Abstract

In this paper, general information about, unionized radiation, standards and measurement routines for wireless communication systems, electromagnetic fields and antenna structures are given. The safety of mobile phones has been evaluated in terms of specific absorption ratio (SAR). This SAR values have been defined discussing among international standard organizations. Electromagnetic Compatibility (EMC) measurements are made with a compact spectrum analyzer device, measures 400 MHz- 6 GHz bandwidth, and a triaxial antenna. Electromagnetic fields and power flux density values are measured, and compared with ICNIRP standard curve for safety values. These values are observed and separated for two base stations at the same point. Measured electric field and power density values are plotted by distance from base station tower, and compared with theoretical results. Safety distance is defined and calculated

Keywords:Electromagnetic compatibility; selective radiation

Keywords

References

  1. ICNIRP (International Commission on Non-Ionizing Radiation Protection), “Guidelines for limiting exposure to time varying electric, magnetic, and electromagnetic fields (up to 300 GHz)”, Health Physics, 74(4): 494–522 (1998). .
  2. Resmi Gazete, Elektronik Haberleşme Cihazlarına Güvenlik Sertifikası Düzenlenmesine İlişkin Yönetmelik, Sayısı: 27230, 16.05.(2009).
  3. Sevgi, L., “Electromagnetic Compatibility and Electromagnetic Pollution”, TMMOB Electrical Engineering Publishing Series, 320, (2000). İstanbul Department
  4. Zipse, D.W., “Electric and Magnetic Fields: Equipment and Methodology Used For Obtaining Measurements”, (1992). Conference, 285-292, mobile radio terminals”, News from
  5. Wang, O., Fujiwar, T. U., “New Approach to Safety Evaluation of Human Exposure to Stochastically- Varying Transactions on Electromagnetic Compatibility, 47(4): 971-977, (2005). Fields”, IEEE
  6. Mahadi, W., Norfizah, M.A., Wen, Q.P., “Evaluation of RF EMF Exposure Pattern on Selected Communication Tower in Malaysia”, ICSE2010 Proc., Melaka, Malaysia, 344-347, (2010).
  7. Ozgur, E., Güler, G., “Measurement of Output Radio Frequency Field Generated by Mobile Phones with Applied Sound in Different Strengths & Frequencies”, GU J Sci, 281-286, (2010).
  8. Salama, N., Kishimoto, T., Kanayama, H., “Effects of exposure to a mobile phone on testicular function and structure in adult rabbit”, International Journal of Andrology, 88-94, (2010).

Details

Primary Language

English

Subjects

-

Journal Section

-

Authors

Nilüfer As This is me

Yasin Karan This is me

Publication Date

March 31, 2013

Submission Date

July 18, 2012

Acceptance Date

-

Published in Issue

Year 2013 Volume: 26 Number: 1

APA
Şahin, M., As, N., & Karan, Y. (2013). SELECTIVE RADIATION MEASUREMENT FOR SAFETY EVALUATION ON BASE STATIONS. Gazi University Journal of Science, 26(1), 73-83. https://izlik.org/JA88EM28LA
AMA
1.Şahin M, As N, Karan Y. SELECTIVE RADIATION MEASUREMENT FOR SAFETY EVALUATION ON BASE STATIONS. Gazi University Journal of Science. 2013;26(1):73-83. https://izlik.org/JA88EM28LA
Chicago
Şahin, Mustafa, Nilüfer As, and Yasin Karan. 2013. “SELECTIVE RADIATION MEASUREMENT FOR SAFETY EVALUATION ON BASE STATIONS”. Gazi University Journal of Science 26 (1): 73-83. https://izlik.org/JA88EM28LA.
EndNote
Şahin M, As N, Karan Y (March 1, 2013) SELECTIVE RADIATION MEASUREMENT FOR SAFETY EVALUATION ON BASE STATIONS. Gazi University Journal of Science 26 1 73–83.
IEEE
[1]M. Şahin, N. As, and Y. Karan, “SELECTIVE RADIATION MEASUREMENT FOR SAFETY EVALUATION ON BASE STATIONS”, Gazi University Journal of Science, vol. 26, no. 1, pp. 73–83, Mar. 2013, [Online]. Available: https://izlik.org/JA88EM28LA
ISNAD
Şahin, Mustafa - As, Nilüfer - Karan, Yasin. “SELECTIVE RADIATION MEASUREMENT FOR SAFETY EVALUATION ON BASE STATIONS”. Gazi University Journal of Science 26/1 (March 1, 2013): 73-83. https://izlik.org/JA88EM28LA.
JAMA
1.Şahin M, As N, Karan Y. SELECTIVE RADIATION MEASUREMENT FOR SAFETY EVALUATION ON BASE STATIONS. Gazi University Journal of Science. 2013;26:73–83.
MLA
Şahin, Mustafa, et al. “SELECTIVE RADIATION MEASUREMENT FOR SAFETY EVALUATION ON BASE STATIONS”. Gazi University Journal of Science, vol. 26, no. 1, Mar. 2013, pp. 73-83, https://izlik.org/JA88EM28LA.
Vancouver
1.Mustafa Şahin, Nilüfer As, Yasin Karan. SELECTIVE RADIATION MEASUREMENT FOR SAFETY EVALUATION ON BASE STATIONS. Gazi University Journal of Science [Internet]. 2013 Mar. 1;26(1):73-8. Available from: https://izlik.org/JA88EM28LA