Intermittency and Inflexibility Blister Pump Impress Factors

Volume: 1 Number: 2 August 1, 2011
  • Boštjan Mlakar
  • Cvetko Zupančič
EN

Intermittency and Inflexibility Blister Pump Impress Factors

Abstract

Divisional centralized heating and cooling system, cogeneratton system of heat and power and power-gas cogeneration system. In order to further fully and reasonably use the heat in doubleeffect absorption units, double-stage bubble pump must be involved in the adoption o u pump replacing the traditional mechanical solution pump. It was designed a secon generator based on a solar pump-free lithium bromide absorption chiller system. The expenmen adopts the lunate thermosiphon elevation tube, effectively improves the solar energy utility efficiency by decreasing the temperature of heat source. It is established a theoretical model of the bubble pump and took a lot of researches on the impact factors of the bubble pump such as heat input, immersion height and others. Despite there are many thorough reports on single-stage bubble pump, the double-stage bubble pump has been rarely discussed. This study build an experimental apparatus of double-stage bubble pump and use water and different concentrations of lithium bromide solutions as working fluid to study relevant characteristics of double-stage bubble pump. Intermittent operation probably occurs during the running of double-stage bubble pump. Studies of the double-stage bubble pump on its running intermittence and stability and influencing factors will believably provide an important reference in its production and application

Keywords

Details

Primary Language

English

Subjects

-

Journal Section

-

Authors

Boštjan Mlakar This is me

Cvetko Zupančič This is me

Publication Date

August 1, 2011

Submission Date

August 1, 2011

Acceptance Date

-

Published in Issue

Year 2011 Volume: 1 Number: 2

APA
Mlakar, B., & Zupančič, C. (2011). Intermittency and Inflexibility Blister Pump Impress Factors. European Journal of Technique (EJT), 1(2). https://izlik.org/JA77WS98FW
AMA
1.Mlakar B, Zupančič C. Intermittency and Inflexibility Blister Pump Impress Factors. EJT. 2011;1(2). https://izlik.org/JA77WS98FW
Chicago
Mlakar, Boštjan, and Cvetko Zupančič. 2011. “Intermittency and Inflexibility Blister Pump Impress Factors”. European Journal of Technique (EJT) 1 (2). https://izlik.org/JA77WS98FW.
EndNote
Mlakar B, Zupančič C (August 1, 2011) Intermittency and Inflexibility Blister Pump Impress Factors. European Journal of Technique (EJT) 1 2
IEEE
[1]B. Mlakar and C. Zupančič, “Intermittency and Inflexibility Blister Pump Impress Factors”, EJT, vol. 1, no. 2, Aug. 2011, [Online]. Available: https://izlik.org/JA77WS98FW
ISNAD
Mlakar, Boštjan - Zupančič, Cvetko. “Intermittency and Inflexibility Blister Pump Impress Factors”. European Journal of Technique (EJT) 1/2 (August 1, 2011). https://izlik.org/JA77WS98FW.
JAMA
1.Mlakar B, Zupančič C. Intermittency and Inflexibility Blister Pump Impress Factors. EJT. 2011;1. Available at https://izlik.org/JA77WS98FW.
MLA
Mlakar, Boštjan, and Cvetko Zupančič. “Intermittency and Inflexibility Blister Pump Impress Factors”. European Journal of Technique (EJT), vol. 1, no. 2, Aug. 2011, https://izlik.org/JA77WS98FW.
Vancouver
1.Boštjan Mlakar, Cvetko Zupančič. Intermittency and Inflexibility Blister Pump Impress Factors. EJT [Internet]. 2011 Aug. 1;1(2). Available from: https://izlik.org/JA77WS98FW

All articles published by EJT are licensed under the Creative Commons Attribution 4.0 International License. This permits anyone to copy, redistribute, remix, transmit and adapt the work provided the original work and source is appropriately cited.Creative Commons Lisansı