Year 2020, Volume 8 , Issue 2, Pages 1307 - 1318 2020-04-30

Experimental Analysis of Energy Quality at Campus Network-Case Study: Bolu Abant Izzet Baysal University (Engineering Building)
Kampüs Şebekesinde Enerji Kalitesinin Deneysel Olarak Analizi- Örnek Çalışma: Bolu Abant İzzet Baysal Üniversitesi (Mühendislik Binası)

Erdal BEKİROĞLU [1] , Haluk YILDIZ [2]


In this study energy quality of university campus network have been analyzed experimentally. The experimental tests and measurements have been implemented at Engineering Building of the Bolu Abant Izzet Baysal University (Turkey). Energy quality analysis has been performed by making current, voltage, frequency, power factor, harmonics, neutral-earth voltage measurements at the main distribution board of the Engineering Building. Besides, active power filter has been connected and its effects examined. The reasons for the energy quality problems on the electric power distribution system of the campus building have been revealed and required solutions have been offered

Bu çalışmada üniversite kampüsü şebekesinin enerji kalitesi deneysel olarak analiz edilmiştir. Deneysel testler ve ölçümler Bolu Abant İzzet Baysal Üniversitesi Mühendislik binasında gerçekleştirilmiştir. Mühendislik binasının ana dağıtım panosunda akım, gerilim, frekans, güç faktörü, harmonikler, nötr-toprak gerilim ölçümleri yapılarak enerji kalitesi analizi yapılmıştır. Ayrıca, aktif güç filtresi bağlanmış ve etkileri incelenmiştir. Kampüs elektrik dağıtım sistemindeki binaların enerji kalitesi sorunlarının nedenleri ortaya konulmuş ve gerekli çözümler sunulmuştur.

  • [1] V. Kavitha and K. Subramanian “Investigation of power issues and its solution for distributed power system,” Int. Conf. on Circuit, Power and Computing Technologies (ICCPCT), Kollam, 2017, pp. 1-6, doi. 10.1109/ICCPCT.2017.8074372.
  • [2] Ch, Y., Goswami, SK., & Chatterjee, D. 2016, “Effect of network reconfiguration on power quality of distribution system,” International Journal of Electrical Power&Energy Systems, vol. 83, pp. 87-95.
  • [3] V.N. Tulsky, A.S. Vanin, M.A. Tolba, A.Y. Sharova and A.A. Z. Diab,”Study and analysis of power quality for an electric power distribution system-Case study: Moscow region,” IEEE NW Russia Young Researchers in Electrical and Electronic Engineering Conference (ElConRusNW), St. Petersburg, 2016, pp. 710-716.
  • [4] J. Wang, H. Li, L. Feng, L. Xu, X. Lv and Y. Xu, “Analysis of power quality issues of electrified railway,” 8th Int. Conf. on Mechanical and Intelligent Manufacturing Technologies (ICMIMT), Cape Town, 2017, doi. 10.1109/ICMIMT.2017.7917459.
  • [5] D. Robescu, G.C. Lazaroiu and C. Bulac, “Power quality and energy effiency analysis in a wastewater treatment plant,” 16th Int. Conf. on Harmonics and Quality of Power (ICHQP), Bucharest, 2014, doi. 10.1109/ICHQP.2014.6842893.
  • [6] L. Chenyi, X. Lei, H. Shuilian, Z. Hengdong and F. Xiaobo “Research of comprehensive application of intelligent low-voltage power distribution units in improving quality,” China Int. Conf. on Electricity Distribution (CICED), Tianjin, 2018, doi. 10.1109/CICED.2018.8592208.
  • [7] N.V. Savina, Y.V. Myasoedov and L.A. Myasoedova, “Influence of quality of the electric energy on reliability of electrical supply systems,” Int. Multi-Conference on Industrial Engineering and Modern Technologies (FarEastCon), Vladivostok, 2018, doi. 10.1109/FarEastCon.2018.8602690.
  • [8] Xie, D., Yu, L., Jiang, T. & Zou, Y. 2018, “Distributed energy optimization for HVAC systems in university campus buildings,” IEEE Access, vol. 6, pp. 59141-59151.
  • [9] R. Singh and A. Singh “Energy loss due to harmonics in residential campus-A case study,” 45th International Universities Power Engineering Conference (UPEC2010), Cardiff, 2010.
  • [10] K.M. Alawasa and A.I. Al-Odienat “Harmonics assessment and analysis at low voltage networks-Case study: Mutah university campus (Engineering Building),” The 10th Jordan Int. Electrical and Electronics Engineering Conf., Amman, 2017, doi. 10.1109/JIEEEC.2017.8051407.
  • [11] A. Ruviaro, M. Sperandio, P. Ebert and M.A.F Boaski, “Energy efficiency studies in a Brazilian University Campus,” IEEE PES Transmission Distribution Conference and Exhibition, 2018, Lima, doi. 10.1109/TDC-LA.2018.8511781.
  • [12] H. Yıldız, “BAİBÜ Merkez kampüs elektrik enerji dağıtım sisteminin enerji verimliliği ve enerji kalitesi açısından incelenmesi,” Yüksek Lisans tezi, Elektrik Elektronik Mühendisliği Bölümü, Bolu Abant İzzet Baysal Üniversitesi, Bolu, Türkiye, 2019.
Primary Language en
Subjects Engineering
Journal Section Articles
Authors

