Thermoeconomic Evaluation of a Basic Optimized Chemically Recuperated Gas Turbine Cycle
Abstract
In a thermoeconomic analysis, the productive structure determines the cost distribution. A chemically recuperated gas turbine cycle, optimized in order to reduce the production of irreversibilities, is analyzed using to thermoeconomic techniques. The exergy flows are disaggregated into chemical and physical exergies. The internal cost distribution is compared in three types of analyses: the Basic approach, the Functional Analysis approach and the Functional Analysis with Cost Negentropy Redistribution approach. The negentropy cost redistribution reduces the cogeneration cost, changing the exergetic costs through the cycle by about 1%.
Keywords
Details
Primary Language
English
Subjects
-
Journal Section
-
Publication Date
March 1, 2003
Submission Date
February 20, 2010
Acceptance Date
-
Published in Issue
Year 2003 Volume: 6 Number: 1
APA
Alves, L., & Nebra, S. (2003). Thermoeconomic Evaluation of a Basic Optimized Chemically Recuperated Gas Turbine Cycle. International Journal of Thermodynamics, 6(1), 13-22. https://izlik.org/JA89EM27PX
AMA
1.Alves L, Nebra S. Thermoeconomic Evaluation of a Basic Optimized Chemically Recuperated Gas Turbine Cycle. International Journal of Thermodynamics. 2003;6(1):13-22. https://izlik.org/JA89EM27PX
Chicago
Alves, Lourenço, and Silvia Nebra. 2003. “Thermoeconomic Evaluation of a Basic Optimized Chemically Recuperated Gas Turbine Cycle”. International Journal of Thermodynamics 6 (1): 13-22. https://izlik.org/JA89EM27PX.
EndNote
Alves L, Nebra S (March 1, 2003) Thermoeconomic Evaluation of a Basic Optimized Chemically Recuperated Gas Turbine Cycle. International Journal of Thermodynamics 6 1 13–22.
IEEE
[1]L. Alves and S. Nebra, “Thermoeconomic Evaluation of a Basic Optimized Chemically Recuperated Gas Turbine Cycle”, International Journal of Thermodynamics, vol. 6, no. 1, pp. 13–22, Mar. 2003, [Online]. Available: https://izlik.org/JA89EM27PX
ISNAD
Alves, Lourenço - Nebra, Silvia. “Thermoeconomic Evaluation of a Basic Optimized Chemically Recuperated Gas Turbine Cycle”. International Journal of Thermodynamics 6/1 (March 1, 2003): 13-22. https://izlik.org/JA89EM27PX.
JAMA
1.Alves L, Nebra S. Thermoeconomic Evaluation of a Basic Optimized Chemically Recuperated Gas Turbine Cycle. International Journal of Thermodynamics. 2003;6:13–22.
MLA
Alves, Lourenço, and Silvia Nebra. “Thermoeconomic Evaluation of a Basic Optimized Chemically Recuperated Gas Turbine Cycle”. International Journal of Thermodynamics, vol. 6, no. 1, Mar. 2003, pp. 13-22, https://izlik.org/JA89EM27PX.
Vancouver
1.Lourenço Alves, Silvia Nebra. Thermoeconomic Evaluation of a Basic Optimized Chemically Recuperated Gas Turbine Cycle. International Journal of Thermodynamics [Internet]. 2003 Mar. 1;6(1):13-22. Available from: https://izlik.org/JA89EM27PX