BibTex RIS Kaynak Göster

-

Yıl 2013, Cilt: 3 Sayı: 6, 99 - 106, 06.03.2014

Öz

Energy efficiency continues to gain importance. Electrical machines are responsible for most of the electricity consumption. Therefore, with small increase in the efficiency of the electromagnetic machine, large energy-saving can be achieved. Accurate measurement of core losses is required to improve the efficiency of the machine during the machine design. Core loss data, usually within a limited range of frequency and flux density is provided by core producers. These data are not sufficient to estimate the core losses of electrical machines. In this study, mentioned with interest in scientific communities in recent years, SST tester is proposed and implemented for core loss measurement. With the magnetization current method the

Kaynakça

  • Zhong, J., Guo, Y., Zhu, J., Lu, H. and Jin, J. “Development of Measuring Techniques for Rotational Core Losses of Soft Magnetic Material”, Nature Sciences, 2(1):1-12, 2007.
  • Mthomben, L., Pillay, P. and Strnat, R. M. W., “New Epstein Frame for Lamination Core Loss Measurements Under High Frequencies and High Flux Densities”, IEEE Transactions on Energy Conversion, 22: 614 –620, 2007.
  • Küçük, F., “Manyetik Malzemelerde Kayıpların Ölçülmesi ve Modellenmesi”, Yüksek Lisans Tezi, İTÜ, Fen Bilimleri Enstitüsü, Elektrik ve Elektronik Mühendisliği Anabilim Dalı, İstanbul, 2002.
  • Bertotti, G., “General Properties of Power Losses in Soft Ferromagnetic Materials”, IEEE Transactions On Magnetics, 24: 621-630, 1988.

Tek Saç Testi (SST) Yöntemi ile Nüve Malzemelerin Manyetik Kayıplarının Ölçülmesi

Yıl 2013, Cilt: 3 Sayı: 6, 99 - 106, 06.03.2014

Öz

Enerji verimliliği sürekli önem kazanmaya devam etmektedir. Elektrik makinaları elektrik tüketiminin çoğundan sorumludur. Dolayısıyla elektromanyetik cihazların verimliliğinde küçük kazanımla büyük enerji tasarrufu elde edilebilir. Makine verimliliğini artırmak için makine tasarım aşamasında nüve kayıpları doğru ölçülmelidir. Nüve kayıp verileri genellikle sınırlı frekans ve akı yoğunluğu aralıkları içinde nüve üreticileri tarafından sağlanmaktadır. Bu veriler elektrikli makinelerde nüve kayıpları tahmini için yeterli değildir. Bu çalışmada bilim çevrelerinde son yıllarda ilgiyle izlenilen tek saç test cihazı(SST) tasarlanarak, nüve kaybı ölçümlerinde kullanılmıştır. Mıknatıslanma akımı yöntemi ile manyetik alan şiddeti, akım değerleri ve nüve kayıpları hesaplanmış, değişik manyetik akı ve frekanslarda(50Hz-500Hz) nüve kayıp eğrileri elde edilmiştir. Test değerlerinden eğri uydurma yöntemi ile kayıp katsayıları bulunmuştur. Elde edilen histerisiz, girdap akımı ve anormal kayıp katsayıları vasıtasıyla M4, M3 ve M5 kalite Si-Fe saç malzemelerin kayıp modelleri oluşturulmuştur. Literatürde mıknatıslanma akımı yöntemiyle çalışan SST cihazı ile kayıp katsayılarının bulunması yapılmamıştır. Çalışmada bu konuda literatüre katkı sağlamak amaçlanmıştır. 

Kaynakça

  • Zhong, J., Guo, Y., Zhu, J., Lu, H. and Jin, J. “Development of Measuring Techniques for Rotational Core Losses of Soft Magnetic Material”, Nature Sciences, 2(1):1-12, 2007.
  • Mthomben, L., Pillay, P. and Strnat, R. M. W., “New Epstein Frame for Lamination Core Loss Measurements Under High Frequencies and High Flux Densities”, IEEE Transactions on Energy Conversion, 22: 614 –620, 2007.
  • Küçük, F., “Manyetik Malzemelerde Kayıpların Ölçülmesi ve Modellenmesi”, Yüksek Lisans Tezi, İTÜ, Fen Bilimleri Enstitüsü, Elektrik ve Elektronik Mühendisliği Anabilim Dalı, İstanbul, 2002.
  • Bertotti, G., “General Properties of Power Losses in Soft Ferromagnetic Materials”, IEEE Transactions On Magnetics, 24: 621-630, 1988.
Toplam 4 adet kaynakça vardır.

Ayrıntılar

Birincil Dil Türkçe
Bölüm Özel Sayı Makaleleri (ELECO)
Yazarlar

Ahmet Demir

Yayımlanma Tarihi 6 Mart 2014
Gönderilme Tarihi 30 Mayıs 2013
Yayımlandığı Sayı Yıl 2013 Cilt: 3 Sayı: 6

Kaynak Göster

APA Demir, A. (2014). Tek Saç Testi (SST) Yöntemi ile Nüve Malzemelerin Manyetik Kayıplarının Ölçülmesi. EMO Bilimsel Dergi, 3(6), 99-106.
AMA Demir A. Tek Saç Testi (SST) Yöntemi ile Nüve Malzemelerin Manyetik Kayıplarının Ölçülmesi. EMO Bilimsel Dergi. Mart 2014;3(6):99-106.
Chicago Demir, Ahmet. “Tek Saç Testi (SST) Yöntemi Ile Nüve Malzemelerin Manyetik Kayıplarının Ölçülmesi”. EMO Bilimsel Dergi 3, sy. 6 (Mart 2014): 99-106.
EndNote Demir A (01 Mart 2014) Tek Saç Testi (SST) Yöntemi ile Nüve Malzemelerin Manyetik Kayıplarının Ölçülmesi. EMO Bilimsel Dergi 3 6 99–106.
IEEE A. Demir, “Tek Saç Testi (SST) Yöntemi ile Nüve Malzemelerin Manyetik Kayıplarının Ölçülmesi”, EMO Bilimsel Dergi, c. 3, sy. 6, ss. 99–106, 2014.
ISNAD Demir, Ahmet. “Tek Saç Testi (SST) Yöntemi Ile Nüve Malzemelerin Manyetik Kayıplarının Ölçülmesi”. EMO Bilimsel Dergi 3/6 (Mart 2014), 99-106.
JAMA Demir A. Tek Saç Testi (SST) Yöntemi ile Nüve Malzemelerin Manyetik Kayıplarının Ölçülmesi. EMO Bilimsel Dergi. 2014;3:99–106.
MLA Demir, Ahmet. “Tek Saç Testi (SST) Yöntemi Ile Nüve Malzemelerin Manyetik Kayıplarının Ölçülmesi”. EMO Bilimsel Dergi, c. 3, sy. 6, 2014, ss. 99-106.
Vancouver Demir A. Tek Saç Testi (SST) Yöntemi ile Nüve Malzemelerin Manyetik Kayıplarının Ölçülmesi. EMO Bilimsel Dergi. 2014;3(6):99-106.

EMO BİLİMSEL DERGİ
Elektrik, Elektronik, Bilgisayar, Biyomedikal, Kontrol Mühendisliği Bilimsel Hakemli Dergisi
TMMOB ELEKTRİK MÜHENDİSLERİ ODASI 
IHLAMUR SOKAK NO:10 KIZILAY/ANKARA
TEL: +90 (312) 425 32 72 (PBX) - FAKS: +90 (312) 417 38 18
bilimseldergi@emo.org.tr