Design of Electronic Data Acquisiton Unit for Laser Tomography System
Abstract
In this work design of electronic data cquisition unit for Laser Tomography (LT) system has been represented. Electronic hardware, Embedded software, PC interface programs have been developed for this purpose. 850 nm 20 mW laser source has been used to test the device validity check. General purpose photodiode acquired required back reflected laser light. 6 different integration times has been used for data acquistion test. 10 microseconds to 300 microseconds integration times were specific test criteria. 10 microseconds integration time resolution has been achieved. Pic18f2550 microcontroller (Microchip, Boise, ID) has been used to control the device main board and for data transfer process. DDC112 analog current input digital voltage output analog to digital converter (ADC) Burr-Brown products of Texas Instruments integrated circuit has been used for data conversion purpose. The device has been tested on left arm by laser source and general purpose pn photodiode.
Keywords
References
- [1] Kazanci H.O., Mercan T., Canpolat M., "Design and evaluation of a reflectance diffuse optical tomography system," Optical and Quantum Electronıcs, vol.47, no.2, pp.257-265, 2014.
- [2] Kazanci H.O., Canpolat M., "Continuous Wave Diffuse Optical Tomography System with High Resolution Current to Voltage Analog Digital Converter ," El-Cezeri Journal of Science and Engineering, vol.2, no.1, pp.68-77, 2015.
- [3] Canpolat M., Kazanci H.O., Mercan T., Alimoğlu E., "Design of Breast Laser Tomography System and Pilot Clinical Results ," Akdeniz tıp dergisi, cilt.1, no.1, ss.58-63, 2015.
- [4] Mercan T., Kazanci H.O., Canpolat M., "Diffuse Optical Tomography System Design And Reconstruction Of Tail Fat Of Sheep As A Breast Phantom," SPIE Photonics West Optical Tomography and Spectroscopy of Tissue XI, San-Francisco, US, vol.9319, pp.80-80, Feb. 7- 12 2015.
- [5] Canpolat M., Mercan T., Sevimli G., Alimoğlu E., Kazanci H.O., "Meme Lazer Diffüz Optik Tomografi Sisteminin Geliştirilmesi ve Pilot Klinik Deney Sonuçları," 27. National Biophysic Congress , Malatya, Turkey, pp.11-14, 29 Sep. - 3 Oct. 2015.
- [6] Canpolat M., Kazanci H.O., Mercan T., "Developing And Testing A Multi-Source And Detector Reflectance Diffuse Optical Tomography System," SPIE Photonics West, SanFrancisco, US, pp.216-216, Feb. 1-6 2014.
- [7] Kazanci H.O., Mercan T., Canpolat M., "Lazer Meme Tomografi Sisteminin Geliştirilmesi Ve In-Vitro Deneyler," 26. National Biophysics Congress, Tokat, Turkey, 9-12 Sep. 2014.
- [8] Burr Brown Products from Texas Instruments, "Dual Current Input 20-Bit Analog To Dıgıtal Converter", SBAS085B January 2000 revised October 2004.
Details
Primary Language
English
Subjects
Engineering
Journal Section
Research Article
Publication Date
January 31, 2017
Submission Date
January 13, 2016
Acceptance Date
-
Published in Issue
Year 2017 Volume: 4 Number: 1
