CONDENSATION ANALYSIS OF THE INSULATION OF WALLS ACCORDING TO DIFFERENT LOCATIONS IN MARDIN PROVINCE
Abstract
In
this study, condensation and vapor diffusion caused by different positioned
insulation in the wall for Mardin province were analyzed. In the analysis,
according to 2008 standard of TS 825, Glaser graphing method and graphical user
interface (GUI) were used in MATLAB. Extruded polyurethane foam was used as the
insulation material and normal unreinforced concrete was selected as the wall.
Evaporation and condensation amounts were determined by creating 6 different
wall models with the same insulation thickness of 20 cm thick and unreinforced
concrete wall covered with 2 cm plaster on the inside and 3 cm thickness on the
outside. The data obtained for 2 cm and 4 cm insulation thicknesses are
presented in tables and the results are interpreted for Mardin province. As a
result, it was seen that the worst wall structure in terms of condensation and
evaporation was obtained in the middle insulated wall and later in the interior
insulated wall structure. The externally insulated wall showed no condensation.
Keywords
References
- [1] Heperkan H.A., Bircan M.M., Sevindir M.K. (2001). Vapor diffusion and condensation in building materials, V. National Installation Engineering Congress and Exhibition, İzmir, TURKEY, 461-469
- [2] Umaroğulları F., Zorer Gedik, G., Mıhlayanlar, E. (2011). Condensation Control of Insulated and Uninsulated Concrete Walls in the Periodic Regime: The Case of Edirne. megaronjournal, 6(1), 13-20
- [3] Kavas, E., Thermal Protected Wall Sections in Eastern Anatolia Region and Condensation Control (Erzurum Case), Master Thesis, Yıldız Technical University, İstanbul, TURKEY, 1997
- [4] Akman, S., Building damage and repair principles, TMMOB Publications, İstanbul, TURKEY, 2000
- [5] Bircan, M.M., Computer program for the examination of the vapor diffusion process in building materials and condensation calculation, Mater Thesis, Yıldız Technical University, İstanbul, TURKEY,1999.
- [6] Yüksek İ., Sıvacılar S.( 2017). Thermal Efficiency of Different Types Covered Walls TS 825 A Comparative Study on Conditions in Turkey. Politeknik Journal, 20 (2), 291-302
- [7] Özel, M, İlgin Beyazıt, N . (2018). Condensation Analysis According to Different Location of Insulation in Wall. Dicle University Journal of Engineering Faculty(DÜMF), 9 (2), 785-794
- [8] Glaser, H. (1959). Graphisches Verfahren zur Untersuchung von Diffusionsvorgangen, Kaltetechnik 11, Heft 10/59, 345-349
Details
Primary Language
English
Subjects
Mechanical Engineering
Journal Section
Research Article
Authors
Fatih Ünal
*
0000-0001-6660-9984
Türkiye
Publication Date
December 30, 2019
Submission Date
November 19, 2019
Acceptance Date
December 10, 2019
Published in Issue
Year 2019 Volume: 9 Number: 2
Cited By
Investigating the Impact of Insulation Thickness on Condensation Levels: A Case Study in Sivas, Türkiye
Black Sea Journal of Engineering and Science
https://doi.org/10.34248/bsengineering.1593337