Research Article

Efficiency of Hydrogel Plugging System in Non-Pleural Lung Masses

Volume: 19 Number: 3 December 27, 2022
EN TR

Efficiency of Hydrogel Plugging System in Non-Pleural Lung Masses

Abstract

Objective: The aim of this study is to evaluate the complications of non-pleural-based lung biopsies performed under Computed Tomography (CT) guidance, and the ability of the hydrogel plugging system to prevent them. Material and method: Biopsy were performed in 49 cases with non-pleural-based lung mass with a coaxial system, accompanied by CT. Hydrogel plug was immediately inserted into the tissue without removing the coaxial needle. At the end of the procedure and 2 hours later, a 5 cm area in the biopsy area was controlled by CT, and 24 hours later by chest X-ray. Pneumothoraxes detected even in a single control were accepted as positive results. The data obtained were evaluated regarding the literature based on the parameters like mass size, pleural distance, presence of emphysema, age, smoking history, passing fissure. Results: Pneumothorax was the most encountered complication observed in 13 cases (26.5%) in the study. Thorax tube was placed in 1 of these cases (2.04 %). The highest rate of pneumothorax development was detected in lesions over 4 cm (33.3%) distance. In cases where fissure was passed, pneumothorax occurred in 5 (71.4%) patients. When patients with and without pneumothorax were compared in terms of age, a statistically significant difference was found (p = 0.048). Discussion: The results show that hydrogel plug application is a successful and safe method. When pneumothorax cases were analyzed, the development of massive pneumothorax requiring tube drainage in only one case and the acceptable percentage of pneumothorax can be considered as the success of the method.

Keywords

Supporting Institution

yok

Project Number

yok

References

  1. 1. Li H, Boiselle PM, Shepard JO, Trotman-Dickenson B, McCloud TC. Diagnostic accuracy and safety of CT-guided percutaneous needle aspiration biopsy of the lung: comparison of small and large pulmonary nodules. AJR 1996; 167: 105-109.
  2. 2. Harter LP, Moss AA, Goldberg HI, Gross BH. CT-guided fine- needle aspiraions for diagnosis of benign and malignant disease. AJR 1983;140: 363-367.
  3. 3. Daly B, Templeton PA. Real-time CT fluoroscopy: evolution of an interventional tool. Radiology 1999; 211: 309-15.
  4. 4. Arslan A. Perkütan transtorasik biyopsiler. Klinik Aktüel Tıp Dergisi 2005; 1: 1-8.
  5. 5. Chojniak R, Isberner RK, Viana LM, Liao Shin Yu LS, Aita AA, Soares FA. Computed tomography guided needle biopsy: experience from 1,300 procedures. Sao Paulo Med J 2006; 124: 10-4.
  6. 6. Topal U, Berkman YM. Effect of needle tract bleeding on occurrence of pneumothorax after transthoracic needle biopsy. Eur J Radiol 2005; 53: 495-9.
  7. 7. Sinner WN. Complications of percutaneous transthoracic needle aspiration biopsy. Acta Radiol 1976; 17: 813-28.
  8. 8. Kazerooni EA, Lim FT, Mikhail A, Martinez FJ. Risk of pneumothorax in CT-guided transthoracic needle aspiration biopsy of the lung. Radiology 1996; 198: 371-5.

Details

Primary Language

English

Subjects

Clinical Sciences

Journal Section

Research Article

Publication Date

December 27, 2022

Submission Date

May 26, 2022

Acceptance Date

September 5, 2022

Published in Issue

Year 2022 Volume: 19 Number: 3

Vancouver
1.Hakan Kılıç, Cüneyt Erdogan, Güven Özkaya. Efficiency of Hydrogel Plugging System in Non-Pleural Lung Masses. Harran Üniversitesi Tıp Fakültesi Dergisi. 2022 Dec. 1;19(3):636-43. doi:10.35440/hutfd.1121831

Articles published in this journal are licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License (CC-BY-NC-SA 4.0).