In this study, DP 1000 (Dual Phase) steel plates having 1.2 mm
thickness were joined by copper-based (CuAl8) wire in CMT-brazing (Cold Metal
Transfer) technique. Specimens were prepared in joining forms as butt joint.
CMT-Brazing operations were done with nine different CMT-Brazing current intensity of 40, 45, 50, 55, 60, 65, 70, 75
and 80 A. CuAl8 wire composed largely of copper serves as the filler
metal were used. Having accomplished the CMT-brazing operations; tensile
properties of joints were detected, and micro and macro-structures of joints
were investigated in order to see the joinability of DP 1000 steel by
CMT-brazing technique.
In this study, DP 1000 (Dual Phase) steel plates having 1.2 mm thickness were joined by copper-based (CuAl8) wire in CMT-brazing
(Cold Metal Transfer) technique. Specimens were prepared in joining forms as butt joint. CMT-Brazing operations were done with
nine different CMT-Brazing current intensity of 40, 45, 50, 55, 60, 65, 70, 75 and 80 A. CuAl8 wire composed largely of copper
serves as the filler metal were used. Having accomplished the CMT-brazing operations; tensile properties of joints were detected, and
micro and macro-structures of joints were investigated in order to see the joinability of DP 1000 steel by CMT-brazing technique.
Primary Language | English |
---|---|
Subjects | Engineering |
Journal Section | Articles |
Authors | |
Publication Date | December 31, 2017 |
Published in Issue | Year 2017 Issue: Özel Sayı - Special Issue |