Abstract

This paper reviews analytical methods, instrumental developments and applications for derivatization of amines and amino acids with 7-Chloro-4-nitrobenzoxadiazole (NBD-Cl) and 4-Fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F) using high performance liquid chromatography (HPLC). Discussion of the literature related to the application from 2001 to 2010 is presented.

Keywords

References

  1. Analytical column was a monolithic-ODS column (750mm×0.53mm I.D., prepare in a fused silica capillary, provided from Shiseido) elution:isocratic, eluent: for NBD-Ser was MeCN– TFA–water (5:0.05:95, v/v/v), and that for NBD-Ala was MeCN–TFA–water (15:0.05:85, v/v/v). Sumichiral OA-2500 (S) and (R) (250 4.6 mm i.d.), Elution; isocratic Eluent: 20 mm citric acid in MeOHُ analytical column for the reversed-phase separation was a Capcell pak C18 MG II (150 mm × 1.0 mm
  2. Shiseido) elution:isocratic, elutent: THF–TFA–water (25/0.05/75, v/v/v) For enantiomer separations, Chiralpak QN-AX and Chiralpak QD-AX (150 mm × 4.0 mm I.D., Chiral Technologies Europe, Illkirch, France): 10 mM citric acid in the mixed solution of MeOH–MeCN (50/50, v/v) Sample + 20 µl of mM borate buffer (pH 8.0) + 10 µl of 20 mM analytical column for the reversed-phase separation was a Mightysil RP-18 GP (100 mm × 1.0 mm I.D., Kanto Chemical, Tokyo, Japan), elution:isocratic, eluent: MeCN– THF–TFA–water (10:1:0.02:89, v/v) enantioselective column was a Sumichiral OA-2500S
  3. Chemical Analysis Service, Osaka, Japan) 5 mM citric acid in MeOH microbore-monolithic-ODS column I.D.) elution: isocratic, eluent: NBD-Ser was MeCN–TFA– water (5:0.05:95, v/v/v) a self-packed narrowbore-Pirkle type enantioselective column (Sumichiral OA-2500S, citric acid in MeOH–MeCN (50:50, v/v), analytical column a microbore- monolithic ODS column (1000 mm × 0.53 mm prepared in a fused silica capillary, provided from
  4. Barends, D.M., Blauw, J.S., Smits, M.H., and Hulshoff, A. "Determination of amikacin in serum by high-performance liquid chromatography with ultraviolet detection", J. Chromatogr. Biomed. Appl., :385-394, (1983).
  5. Spackman, D.H., Stein, W.H., and Moore, S. "Automatic recording apparatus for use in the chromatography of amino acids", Anal. Chem., 30: 1206, (1958).
  6. Soleas, G.J., Carey, M. et., and Goldberg, D.M. "Method development and cultivar-related differences of nine biogenic amines in Ontario wines", Food Chem., 64:49-58, (1999).
  7. Lanbeck-Vallen, K., Carlquist, J., and Nordgren, T. "Determination of ampicillin in biological fluids by coupled-column liquid chromatography and post- column derivatization"., J. Chromatogr. 567:121- , (1991).
  8. Edder, P., Cominoli, A., and Corvi, C. "Determination of streptomycin residues in food by solid-phase extraction and liquid chromatography with post- column derivatization and fluorometric detection", J. Chromatogr. 830:345-351, (1999).

Details

Primary Language

English

Subjects

Engineering

Journal Section

Research Article

Authors

Y Aboul-enein This is me

Abdalla Elbashır This is me

Fakhr Sulıman This is me

Publication Date

July 8, 2011

Submission Date

July 8, 2011

Acceptance Date

-

Published in Issue

Year 2011 Volume: 24 Number: 4

APA
Aboul-enein, Y., Elbashır, A., & Sulıman, F. (2011). The Application of 7-Chloro-4-Nitrobenzoxadiazole and 4-Fluoro-7-Nitro-2,1,3-Benzoxadiazole for The Analysis of Amines and Amino Acids Using High-Performance Liquid Chromatography. Gazi University Journal of Science, 24(4), 679-697. https://izlik.org/JA46UJ33YK
AMA
1.Aboul-enein Y, Elbashır A, Sulıman F. The Application of 7-Chloro-4-Nitrobenzoxadiazole and 4-Fluoro-7-Nitro-2,1,3-Benzoxadiazole for The Analysis of Amines and Amino Acids Using High-Performance Liquid Chromatography. Gazi University Journal of Science. 2011;24(4):679-697. https://izlik.org/JA46UJ33YK
Chicago
Aboul-enein, Y, Abdalla Elbashır, and Fakhr Sulıman. 2011. “The Application of 7-Chloro-4-Nitrobenzoxadiazole and 4-Fluoro-7-Nitro-2,1,3-Benzoxadiazole for The Analysis of Amines and Amino Acids Using High-Performance Liquid Chromatography”. Gazi University Journal of Science 24 (4): 679-97. https://izlik.org/JA46UJ33YK.
EndNote
Aboul-enein Y, Elbashır A, Sulıman F (December 1, 2011) The Application of 7-Chloro-4-Nitrobenzoxadiazole and 4-Fluoro-7-Nitro-2,1,3-Benzoxadiazole for The Analysis of Amines and Amino Acids Using High-Performance Liquid Chromatography. Gazi University Journal of Science 24 4 679–697.
IEEE
[1]Y. Aboul-enein, A. Elbashır, and F. Sulıman, “The Application of 7-Chloro-4-Nitrobenzoxadiazole and 4-Fluoro-7-Nitro-2,1,3-Benzoxadiazole for The Analysis of Amines and Amino Acids Using High-Performance Liquid Chromatography”, Gazi University Journal of Science, vol. 24, no. 4, pp. 679–697, Dec. 2011, [Online]. Available: https://izlik.org/JA46UJ33YK
ISNAD
Aboul-enein, Y - Elbashır, Abdalla - Sulıman, Fakhr. “The Application of 7-Chloro-4-Nitrobenzoxadiazole and 4-Fluoro-7-Nitro-2,1,3-Benzoxadiazole for The Analysis of Amines and Amino Acids Using High-Performance Liquid Chromatography”. Gazi University Journal of Science 24/4 (December 1, 2011): 679-697. https://izlik.org/JA46UJ33YK.
JAMA
1.Aboul-enein Y, Elbashır A, Sulıman F. The Application of 7-Chloro-4-Nitrobenzoxadiazole and 4-Fluoro-7-Nitro-2,1,3-Benzoxadiazole for The Analysis of Amines and Amino Acids Using High-Performance Liquid Chromatography. Gazi University Journal of Science. 2011;24:679–697.
MLA
Aboul-enein, Y, et al. “The Application of 7-Chloro-4-Nitrobenzoxadiazole and 4-Fluoro-7-Nitro-2,1,3-Benzoxadiazole for The Analysis of Amines and Amino Acids Using High-Performance Liquid Chromatography”. Gazi University Journal of Science, vol. 24, no. 4, Dec. 2011, pp. 679-97, https://izlik.org/JA46UJ33YK.
Vancouver
1.Y Aboul-enein, Abdalla Elbashır, Fakhr Sulıman. The Application of 7-Chloro-4-Nitrobenzoxadiazole and 4-Fluoro-7-Nitro-2,1,3-Benzoxadiazole for The Analysis of Amines and Amino Acids Using High-Performance Liquid Chromatography. Gazi University Journal of Science [Internet]. 2011 Dec. 1;24(4):679-97. Available from: https://izlik.org/JA46UJ33YK