18 adet dikdörtgen kesitli etriyeli betonarme kolon eksenel yük altında test edilmiştir. Deney numunelerinin taşıma güçleri ile eksenel yük-boyuna birim kısalma ilişkisi elde edilmiştir. Analitik çalışmada ise, malzeme için geliştirilmiş olan matematiksel modellerden Saatcioğlu ve Ravzi, Sheikh ve Üzümeri ile Geliştirilmiş Kent ve Park Modelleri ayrıntılı bir şekilde ele alınmış, hesap esasları verilmiştir. Ayrıca, söz konusu bu matematiksel modeller kullanılarak deney numunelerinin analitik çözümü yapılmıştır. Elde edilen deneysel ve analitik sonuçlar karşılaştırılarak irdelenmiştir
Other ID | JA78UC79ZC |
---|---|
Journal Section | Research Article |
Authors | |
Publication Date | January 1, 2006 |
Published in Issue | Year 2006 Volume: 8 Issue: 1 |
Dokuz Eylül Üniversitesi, Mühendislik Fakültesi Dekanlığı Tınaztepe Yerleşkesi, Adatepe Mah. Doğuş Cad. No: 207-I / 35390 Buca-İZMİR.