Research Article

Investigation of Optimal Solution Type and Volume for Inflation of Foley Catheter Balloon in Indwelling Urethral Catheterization

Volume: 7 Number: 2 May 31, 2022
TR EN

Investigation of Optimal Solution Type and Volume for Inflation of Foley Catheter Balloon in Indwelling Urethral Catheterization

Abstract

Objective: In this study investigates the effect of the type and volume of solution used in inflation of the foley catheter balloon on the development of urine leakage around the catheter during indwelling urethral catheterization. Material and Method: This randomized controlled experimental study was conducted with 128 patients hospitalized in the intensive care unit and carried out between 2015 and 2019. In each study group, different types and volumes of the solution including 10 mL 0.9% sodium chloride, 15 mL 0.9% sodium chloride, 10 mL sterile distilled water, and 15 mL sterile distilled water were used to inflate the foley balloon. Results: In the study, 7% of the patients who underwent indwelling urinary catheterization had urine leakage around the catheter. Urine leakage occurred on a mean of 11.33±8.22 days of catheterization. The urine leakage rate was calculated as 7.22/1000 catheterization days. Urine leakage rates of 10 mL 0.9% sodium chloride, 15 mL 0.9% sodium chloride, 10 mL sterile distilled water, and 15 mL sterile distilled water on the day of 1000 catheterization were 7.72, 5.60, 13.25, and 3.01 catheterization days, respectively. The most frequent urine leakage was in catheterizations using 10 mL sterile distilled water. Urine leakage was lower in catheterizations using 15 mL sterile distilled water compared to other groups. Conclusion: Using 15 mL of sterile distilled water to inflate the balloon can minimize urine leakage to ensure that the catheterization continues safely.

Keywords

References

  1. Wu AK, Blaschko SD, Garcia M, McAninch JW, Aaronson DS. Safer urethral catheters: How study of catheter balloon pressure and force can guide design. BJU Int. 2012;109(7):1110–4.
  2. Huang JG, Ooi J, Lawrentschuk N, Chan STF, Travis D, Wong LM. Urinary catheter balloons should only be filled with water: Testing the myth. BJU Int. 2009;104(11):1693–5.
  3. Sharpe SJ, Mann FA, Wiedmeyer CE, Wagner-Mann C, Thomovsky EJ. Optimal filling solution for silicone Foley catheter balloons. Can Vet J. 2011;52(10):1111–4.
  4. Hui J, Ng CF, Chan LW, Chan PSF. Can normal saline be used to fill the balloon of a Foley catheter? The experience of a prospective randomized study in China. Int J Urol. 2004;11(10):845–7.
  5. Daneshmand S, Youssefzadeh D, Skinner EC. Review of techniques to remove a Foley catheter when the balloon does not deflate. Urology. 2002;59(1):127–9.
  6. Gonzalgo ML, Walsh PC. Balloon cuffing and management of the entrapped Foley catheter. Urology. 2003;61(4):825–7.
  7. Cohen, J. Statistical Power Analysis for the Behavioral Sciences. Hillsdale (NJ): Lawrence Erlbaum Associates (1988): 18-74.
  8. Roe BH, Brocklehurst JC. Study of patients with indwelling catheters. J Adv Nurs. 1987;12(6):713–8.

Details

Primary Language

English

Subjects

Health Care Administration

Journal Section

Research Article

Publication Date

May 31, 2022

Submission Date

June 26, 2021

Acceptance Date

April 19, 2022

Published in Issue

Year 2022 Volume: 7 Number: 2

APA
Akbıyık, A., Özel, E., Çetin, P., & Khorshid, L. (2022). Investigation of Optimal Solution Type and Volume for Inflation of Foley Catheter Balloon in Indwelling Urethral Catheterization. İzmir Katip Çelebi Üniversitesi Sağlık Bilimleri Fakültesi Dergisi, 7(2), 289-293. https://izlik.org/JA35KZ49UJ
AMA
1.Akbıyık A, Özel E, Çetin P, Khorshid L. Investigation of Optimal Solution Type and Volume for Inflation of Foley Catheter Balloon in Indwelling Urethral Catheterization. İKÇÜSBFD. 2022;7(2):289-293. https://izlik.org/JA35KZ49UJ
Chicago
Akbıyık, Ayşe, Ebru Özel, Perihan Çetin, and Leyla Khorshid. 2022. “Investigation of Optimal Solution Type and Volume for Inflation of Foley Catheter Balloon in Indwelling Urethral Catheterization”. İzmir Katip Çelebi Üniversitesi Sağlık Bilimleri Fakültesi Dergisi 7 (2): 289-93. https://izlik.org/JA35KZ49UJ.
EndNote
Akbıyık A, Özel E, Çetin P, Khorshid L (May 1, 2022) Investigation of Optimal Solution Type and Volume for Inflation of Foley Catheter Balloon in Indwelling Urethral Catheterization. İzmir Katip Çelebi Üniversitesi Sağlık Bilimleri Fakültesi Dergisi 7 2 289–293.
IEEE
[1]A. Akbıyık, E. Özel, P. Çetin, and L. Khorshid, “Investigation of Optimal Solution Type and Volume for Inflation of Foley Catheter Balloon in Indwelling Urethral Catheterization”, İKÇÜSBFD, vol. 7, no. 2, pp. 289–293, May 2022, [Online]. Available: https://izlik.org/JA35KZ49UJ
ISNAD
Akbıyık, Ayşe - Özel, Ebru - Çetin, Perihan - Khorshid, Leyla. “Investigation of Optimal Solution Type and Volume for Inflation of Foley Catheter Balloon in Indwelling Urethral Catheterization”. İzmir Katip Çelebi Üniversitesi Sağlık Bilimleri Fakültesi Dergisi 7/2 (May 1, 2022): 289-293. https://izlik.org/JA35KZ49UJ.
JAMA
1.Akbıyık A, Özel E, Çetin P, Khorshid L. Investigation of Optimal Solution Type and Volume for Inflation of Foley Catheter Balloon in Indwelling Urethral Catheterization. İKÇÜSBFD. 2022;7:289–293.
MLA
Akbıyık, Ayşe, et al. “Investigation of Optimal Solution Type and Volume for Inflation of Foley Catheter Balloon in Indwelling Urethral Catheterization”. İzmir Katip Çelebi Üniversitesi Sağlık Bilimleri Fakültesi Dergisi, vol. 7, no. 2, May 2022, pp. 289-93, https://izlik.org/JA35KZ49UJ.
Vancouver
1.Ayşe Akbıyık, Ebru Özel, Perihan Çetin, Leyla Khorshid. Investigation of Optimal Solution Type and Volume for Inflation of Foley Catheter Balloon in Indwelling Urethral Catheterization. İKÇÜSBFD [Internet]. 2022 May 1;7(2):289-93. Available from: https://izlik.org/JA35KZ49UJ



Licensed under a Creative Commons Attribution 4.0 International License.