Abstract

The influence of particular regenerative feed-water heaters on the operational costs of a steam power plant and HP plant has been determined by means of the incremental energy efficiency expressing the ratio of the increase of electricity production to the increase of the consumption of chemical energy of fuel, assuming a constant flow rate of steam at the outlet of the turbine (power plant) or a given production rate of useful heat (HP plant). Exemplary calculations are included.

Year 2005, Volume: 8 Issue: 3, 137 - 141, 01.09.2005

Abstract

There are 0 citations in total.

Details

Primary Language English
Journal Section Regular Original Research Article
Authors

Jan Szargut

Publication Date September 1, 2005
Published in Issue Year 2005 Volume: 8 Issue: 3

Cite

APA Szargut, J. (2005). Influence of Regenerative Feed Water Heaters on the Operational Costs of Steam Power Plants and HP Plants. International Journal of Thermodynamics, 8(3), 137-141.
AMA Szargut J. Influence of Regenerative Feed Water Heaters on the Operational Costs of Steam Power Plants and HP Plants. International Journal of Thermodynamics. September 2005;8(3):137-141.
Chicago Szargut, Jan. “Influence of Regenerative Feed Water Heaters on the Operational Costs of Steam Power Plants and HP Plants”. International Journal of Thermodynamics 8, no. 3 (September 2005): 137-41.
EndNote Szargut J (September 1, 2005) Influence of Regenerative Feed Water Heaters on the Operational Costs of Steam Power Plants and HP Plants. International Journal of Thermodynamics 8 3 137–141.
IEEE J. Szargut, “Influence of Regenerative Feed Water Heaters on the Operational Costs of Steam Power Plants and HP Plants”, International Journal of Thermodynamics, vol. 8, no. 3, pp. 137–141, 2005.
ISNAD Szargut, Jan. “Influence of Regenerative Feed Water Heaters on the Operational Costs of Steam Power Plants and HP Plants”. International Journal of Thermodynamics 8/3 (September 2005), 137-141.
JAMA Szargut J. Influence of Regenerative Feed Water Heaters on the Operational Costs of Steam Power Plants and HP Plants. International Journal of Thermodynamics. 2005;8:137–141.
MLA Szargut, Jan. “Influence of Regenerative Feed Water Heaters on the Operational Costs of Steam Power Plants and HP Plants”. International Journal of Thermodynamics, vol. 8, no. 3, 2005, pp. 137-41.
Vancouver Szargut J. Influence of Regenerative Feed Water Heaters on the Operational Costs of Steam Power Plants and HP Plants. International Journal of Thermodynamics. 2005;8(3):137-41.