Intermittency and Inflexibility Blister Pump Impress Factors

Cilt: 1 Sayı: 2 1 Ağustos 2011
  • Boštjan Mlakar
  • Cvetko Zupančič
PDF İndir
EN

Intermittency and Inflexibility Blister Pump Impress Factors

Öz

Divisional centralized heating and cooling system, cogeneratton system of heat and power and power-gas cogeneration system. In order to further fully and reasonably use the heat in doubleeffect absorption units, double-stage bubble pump must be involved in the adoption o u pump replacing the traditional mechanical solution pump. It was designed a secon generator based on a solar pump-free lithium bromide absorption chiller system. The expenmen adopts the lunate thermosiphon elevation tube, effectively improves the solar energy utility efficiency by decreasing the temperature of heat source. It is established a theoretical model of the bubble pump and took a lot of researches on the impact factors of the bubble pump such as heat input, immersion height and others. Despite there are many thorough reports on single-stage bubble pump, the double-stage bubble pump has been rarely discussed. This study build an experimental apparatus of double-stage bubble pump and use water and different concentrations of lithium bromide solutions as working fluid to study relevant characteristics of double-stage bubble pump. Intermittent operation probably occurs during the running of double-stage bubble pump. Studies of the double-stage bubble pump on its running intermittence and stability and influencing factors will believably provide an important reference in its production and application

Anahtar Kelimeler

Ayrıntılar

Birincil Dil

İngilizce

Konular

-

Bölüm

-

Yazarlar

Boštjan Mlakar Bu kişi benim

Cvetko Zupančič Bu kişi benim

Yayımlanma Tarihi

1 Ağustos 2011

Gönderilme Tarihi

1 Ağustos 2011

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 2011 Cilt: 1 Sayı: 2

Kaynak Göster

APA
Mlakar, B., & Zupančič, C. (2011). Intermittency and Inflexibility Blister Pump Impress Factors. European Journal of Technique (EJT), 1(2). https://izlik.org/JA77WS98FW
AMA
1.Mlakar B, Zupančič C. Intermittency and Inflexibility Blister Pump Impress Factors. EJT. 2011;1(2). https://izlik.org/JA77WS98FW
Chicago
Mlakar, Boštjan, ve Cvetko Zupančič. 2011. “Intermittency and Inflexibility Blister Pump Impress Factors”. European Journal of Technique (EJT) 1 (2). https://izlik.org/JA77WS98FW.
EndNote
Mlakar B, Zupančič C (01 Ağustos 2011) Intermittency and Inflexibility Blister Pump Impress Factors. European Journal of Technique (EJT) 1 2
IEEE
[1]B. Mlakar ve C. Zupančič, “Intermittency and Inflexibility Blister Pump Impress Factors”, EJT, c. 1, sy 2, Ağu. 2011, [çevrimiçi]. Erişim adresi: https://izlik.org/JA77WS98FW
ISNAD
Mlakar, Boštjan - Zupančič, Cvetko. “Intermittency and Inflexibility Blister Pump Impress Factors”. European Journal of Technique (EJT) 1/2 (01 Ağustos 2011). https://izlik.org/JA77WS98FW.
JAMA
1.Mlakar B, Zupančič C. Intermittency and Inflexibility Blister Pump Impress Factors. EJT. 2011;1. Available at https://izlik.org/JA77WS98FW.
MLA
Mlakar, Boštjan, ve Cvetko Zupančič. “Intermittency and Inflexibility Blister Pump Impress Factors”. European Journal of Technique (EJT), c. 1, sy 2, Ağustos 2011, https://izlik.org/JA77WS98FW.
Vancouver
1.Boštjan Mlakar, Cvetko Zupančič. Intermittency and Inflexibility Blister Pump Impress Factors. EJT [Internet]. 01 Ağustos 2011;1(2). Erişim adresi: https://izlik.org/JA77WS98FW