The importance of background correction during calculation of the major salivary gland function in salivary gland scintigraphy

Volume: 42 Number: 4 January 8, 2016

The importance of background correction during calculation of the major salivary gland function in salivary gland scintigraphy

Abstract

Objective: The aim of this study was to compare the parotid (P) and submandibular (SM) glands uptake and excretion ratios of 99mTc-pertechnetate, which were calculated by using the backgrounds drawn on five different areas.

Methods: Ninety-eight P and 98 SM glands of totally 48 patients were included in the study. 99mTc-pertechnetate salivary gland scintigraphy was performed in all patients. Oral stimulation with lemon juice was made at 15th minute of the imaging. The 99mTc-pertechnetate uptake and excretion ratios of the P and SM glands were calculated separately without using any background, and by using the backgrounds drawn on wide frontal, narrow frontal, temporal, cervical and shoulder regions. These values were statistically compared with each other in pairwise manner.

Results: The radioactivity uptake and excretion ratios of the P and SM glands calculated without using any background correction were statistically different from that calculated by using any background correction. In addition, the radioactivity uptake and excretion ratios of the P and SM glands calculated by using the backgrounds drawn on five different areas were mostly found statistically different from each other (p<0.05).

Conclusion: Background correction is important during the calculation of the uptake and excretion ratios of P and SM glands. This study demonstrates that calculated uptake and excretion ratios of P and SM glands may differ according to the used background area.

Key words: Salivary gland scintigraphy, parotid gland, submandibular gland, salivary gland function, background correction

Keywords

References

  1. Anjos DA, Etchebehere EC, Santos AO, et al. Normal values of [99mTc] pertechnetate uptake and excretion fraction by major salivary glands. Nucl Med Commun 2006;27:395-403.
  2. Yousem DM, Kraut MA, Chalian AA. Major salivary gland imaging. Radiology 2000;216:19-29.
  3. Afzelius P, Nielsen MY, Ewertsen C, Bloch KP. Imaging of the major salivary glands. Clin Physiol Funct Imaging 2014 Oct 16. doi: 10.1111/cpf.12199. [Epub ahead of print]
  4. Cheng SC, Wu VW, Kwong DL, Ying MT. Assessment of post-radiotherapy salivary glands. Br J Radiol.2011;84:393-402.
  5. Hays MT, Berman M. Pertechnetate distribution in man after
  6. intravenous infusion: a compartmental model. J Nucl Med
  7. ;18:898–904.
  8. de Rossi G, Focacci C. A computer-assisted method for semiquantitative assessment of salivary gland diseases. Eur J

Details

Primary Language

Turkish

Subjects

-

Journal Section

-

Authors

Zeki Dostbil This is me

İlhan Sezgin This is me

Publication Date

January 8, 2016

Submission Date

January 8, 2016

Acceptance Date

-

Published in Issue

Year 2015 Volume: 42 Number: 4

APA
Taşdemir, B., Dostbil, Z., & Sezgin, İ. (2016). The importance of background correction during calculation of the major salivary gland function in salivary gland scintigraphy. Dicle Medical Journal, 42(4), 459-466. https://doi.org/10.5798/diclemedj.0921.2015.04.0609
AMA
1.Taşdemir B, Dostbil Z, Sezgin İ. The importance of background correction during calculation of the major salivary gland function in salivary gland scintigraphy. Dicle Medical Journal. 2016;42(4):459-466. doi:10.5798/diclemedj.0921.2015.04.0609
Chicago
Taşdemir, Bekir, Zeki Dostbil, and İlhan Sezgin. 2016. “The Importance of Background Correction During Calculation of the Major Salivary Gland Function in Salivary Gland Scintigraphy”. Dicle Medical Journal 42 (4): 459-66. https://doi.org/10.5798/diclemedj.0921.2015.04.0609.
EndNote
Taşdemir B, Dostbil Z, Sezgin İ (January 1, 2016) The importance of background correction during calculation of the major salivary gland function in salivary gland scintigraphy. Dicle Medical Journal 42 4 459–466.
IEEE
[1]B. Taşdemir, Z. Dostbil, and İ. Sezgin, “The importance of background correction during calculation of the major salivary gland function in salivary gland scintigraphy”, Dicle Medical Journal, vol. 42, no. 4, pp. 459–466, Jan. 2016, doi: 10.5798/diclemedj.0921.2015.04.0609.
ISNAD
Taşdemir, Bekir - Dostbil, Zeki - Sezgin, İlhan. “The Importance of Background Correction During Calculation of the Major Salivary Gland Function in Salivary Gland Scintigraphy”. Dicle Medical Journal 42/4 (January 1, 2016): 459-466. https://doi.org/10.5798/diclemedj.0921.2015.04.0609.
JAMA
1.Taşdemir B, Dostbil Z, Sezgin İ. The importance of background correction during calculation of the major salivary gland function in salivary gland scintigraphy. Dicle Medical Journal. 2016;42:459–466.
MLA
Taşdemir, Bekir, et al. “The Importance of Background Correction During Calculation of the Major Salivary Gland Function in Salivary Gland Scintigraphy”. Dicle Medical Journal, vol. 42, no. 4, Jan. 2016, pp. 459-66, doi:10.5798/diclemedj.0921.2015.04.0609.
Vancouver
1.Bekir Taşdemir, Zeki Dostbil, İlhan Sezgin. The importance of background correction during calculation of the major salivary gland function in salivary gland scintigraphy. Dicle Medical Journal. 2016 Jan. 1;42(4):459-66. doi:10.5798/diclemedj.0921.2015.04.0609

Cited By