Electric and Magnetic Field Analysis for a 34.5 kV Transformer Under Composite Voltage Conditions: COMSOL Multiphysics Simulation
Abstract
Keywords
Composite voltage, Electric field analysis, Magnetic flux density, COMSOL Multiphysics, Lightning impulse voltage
References
- [1] J. Sun, Q. Yang, P. Su, S. Wu, S. Chen and L. He, “Diagnosis of winding fault in three-winding transformer using lightning impulse voltage,” Electric Power Systems Research, vol. 175, 2019, Art. no. 105898.
- [2] X. Zhang, H. Wang, R. Guo, Z. Zhang, J. Li and X. Han, “Fault diagnosis technologies for power transformers during the on-site inductive oscillating switching impulse voltage withstand test,” IET Generation, Transmission and Distribution, vol. 16, no. 19, pp. 3894–3905, 2022.
- [3] M. Florkowski, J. Furgal, M. Kuniewski and P. Pajak, “Comparison of transformer winding responses to standard lightning impulses and operational overvoltages,” IEEE Transactions on Dielectrics and Electrical Insulation, vol. 25, no. 3, pp. 965–974, 2018.
- [4] E. Tunç and M. Fidan, "Residual Voltage Tests of 4.5 kV Metal Oxide Surge Arrester," in 2023 14th International Conference on Electrical and Electronics Engineering (ELECO), Bursa, Türkiye, 2023, pp. 1-5.
- [5] R. R. Annadi and C. S. Patsa, “Estimation of switching surge flashover rate of 1200-kV UHVAC transmission line considering switching overvoltage waveshape,” Electrical Engineering, vol. 102, no. 2, pp. 953–966, 2020.
- [6] Y. Zheng, B. Yu, H. Xu, D. Yan, X. Li and W. He, “Novel method for restraining 35 kV shunt reactor switching overvoltage – phase controlled breaker,” The Journal of Engineering, vol. 2019, no. 16, pp. 742–747, 2019.
- [7] E. Tunc and M. Fidan, “Experimental and simulation study of pulse current generator,” Electric Power Components and Systems, vol. 52, no. 8, pp. 1316–1327, 2024.
- [8] L. F. Freitas-Gutierres et al., “Framework for decision-making in preventive maintenance: Electric field analysis and partial discharge diagnosis of high-voltage insulators,” Electric Power Systems Research, vol. 233, 2024, Art. no. 110447.
- [9] M. Fidan and H. İsmailoǧlu, “CuSO45H2O sıvı direncin harmonikli ve harmoniksiz yüksek gerilim altında kismi boşalma davranışları,” Journal of the Faculty of Engineering and Architecture of Gazi University, vol. 32, no. 1, pp. 315–323, 2017.
- [10] Y. Özüpak, “Ansys@maxwell kullanılarak transformatörlerin ani akımlar durumunda meydana gelen elektrik alan analizlerinin gerçekleştirilmesi,” Adıyaman Üniversitesi Mühendislik Bilimleri Dergisi, vol. 8, no. 14, pp. 105–116, 2021.