Design and Exergy Analysis of a Thermal Power Plant Using Different Types of Turkish Lignite
Abstract
The purpose of this study is to design a 240 MWel thermal power plant (TPP) to be operated with ten different types of Turkish lignite and fulfill an exergy analysis including the determination and comparison of the performance for each type of lignite. Additionally an examination of the effect of the ambient temperature on the power plant’s exergy efficiency and calculation of the CO2 emissions of each lignite type is carried out. Exergy destruction of each component is investigated by using conservation of mass, conservation of energy and exergy destruction in an open system at steady state. Sivas Kangal lignite is selected for designing. Net energy and exergy efficiencies of the plant are calculated as 37.16 and 34.84 % respectively. The analysis of the case study revealed that the boiler is the major source of exergy destruction with 299.10 MW and 83.29 % of the total exergy destruction of the overall plant. Another point is that, fuel consumption and CO2 emissions of the TPP increase with rising ambient temperature. It should be noted that, comparison between the performances and emission data of the power plants can provide useful data for the future coal-fired thermal power plants investments in Turkey.
Keywords
Details
Primary Language
English
Subjects
-
Journal Section
-
Publication Date
July 25, 2011
Submission Date
July 2, 2010
Acceptance Date
-
Published in Issue
Year 2011 Volume: 14 Number: 3
APA
Ehsana, A., & Yilmazoglu, Z. (2011). Design and Exergy Analysis of a Thermal Power Plant Using Different Types of Turkish Lignite. International Journal of Thermodynamics, 14(3), 125-133. https://izlik.org/JA55HZ24HD
AMA
1.Ehsana A, Yilmazoglu Z. Design and Exergy Analysis of a Thermal Power Plant Using Different Types of Turkish Lignite. International Journal of Thermodynamics. 2011;14(3):125-133. https://izlik.org/JA55HZ24HD
Chicago
Ehsana, Amirabedin, and Zeki Yilmazoglu. 2011. “Design and Exergy Analysis of a Thermal Power Plant Using Different Types of Turkish Lignite”. International Journal of Thermodynamics 14 (3): 125-33. https://izlik.org/JA55HZ24HD.
EndNote
Ehsana A, Yilmazoglu Z (July 1, 2011) Design and Exergy Analysis of a Thermal Power Plant Using Different Types of Turkish Lignite. International Journal of Thermodynamics 14 3 125–133.
IEEE
[1]A. Ehsana and Z. Yilmazoglu, “Design and Exergy Analysis of a Thermal Power Plant Using Different Types of Turkish Lignite”, International Journal of Thermodynamics, vol. 14, no. 3, pp. 125–133, July 2011, [Online]. Available: https://izlik.org/JA55HZ24HD
ISNAD
Ehsana, Amirabedin - Yilmazoglu, Zeki. “Design and Exergy Analysis of a Thermal Power Plant Using Different Types of Turkish Lignite”. International Journal of Thermodynamics 14/3 (July 1, 2011): 125-133. https://izlik.org/JA55HZ24HD.
JAMA
1.Ehsana A, Yilmazoglu Z. Design and Exergy Analysis of a Thermal Power Plant Using Different Types of Turkish Lignite. International Journal of Thermodynamics. 2011;14:125–133.
MLA
Ehsana, Amirabedin, and Zeki Yilmazoglu. “Design and Exergy Analysis of a Thermal Power Plant Using Different Types of Turkish Lignite”. International Journal of Thermodynamics, vol. 14, no. 3, July 2011, pp. 125-33, https://izlik.org/JA55HZ24HD.
Vancouver
1.Amirabedin Ehsana, Zeki Yilmazoglu. Design and Exergy Analysis of a Thermal Power Plant Using Different Types of Turkish Lignite. International Journal of Thermodynamics [Internet]. 2011 Jul. 1;14(3):125-33. Available from: https://izlik.org/JA55HZ24HD