EN
Image Reconstruction for Head Laser Tomography System
Abstract
New hardware and image reconstruction algorithm for diffuse optical imaging (DOI) is presented in this work. Image reconstruction approach for new biomedical imaging device is presented. General-purpose laser scanner was used as a data acquisition unit for back-reflected laser light. It has one photodetector. One photodiode used with surface scanning process might be considered as multi detector system. Photodiode, inside the laser scanner collects escaping photons from tissue surface, can be evaluated as many photodetectors. Photodiode collects back reflected escaping photons from heterogeneous tissue or tissue like phantom media’s each surface line pixel. Basically, solenoid mirror relay vibrates the laser pointer at surface, in very short time interval. Back reflected laser light is collected by one photodiode. In this work, noncontact laser scanning tomography device concept and simulative image reconstruction procedure is presented. Image reconstruction was done base on the isobestic blood dependent laser wavelength, which is 850 nm.
Keywords
References
- References
- Wang LV, Wu H. Biomedical Optics: Principles and Imaging. New Jersey: Wiley, 2007; 362.
- González-Rodríguez P, Kim AD. Comparison of light scattering models for diffuse optical tomography. Opt Express. 2009;17(11):8756-8774.
- Ansari MA, et al. Diffuse Optical Tomography: Image Reconstruction and Verification. J Lasers Med Sci. 2014;5(1):13-18.
- Siegel A, et al. Design and evaluation of a continuous-wave diffuse optical tomography system. Opt Express. 1999;4(8):287-298.
- Yodh A, Chance B. Spectroscopy and imaging with diffusing light. Phys Today. 1995;48:34-40.
- Intes X, Chance B. Non-PET functional imaging techniques. Radiol Clin North Am. 2005;43(1):221-234.
- Hielscher AH, et al. Near-infrared diffuse optical tomography. Dis Markers. 2002;18(5-6):313-337.
Details
Primary Language
Turkish
Subjects
-
Journal Section
-
Authors
Publication Date
November 13, 2016
Submission Date
March 7, 2016
Acceptance Date
-
Published in Issue
Year 2016 Volume: 2 Number: 4
APA
Kazancı, H. Ö. (2016). Image Reconstruction for Head Laser Tomography System. İbni Sina Tıp Bilimleri Dergisi, 2(4), 51-55. https://izlik.org/JA75LU58FF
AMA
1.Kazancı HÖ. Image Reconstruction for Head Laser Tomography System. İbni Sina Tıp Bilimleri Dergisi. 2016;2(4):51-55. https://izlik.org/JA75LU58FF
Chicago
Kazancı, Hüseyin Özgür. 2016. “Image Reconstruction for Head Laser Tomography System”. İbni Sina Tıp Bilimleri Dergisi 2 (4): 51-55. https://izlik.org/JA75LU58FF.
EndNote
Kazancı HÖ (November 1, 2016) Image Reconstruction for Head Laser Tomography System. İbni Sina Tıp Bilimleri Dergisi 2 4 51–55.
IEEE
[1]H. Ö. Kazancı, “Image Reconstruction for Head Laser Tomography System”, İbni Sina Tıp Bilimleri Dergisi, vol. 2, no. 4, pp. 51–55, Nov. 2016, [Online]. Available: https://izlik.org/JA75LU58FF
ISNAD
Kazancı, Hüseyin Özgür. “Image Reconstruction for Head Laser Tomography System”. İbni Sina Tıp Bilimleri Dergisi 2/4 (November 1, 2016): 51-55. https://izlik.org/JA75LU58FF.
JAMA
1.Kazancı HÖ. Image Reconstruction for Head Laser Tomography System. İbni Sina Tıp Bilimleri Dergisi. 2016;2:51–55.
MLA
Kazancı, Hüseyin Özgür. “Image Reconstruction for Head Laser Tomography System”. İbni Sina Tıp Bilimleri Dergisi, vol. 2, no. 4, Nov. 2016, pp. 51-55, https://izlik.org/JA75LU58FF.
Vancouver
1.Hüseyin Özgür Kazancı. Image Reconstruction for Head Laser Tomography System. İbni Sina Tıp Bilimleri Dergisi [Internet]. 2016 Nov. 1;2(4):51-5. Available from: https://izlik.org/JA75LU58FF