Orcid: 0000-0002-1821-0722
Author: Erdal BEKİROĞLU (Primary Author)
Institution: ABANT IZZET BAYSAL UNIVERSITY
Country: Turkey


Orcid: 0000-0002-0358-318X
Author: Haluk YILDIZ
Institution: ABANT IZZET BAYSAL UNIVERSITY
Country: Turkey


Thanks We would like to thank the rectorate of Bolu Abant Izzet Baysal University for allowing this study to be carried out at main campus.
Dates

Publication Date : April 30, 2020

Bibtex @research article { dubited648204, journal = {Düzce Üniversitesi Bilim ve Teknoloji Dergisi}, issn = {}, eissn = {2148-2446}, address = {}, publisher = {Duzce University}, year = {2020}, volume = {8}, pages = {1307 - 1318}, doi = {10.29130/dubited.648204}, title = {Experimental Analysis of Energy Quality at Campus Network-Case Study: Bolu Abant Izzet Baysal University (Engineering Building)}, key = {cite}, author = {Beki̇roğlu, Erdal and Yıldız, Haluk} }
APA Beki̇roğlu, E , Yıldız, H . (2020). Experimental Analysis of Energy Quality at Campus Network-Case Study: Bolu Abant Izzet Baysal University (Engineering Building) . Düzce Üniversitesi Bilim ve Teknoloji Dergisi , 8 (2) , 1307-1318 . DOI: 10.29130/dubited.648204
MLA Beki̇roğlu, E , Yıldız, H . "Experimental Analysis of Energy Quality at Campus Network-Case Study: Bolu Abant Izzet Baysal University (Engineering Building)" . Düzce Üniversitesi Bilim ve Teknoloji Dergisi 8 (2020 ): 1307-1318 <https://dergipark.org.tr/en/pub/dubited/issue/55096/648204>
Chicago Beki̇roğlu, E , Yıldız, H . "Experimental Analysis of Energy Quality at Campus Network-Case Study: Bolu Abant Izzet Baysal University (Engineering Building)". Düzce Üniversitesi Bilim ve Teknoloji Dergisi 8 (2020 ): 1307-1318
RIS TY - JOUR T1 - Experimental Analysis of Energy Quality at Campus Network-Case Study: Bolu Abant Izzet Baysal University (Engineering Building) AU - Erdal Beki̇roğlu , Haluk Yıldız Y1 - 2020 PY - 2020 N1 - doi: 10.29130/dubited.648204 DO - 10.29130/dubited.648204 T2 - Düzce Üniversitesi Bilim ve Teknoloji Dergisi JF - Journal JO - JOR SP - 1307 EP - 1318 VL - 8 IS - 2 SN - -2148-2446 M3 - doi: 10.29130/dubited.648204 UR - https://doi.org/10.29130/dubited.648204 Y2 - 2020 ER -
EndNote %0 Düzce Üniversitesi Bilim ve Teknoloji Dergisi Experimental Analysis of Energy Quality at Campus Network-Case Study: Bolu Abant Izzet Baysal University (Engineering Building) %A Erdal Beki̇roğlu , Haluk Yıldız %T Experimental Analysis of Energy Quality at Campus Network-Case Study: Bolu Abant Izzet Baysal University (Engineering Building) %D 2020 %J Düzce Üniversitesi Bilim ve Teknoloji Dergisi %P -2148-2446 %V 8 %N 2 %R doi: 10.29130/dubited.648204 %U 10.29130/dubited.648204
ISNAD Beki̇roğlu, Erdal , Yıldız, Haluk . "Experimental Analysis of Energy Quality at Campus Network-Case Study: Bolu Abant Izzet Baysal University (Engineering Building)". Düzce Üniversitesi Bilim ve Teknoloji Dergisi 8 / 2 (April 2020): 1307-1318 . https://doi.org/10.29130/dubited.648204
AMA Beki̇roğlu E , Yıldız H . Experimental Analysis of Energy Quality at Campus Network-Case Study: Bolu Abant Izzet Baysal University (Engineering Building). DÜBİTED. 2020; 8(2): 1307-1318.
Vancouver Beki̇roğlu E , Yıldız H . Experimental Analysis of Energy Quality at Campus Network-Case Study: Bolu Abant Izzet Baysal University (Engineering Building). Düzce Üniversitesi Bilim ve Teknoloji Dergisi. 2020; 8(2): 1307-1318.