In this study, the use of R1234ze(E), R152a and R444a as alternative to R134a in a mobile air conditioning
(MAC) system are tested. The performance characteristics of R134a, R444a, R1234ze(E) and R152a were
experimentally examined in a MAC system by changing the air temperatures. Besides, the influence of compressor
volume when the system operates with R1234ze(E) was investigated. The results show that the heating performance of
R152a are higher than those obtained from R134a, R444a, R1234ze(E). Additionally, R1234ze(E) has lowest heating
capacities among the low GWP refrigerants investigated. The heating performance of R1234ze(E) increased along
with increasing the total compressor volume. Finally, R444a, R152a and R1234ze(E) can be used as alternative to
R134a in MAC systems when the necessary improvements are made.
Bu çalışmada, R134a'ya alternatif olarak R1234ze(E), R152a ve R444a soğutucu akışkanlarının bir mobil
iklimlendirme sisteminde kullanımı test edilmiştir. Hava sıcaklıkları değiştirilerek R134a, R444a, R1234ze(E) ve
R152a'nın performans özellikleri deneysel olarak incelenmiştir. Ayrıca, sistem R1234ze(E) ile çalışırken kompresör
hacminin etkisi araştırılmıştır. Sonuçlar, R152a’dan elde edilen ısıtma performansı değerlerinin R134a, R444a ve
R1234ze(E)'den daha yüksek olduğunu göstermektedir. Ayrıca, R1234ze(E) en düşük ısıtma performansı değerlerine
sahiptir. R1234ze(E)’nin ısıtma kapasitesi, toplam kompresör hacminin artmasıyla birlikte artmıştır. Son olarak,
R444a, R152a ve R1234ze(E), gerekli iyileştirmeler yapıldığında mobil iklimlendirme sistemlerinde R134a'ya
alternatif olarak kullanılabilir.