Araştırma Makalesi

CONDENSATION ANALYSIS OF THE INSULATION OF WALLS ACCORDING TO DIFFERENT LOCATIONS IN MARDIN PROVINCE

Cilt: 9 Sayı: 2 30 Aralık 2019
PDF İndir
EN

CONDENSATION ANALYSIS OF THE INSULATION OF WALLS ACCORDING TO DIFFERENT LOCATIONS IN MARDIN PROVINCE

Öz

In this study, condensation and vapor diffusion caused by different positioned insulation in the wall for Mardin province were analyzed. In the analysis, according to 2008 standard of TS 825, Glaser graphing method and graphical user interface (GUI) were used in MATLAB. Extruded polyurethane foam was used as the insulation material and normal unreinforced concrete was selected as the wall. Evaporation and condensation amounts were determined by creating 6 different wall models with the same insulation thickness of 20 cm thick and unreinforced concrete wall covered with 2 cm plaster on the inside and 3 cm thickness on the outside. The data obtained for 2 cm and 4 cm insulation thicknesses are presented in tables and the results are interpreted for Mardin province. As a result, it was seen that the worst wall structure in terms of condensation and evaporation was obtained in the middle insulated wall and later in the interior insulated wall structure. The externally insulated wall showed no condensation.

Anahtar Kelimeler

Kaynakça

  1. [1] Heperkan H.A., Bircan M.M., Sevindir M.K. (2001). Vapor diffusion and condensation in building materials, V. National Installation Engineering Congress and Exhibition, İzmir, TURKEY, 461-469
  2. [2] Umaroğulları F., Zorer Gedik, G., Mıhlayanlar, E. (2011). Condensation Control of Insulated and Uninsulated Concrete Walls in the Periodic Regime: The Case of Edirne. megaronjournal, 6(1), 13-20
  3. [3] Kavas, E., Thermal Protected Wall Sections in Eastern Anatolia Region and Condensation Control (Erzurum Case), Master Thesis, Yıldız Technical University, İstanbul, TURKEY, 1997
  4. [4] Akman, S., Building damage and repair principles, TMMOB Publications, İstanbul, TURKEY, 2000
  5. [5] Bircan, M.M., Computer program for the examination of the vapor diffusion process in building materials and condensation calculation, Mater Thesis, Yıldız Technical University, İstanbul, TURKEY,1999.
  6. [6] Yüksek İ., Sıvacılar S.( 2017). Thermal Efficiency of Different Types Covered Walls TS 825 A Comparative Study on Conditions in Turkey. Politeknik Journal, 20 (2), 291-302
  7. [7] Özel, M, İlgin Beyazıt, N . (2018). Condensation Analysis According to Different Location of Insulation in Wall. Dicle University Journal of Engineering Faculty(DÜMF), 9 (2), 785-794
  8. [8] Glaser, H. (1959). Graphisches Verfahren zur Untersuchung von Diffusionsvorgangen, Kaltetechnik 11, Heft 10/59, 345-349

Ayrıntılar

Birincil Dil

İngilizce

Konular

Makine Mühendisliği

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

30 Aralık 2019

Gönderilme Tarihi

19 Kasım 2019

Kabul Tarihi

10 Aralık 2019

Yayımlandığı Sayı

Yıl 2019 Cilt: 9 Sayı: 2

Kaynak Göster

APA
Ünal, F. (2019). CONDENSATION ANALYSIS OF THE INSULATION OF WALLS ACCORDING TO DIFFERENT LOCATIONS IN MARDIN PROVINCE. European Journal of Technique (EJT), 9(2), 253-262. https://doi.org/10.36222/ejt.648601
AMA
1.Ünal F. CONDENSATION ANALYSIS OF THE INSULATION OF WALLS ACCORDING TO DIFFERENT LOCATIONS IN MARDIN PROVINCE. EJT. 2019;9(2):253-262. doi:10.36222/ejt.648601
Chicago
Ünal, Fatih. 2019. “CONDENSATION ANALYSIS OF THE INSULATION OF WALLS ACCORDING TO DIFFERENT LOCATIONS IN MARDIN PROVINCE”. European Journal of Technique (EJT) 9 (2): 253-62. https://doi.org/10.36222/ejt.648601.
EndNote
Ünal F (01 Aralık 2019) CONDENSATION ANALYSIS OF THE INSULATION OF WALLS ACCORDING TO DIFFERENT LOCATIONS IN MARDIN PROVINCE. European Journal of Technique (EJT) 9 2 253–262.
IEEE
[1]F. Ünal, “CONDENSATION ANALYSIS OF THE INSULATION OF WALLS ACCORDING TO DIFFERENT LOCATIONS IN MARDIN PROVINCE”, EJT, c. 9, sy 2, ss. 253–262, Ara. 2019, doi: 10.36222/ejt.648601.
ISNAD
Ünal, Fatih. “CONDENSATION ANALYSIS OF THE INSULATION OF WALLS ACCORDING TO DIFFERENT LOCATIONS IN MARDIN PROVINCE”. European Journal of Technique (EJT) 9/2 (01 Aralık 2019): 253-262. https://doi.org/10.36222/ejt.648601.
JAMA
1.Ünal F. CONDENSATION ANALYSIS OF THE INSULATION OF WALLS ACCORDING TO DIFFERENT LOCATIONS IN MARDIN PROVINCE. EJT. 2019;9:253–262.
MLA
Ünal, Fatih. “CONDENSATION ANALYSIS OF THE INSULATION OF WALLS ACCORDING TO DIFFERENT LOCATIONS IN MARDIN PROVINCE”. European Journal of Technique (EJT), c. 9, sy 2, Aralık 2019, ss. 253-62, doi:10.36222/ejt.648601.
Vancouver
1.Fatih Ünal. CONDENSATION ANALYSIS OF THE INSULATION OF WALLS ACCORDING TO DIFFERENT LOCATIONS IN MARDIN PROVINCE. EJT. 01 Aralık 2019;9(2):253-62. doi:10.36222/ejt.648601

Cited By