Instantaneous interventions and periodic maintenance are used to
prevent motor faults. Even if the periodic maintenance extended the motor life, it
cannot prevent the occurrence of fault. Therefore, monitoring and fault detection
in motors are among important topics that scientists have focused on in recent
years.In the present study,Permanent Magnet Synchronous Motor (PMSM) is
used because of they are recently preferred in the industry especially for servo
systems due to their superiorities such as high power density, high power-speed
interval, high efficiency, high air gap-flux density and high moment-inertia
ratioThe motor dynamic vibrationsignal was monitored under stationary and
non-stationary speed and different load conditions after which the eccentricity
fault detection was carried out via Angular Domain - Order Tracking method
(AD-OT). The proposed method has successfully diagnosed the eccentricity
faults at both stationary and non-stationary conditions
Motorlar da meydana gelen arızalara anlık müdahalelerle ve periyodik
bakımlarla önlem alınmaya çalışılmaktadır. Periyodik bakımlar motorun arıza
yapma sürecini uzatsada arızaların meydana gelmesini engelleyememektedir.
Sunulan çalışmada, yüksek verim ve güç faktörü, yüksek moment-eylemsizlik
oranı ve yüksek güç-ağırlık oranıgibi üstünlüklerinden dolayı endüstriyel
otomasyon sistemlerinde oldukça yaygın kullanılan Sabit Mıknatıslı Senkron
Motorlar (SMSM) kullanılmıştır. Motor dinamik titreşim sinyalleri durağan ve
durağan olmayan hız ve farklı yük durumlarında izlenmiş, eksenden kaçıklık
arızasının tespiti Mertebe Takip Analiz Yöntemi (MTA) ile gerçekleştirilmiştir.
Önerilen yöntem durağan ve dinamik çalışma koşullarında eksenden kaçıklık
arızasının tespitinde başarılı olmuştur.