An Experimental Study Towards Decreasing the Energy Efficiency Index Value in Industrial Refrigerators

Volume: 9 Number: 3 September 30, 2021
TR EN

An Experimental Study Towards Decreasing the Energy Efficiency Index Value in Industrial Refrigerators

Abstract

Energy labeling is performed according to the energy efficiency index (EEI) value in industrial coolers. In order to reduce the EEI value calculated according to the amount of energy consumed and the characteristics of the cooler. Two systems were designed in this study and the energy label class of the coolers was determined according to the obtained results. In this study, two different coolers (Type 1 and Type 2) were designed, manufactured and tested. The systems are designed using R290 (propane), a new generation natural and environmentally friendly refrigerant with two inlet-outlet evaporators, double condensers and double compressors to provide a homogeneous cooling. During the experiments, temperature-pressure measurements of the cooled products and cooling system equipment were taken from certain points every minute and test data were recorded. In the experiments, the average air temperature and relative humidity values of the test chamber of the experiment with resistance glass in the Type 1 cooler were measured as 25 ℃ and 59.09%, respectively, the average air temperature and relative humidity values of the test room of the Type 2 system experiment with antifogging film were measured as 25.231 ℃ and 57.207%, respectively. In the experiments, defrosting process was carried out twice a day in the coolers. During the experiment, the highest and lowest average temperatures of the cooled products were measured as -16.18 ℃ and -19.40 ℃. Increasing product temperatures during defrosting and stopping cooling increased the power consumption in the system. As a result of the calculations, the energy efficiency index value of the Type 1 resistance model was calculated to be 60.53 and it was seen that the energy label was class “E”. In the Type 2 model in which anti-fog coating film is used, the energy efficiency index value is 49.25 and it has been observed that the energy label is class "D".

Keywords

References

  1. [1] Dixell (Asia) Co., Ltd. Case study of anti-fog film installation to prevent fogging on cabinet glass door, (2010).
  2. [2] Foster A., Hammond E., Brown T., Evans J., Maidment G., Technological options for retail refrigeration, London South Bank University, (2018).
  3. [3] Dixell (Asia) Co., Ltd. Refrigerated Case Aftermarket Anti-Fogging Film, (2009).
  4. [4] Rauss D., Mitchell S., Faramarzi R., Cool retrofit solutions in refrigerated display Cases. ACEEE Summer Study on Energy Efficient Buildings, (2008) 9-233 -- 9-244.
  5. [5] Antifoglu cam, http://www.windowfilms.co.uk/products/specialist-window-films/anti-fog-window-film/
  6. [6] Sabic Global. Price Chopper anti-fog film. Retrieved 10 17, (2014).
  7. [7] Antifoglu cam, https://fsicti.com/markets/commercial-freezer-display-cases/
  8. [8] Antifoglu cam, http://www.sunrayfilms.com/wp-content/uploads/2012/08/ANTI-FOG-PRESENTATION-PDF-Sunray.pdf

Details

Primary Language

English

Subjects

Engineering

Journal Section

Research Article

Publication Date

September 30, 2021

Submission Date

March 26, 2021

Acceptance Date

July 14, 2021

Published in Issue

Year 2021 Volume: 9 Number: 3

APA
Bahar, E. M., Erten, S., & Aktaş, M. (2021). An Experimental Study Towards Decreasing the Energy Efficiency Index Value in Industrial Refrigerators. Gazi Üniversitesi Fen Bilimleri Dergisi Part C: Tasarım Ve Teknoloji, 9(3), 432-445. https://doi.org/10.29109/gujsc.903320

Cited By

                                TRINDEX     16167        16166    21432    logo.png

      

    e-ISSN:2147-9526