Abstract

In this study, the radiation dose rates emitted by patients who underwent dacryoscintigraphy imaging were determined. For this, the radiation dose rate was measured at the 8.23, 41.68 and 56.81 minutes after the injection of the radiopharmaceutical. In addition, 12 points were determined from the front of the patient. these points are 25, 50, 100 and 200 cm from the head level, 25, 50, 100, and 200 cm from the chest level and 25, 50, 100 and 200 cm from the foot level. 36 different measurements were made from one patient, at 3 different times, from these points. As a result of the measurements, the average dose rate varies according to time and measurement point and was found between 0.22 µSh-1 and 2.86 µSh-1.

Keywords

References

  1. Bera G, Soret M, Maisonobe JA, Giron A, Garnier JM, Habert MO, Kas A (2018) Equivalent dose rate from patients after whole body FDG-PET/CT. Médecine Nucléaire 42(1):45–48. https://doi.org/10.1016/j.mednuc.2017.11.003
  2. Cronin B, Marsden PK, O’Doherty MJ (1999) Are restrictions to behaviour of patients required following fuorine-18 fuorode oxyglucose positron emission tomographic studies? Eur J Nucl Med 26:121–128. https://doi.org/10.1007/s002590050367
  3. Demir M, Demir B, Sayman H, Sager S, Sabbir Ahmed A, Uslu I (2011) Radiation protection for accompanying person and radiation workers in PET/CT. Radiat Prot Dosim 147:528–532. https ://doi.org/10.1093/rpd/ncq497
  4. Detorakis, E. T., Zissimopoulos, A., Ioannakis, K., & Kozobolis, V. P. (2014). Lacrimal outflow mechanisms and the role of scintigraphy: current trends. World Journal of Nuclear Medicine, 13(1), 16.
  5. Herzig, S., & Hurwitz, J. J. (1979). Lacrimal sac calculi. Canadian journal of ophthalmology. Journal canadien d'ophtalmologie, 14(1), 17-20.
  6. Günay, O., & Abamor, E. (2019). Environmental radiation dose rate arising from patients of PET/CT. International Journal of Environmental Science and Technology, 16(9), 5177-5184.
  7. Günay, O., Sarıhan, M., Abamor, E., & Yarar, O. (2019). Environmental radiation doses from patients undergoing Tc-99m DMSA cortical renal scintigraphy. International Journal of Computational and Experimental Science and Engineering (IJCESEN), 5(2), 86-93.
  8. Günay, O., Sarıhan, M., Yarar, O., Abuqbeitah, M., Demir, M., Sönmezoğlu, K., ... & Gündoğdu, Ö. (2019). Determination of radiation dose from patients undergoing Tc-99m Sestamibi nuclear cardiac imaging. International Journal of Environmental Science and Technology, 16(9), 5251-5258.

Details

Primary Language

English

Subjects

Engineering

Journal Section

Research Article

Publication Date

May 7, 2022

Submission Date

April 6, 2022

Acceptance Date

April 16, 2022

Published in Issue

Year 2022 Number: 35

APA
Sarıhan, M., Günay, O., Yarar, O., & Demir, Ph.d., M. (2022). Determination of the Radiation Dose Level Emitted to the Environment in Patients Undergoing Dacryo Scintigraphy. Avrupa Bilim Ve Teknoloji Dergisi, 35, 625-632. https://doi.org/10.31590/ejosat.1099508