Research Article

CONDENSATION ANALYSIS OF THE INSULATION OF WALLS ACCORDING TO DIFFERENT LOCATIONS IN MARDIN PROVINCE

Volume: 9 Number: 2 December 30, 2019
EN

CONDENSATION ANALYSIS OF THE INSULATION OF WALLS ACCORDING TO DIFFERENT LOCATIONS IN MARDIN PROVINCE

Abstract

In this study, condensation and vapor diffusion caused by different positioned insulation in the wall for Mardin province were analyzed. In the analysis, according to 2008 standard of TS 825, Glaser graphing method and graphical user interface (GUI) were used in MATLAB. Extruded polyurethane foam was used as the insulation material and normal unreinforced concrete was selected as the wall. Evaporation and condensation amounts were determined by creating 6 different wall models with the same insulation thickness of 20 cm thick and unreinforced concrete wall covered with 2 cm plaster on the inside and 3 cm thickness on the outside. The data obtained for 2 cm and 4 cm insulation thicknesses are presented in tables and the results are interpreted for Mardin province. As a result, it was seen that the worst wall structure in terms of condensation and evaporation was obtained in the middle insulated wall and later in the interior insulated wall structure. The externally insulated wall showed no condensation.

Keywords

References

  1. [1] Heperkan H.A., Bircan M.M., Sevindir M.K. (2001). Vapor diffusion and condensation in building materials, V. National Installation Engineering Congress and Exhibition, İzmir, TURKEY, 461-469
  2. [2] Umaroğulları F., Zorer Gedik, G., Mıhlayanlar, E. (2011). Condensation Control of Insulated and Uninsulated Concrete Walls in the Periodic Regime: The Case of Edirne. megaronjournal, 6(1), 13-20
  3. [3] Kavas, E., Thermal Protected Wall Sections in Eastern Anatolia Region and Condensation Control (Erzurum Case), Master Thesis, Yıldız Technical University, İstanbul, TURKEY, 1997
  4. [4] Akman, S., Building damage and repair principles, TMMOB Publications, İstanbul, TURKEY, 2000
  5. [5] Bircan, M.M., Computer program for the examination of the vapor diffusion process in building materials and condensation calculation, Mater Thesis, Yıldız Technical University, İstanbul, TURKEY,1999.
  6. [6] Yüksek İ., Sıvacılar S.( 2017). Thermal Efficiency of Different Types Covered Walls TS 825 A Comparative Study on Conditions in Turkey. Politeknik Journal, 20 (2), 291-302
  7. [7] Özel, M, İlgin Beyazıt, N . (2018). Condensation Analysis According to Different Location of Insulation in Wall. Dicle University Journal of Engineering Faculty(DÜMF), 9 (2), 785-794
  8. [8] Glaser, H. (1959). Graphisches Verfahren zur Untersuchung von Diffusionsvorgangen, Kaltetechnik 11, Heft 10/59, 345-349

Details

Primary Language

English

Subjects

Mechanical Engineering

Journal Section

Research Article

Publication Date

December 30, 2019

Submission Date

November 19, 2019

Acceptance Date

December 10, 2019

Published in Issue

Year 2019 Volume: 9 Number: 2

APA
Ünal, F. (2019). CONDENSATION ANALYSIS OF THE INSULATION OF WALLS ACCORDING TO DIFFERENT LOCATIONS IN MARDIN PROVINCE. European Journal of Technique (EJT), 9(2), 253-262. https://doi.org/10.36222/ejt.648601
AMA
1.Ünal F. CONDENSATION ANALYSIS OF THE INSULATION OF WALLS ACCORDING TO DIFFERENT LOCATIONS IN MARDIN PROVINCE. EJT. 2019;9(2):253-262. doi:10.36222/ejt.648601
Chicago
Ünal, Fatih. 2019. “CONDENSATION ANALYSIS OF THE INSULATION OF WALLS ACCORDING TO DIFFERENT LOCATIONS IN MARDIN PROVINCE”. European Journal of Technique (EJT) 9 (2): 253-62. https://doi.org/10.36222/ejt.648601.
EndNote
Ünal F (December 1, 2019) CONDENSATION ANALYSIS OF THE INSULATION OF WALLS ACCORDING TO DIFFERENT LOCATIONS IN MARDIN PROVINCE. European Journal of Technique (EJT) 9 2 253–262.
IEEE
[1]F. Ünal, “CONDENSATION ANALYSIS OF THE INSULATION OF WALLS ACCORDING TO DIFFERENT LOCATIONS IN MARDIN PROVINCE”, EJT, vol. 9, no. 2, pp. 253–262, Dec. 2019, doi: 10.36222/ejt.648601.
ISNAD
Ünal, Fatih. “CONDENSATION ANALYSIS OF THE INSULATION OF WALLS ACCORDING TO DIFFERENT LOCATIONS IN MARDIN PROVINCE”. European Journal of Technique (EJT) 9/2 (December 1, 2019): 253-262. https://doi.org/10.36222/ejt.648601.
JAMA
1.Ünal F. CONDENSATION ANALYSIS OF THE INSULATION OF WALLS ACCORDING TO DIFFERENT LOCATIONS IN MARDIN PROVINCE. EJT. 2019;9:253–262.
MLA
Ünal, Fatih. “CONDENSATION ANALYSIS OF THE INSULATION OF WALLS ACCORDING TO DIFFERENT LOCATIONS IN MARDIN PROVINCE”. European Journal of Technique (EJT), vol. 9, no. 2, Dec. 2019, pp. 253-62, doi:10.36222/ejt.648601.
Vancouver
1.Fatih Ünal. CONDENSATION ANALYSIS OF THE INSULATION OF WALLS ACCORDING TO DIFFERENT LOCATIONS IN MARDIN PROVINCE. EJT. 2019 Dec. 1;9(2):253-62. doi:10.36222/ejt.648601

Cited By

All articles published by EJT are licensed under the Creative Commons Attribution 4.0 International License. This permits anyone to copy, redistribute, remix, transmit and adapt the work provided the original work and source is appropriately cited.Creative Commons Lisansı