Preconcentration and electroanalysis of copper at glassy carbon electrode modified with poly(2-aminothiazole)
Abstract
Conducting poly(2-aminothiazole), PAT, was synthesized in acetonitrile with tetrabutylammonium tetrafluoroborate, TBAFB, as supporting electrolyte via constant potential electrolysis, CPE. Glassy carbon, GC, electrode was modified by immersing the electrode in a DMSO solution of PAT. Preconcentration of copper on polymer matrix was carried out at -0.7 V. The effects of preconcentration time and pH and Cu(II) concentration of the preconcentration solution on the stripping peak current of copper were studied.
Keywords
References
- Khaloo S.S., Esnafi A.A., Khayamian T., “Determination of bismuth and copper using adsorptive stripping voltammetry couple with continuous wavelet transform”, Talanta, 71: 324-332 (2007).
- Filho N.L.D., Carmo D.R,. Rosa A.H., “An electroanalytical application of 2-aminothiazole- modified silica gel after adsorption and separation of Hg(II) from heavy metals in aqueous solution”, Electrochim. Acta., 52: 965- 972 (2006).
- Yin Q.F., Ju B.Z, Zhang S.F., Wang X.B., Yang J.Z., “Preparation and characteristics of novel dialdehyde aminothiazole starch and its adsorption properties for Cu (II) ions from aqueous solution” Carbohydr. Polym., 72: 326- 333 (2008).
- Lin M., Cho M., Choe W.S., Son Y., Lee Y., “Electrochemical detection of copper ion using a modified copolythiophene electrode”, Electrochim. Acta., 54: 7012-7017 (2009).
- Zanganeh A.R., Amini M.K., “Polypyrrole- modified electrodes with induced recognition sites for potentiometric and voltammetric detection of copper(II) ion”, Sens. Actuators, B, 135: 358-365 (2008).
- Zhao H., Jiang Y., Ma Y., Wu Z., Cao Q., He Y., Li X., Yuan Z., “Poly(2-amino-4- thiazoleacetic acid)/multiwalled carbon nanotubes modified glassy carbon electrodes for the electrochemical detection of copper(II)”, Electrochim. Acta., 55: 2518-2521 (2010).
- Alcantara I.L., dos Santos Roldan P., Margionte M.A.L., Castro G.R., Padilha C.C.F., Florentino A.D., Padilha P.D., “Determination of Cu, Ni and Pb in aqueous medium by FAAS after pre- concentration on 2-aminothiazole modified silica gel”, J. Braz. Chem. Soc., 15: 366-371 (2004)
- Castro G.R., Cristante V.M., Padilha C.C.F., Jorge S.M.A., Florentino A.O., Prado A.G.S., Padilha P.M., “Determination of Cd(II), Cu(II) and Ni(II) in aqueous samples by ICP-OES after on-line preconcentration in column packed with silica modified with 2-aminothiazole”, Microchim. Acta, 160: 203-209 (2008).
Details
Primary Language
English
Subjects
Engineering
Journal Section
Conference Paper
Publication Date
January 14, 2011
Submission Date
March 11, 2010
Acceptance Date
-
Published in Issue
Year 2011 Volume: 24 Number: 1