The impact of high gain conventional hearingaid aid on OAEs in a case of auditory neuropathy/ dys-synchrony

Volume: 15 Number: 1 January 15, 2013
  • Piyali Kundu
  • Nachiketa Rout
EN

The impact of high gain conventional hearingaid aid on OAEs in a case of auditory neuropathy/ dys-synchrony

Abstract

Abstract. Aim of the study is to focus on the impact of high gain hearing aid on outer hair cells’ functioning as reflected by otoacoustic emission (OAE) changes. A child diagnosed as bilateral moderate -moderately severe sensori neural hearing loss with primary auditory neuropathy / dys-synchrony (AN/ AD) was referred to AYJNIHH (ERC) after being fitted with high gain hearing aid. She had used the hearing aid for less than a year. Audiological evaluation at AYJNIHH (ERC) was indicative of moderate to moderately severe hearing loss with absence of distortion product otoacoustic emissions (DPOAE). She was recommended to discontinue the use of the hearing aid for a couple of weeks. Auditory brainstem response (ABR) and OAE was administered after 14 days. No identifiable peak V was obtained in both the ears however the case had emissions on DPOAE. She was fitted a mild class hearing aid and included for speech language therapy. Conservative trials with amplification devices, diligent monitoring of amplification output levels and OAEs along with possibilities of a cochlear implant was to be explored during therapy. The primary reason behind deterioration in DPOAE may be temporary physiological changes resulting in temporary threshold shift. Therefore, high quality, low gain, wide dynamic range compression hearing aids may be the probable cause of return back of OAEs following two weeks without amplification. Amplification may contribute to loss of OAEs and the risk from use of amplification must be weighed against the benefits of amplification provided to the client.

Key words: Otoacoustic emissions, auditory neuropathy, outer hair cells’, ABR, temporary threshold shift.

Keywords

References

  1. Davis H, Hirsh S. A slow brainstem response for low frequency audiometry. Audiology 1979; 18: 461.
  2. Worthington D, Peters J. Quantifiable hearing and no ABR: Paradox or error? Ear and Hearing 1980; : 281-285.
  3. Lenhardt M. Childhood central processing disorder with brainstem evoked response verification. Archives of Otolaryngology 1981; 107: 623-625.
  4. Krovs N. Auditory neuropathy:An historical and current perspective.In: Sininger Y, starr A (end). Auditory neuropathy: A new perspective on hearing disorders. Canada: Sıngular-Thomson hearnıng ; pp 233-250
  5. Berlin, C.I., Hood, L.J. & Rose, K. On renaming auditory neuropathy as auditory dys- synchrony. Audiol Today 2001; 13: 15-17.
  6. Starr, A., Picton, T.W., Sininger, Y.S., Hood, L.J. & Berlin, C.I. n. Brain 1996; 119(3): 741-753.
  7. Rance, G., McKay, C. & Grayden, D. Perceptual characterization of children with auditory neuropathy. Ear Hear 2004; 25: 34-46.
  8. Zeng, F.G., Kong, Y.Y., Michaelewski, H.J. & Starr, A. Perceptual consequences of disrupted auditory nerve activity. J Neurophysiol 2005; 93 (3050): 203-232. 3063.

Details

Primary Language

English

Subjects

-

Journal Section

-

Authors

Piyali Kundu This is me

Nachiketa Rout This is me

Publication Date

January 15, 2013

Submission Date

January 15, 2013

Acceptance Date

-

Published in Issue

Year 2010 Volume: 15 Number: 1

APA
Kundu, P., & Rout, N. (2013). The impact of high gain conventional hearingaid aid on OAEs in a case of auditory neuropathy/ dys-synchrony. EASTERN JOURNAL OF MEDICINE, 15(1), 26-30. https://izlik.org/JA32UR83ZB
AMA
1.Kundu P, Rout N. The impact of high gain conventional hearingaid aid on OAEs in a case of auditory neuropathy/ dys-synchrony. EASTERN JOURNAL OF MEDICINE. 2013;15(1):26-30. https://izlik.org/JA32UR83ZB
Chicago
Kundu, Piyali, and Nachiketa Rout. 2013. “The Impact of High Gain Conventional Hearingaid Aid on OAEs in a Case of Auditory Neuropathy Dys-Synchrony”. EASTERN JOURNAL OF MEDICINE 15 (1): 26-30. https://izlik.org/JA32UR83ZB.
EndNote
Kundu P, Rout N (March 1, 2013) The impact of high gain conventional hearingaid aid on OAEs in a case of auditory neuropathy/ dys-synchrony. EASTERN JOURNAL OF MEDICINE 15 1 26–30.
IEEE
[1]P. Kundu and N. Rout, “The impact of high gain conventional hearingaid aid on OAEs in a case of auditory neuropathy/ dys-synchrony”, EASTERN JOURNAL OF MEDICINE, vol. 15, no. 1, pp. 26–30, Mar. 2013, [Online]. Available: https://izlik.org/JA32UR83ZB
ISNAD
Kundu, Piyali - Rout, Nachiketa. “The Impact of High Gain Conventional Hearingaid Aid on OAEs in a Case of Auditory Neuropathy Dys-Synchrony”. EASTERN JOURNAL OF MEDICINE 15/1 (March 1, 2013): 26-30. https://izlik.org/JA32UR83ZB.
JAMA
1.Kundu P, Rout N. The impact of high gain conventional hearingaid aid on OAEs in a case of auditory neuropathy/ dys-synchrony. EASTERN JOURNAL OF MEDICINE. 2013;15:26–30.
MLA
Kundu, Piyali, and Nachiketa Rout. “The Impact of High Gain Conventional Hearingaid Aid on OAEs in a Case of Auditory Neuropathy Dys-Synchrony”. EASTERN JOURNAL OF MEDICINE, vol. 15, no. 1, Mar. 2013, pp. 26-30, https://izlik.org/JA32UR83ZB.
Vancouver
1.Piyali Kundu, Nachiketa Rout. The impact of high gain conventional hearingaid aid on OAEs in a case of auditory neuropathy/ dys-synchrony. EASTERN JOURNAL OF MEDICINE [Internet]. 2013 Mar. 1;15(1):26-30. Available from: https://izlik.org/JA32UR83ZB