EN
Image Reconstruction for Head Laser Tomography System
Öz
New hardware and image reconstruction algorithm for diffuse optical imaging (DOI) is presented in this work. Image reconstruction approach for new biomedical imaging device is presented. General-purpose laser scanner was used as a data acquisition unit for back-reflected laser light. It has one photodetector. One photodiode used with surface scanning process might be considered as multi detector system. Photodiode, inside the laser scanner collects escaping photons from tissue surface, can be evaluated as many photodetectors. Photodiode collects back reflected escaping photons from heterogeneous tissue or tissue like phantom media’s each surface line pixel. Basically, solenoid mirror relay vibrates the laser pointer at surface, in very short time interval. Back reflected laser light is collected by one photodiode. In this work, noncontact laser scanning tomography device concept and simulative image reconstruction procedure is presented. Image reconstruction was done base on the isobestic blood dependent laser wavelength, which is 850 nm.
Anahtar Kelimeler
Kaynakça
- References
- Wang LV, Wu H. Biomedical Optics: Principles and Imaging. New Jersey: Wiley, 2007; 362.
- González-Rodríguez P, Kim AD. Comparison of light scattering models for diffuse optical tomography. Opt Express. 2009;17(11):8756-8774.
- Ansari MA, et al. Diffuse Optical Tomography: Image Reconstruction and Verification. J Lasers Med Sci. 2014;5(1):13-18.
- Siegel A, et al. Design and evaluation of a continuous-wave diffuse optical tomography system. Opt Express. 1999;4(8):287-298.
- Yodh A, Chance B. Spectroscopy and imaging with diffusing light. Phys Today. 1995;48:34-40.
- Intes X, Chance B. Non-PET functional imaging techniques. Radiol Clin North Am. 2005;43(1):221-234.
- Hielscher AH, et al. Near-infrared diffuse optical tomography. Dis Markers. 2002;18(5-6):313-337.
Ayrıntılar
Birincil Dil
Türkçe
Konular
-
Bölüm
-
Yazarlar
Yayımlanma Tarihi
13 Kasım 2016
Gönderilme Tarihi
7 Mart 2016
Kabul Tarihi
-
Yayımlandığı Sayı
Yıl 2016 Cilt: 2 Sayı: 4
APA
Kazancı, H. Ö. (2016). Image Reconstruction for Head Laser Tomography System. İbni Sina Tıp Bilimleri Dergisi, 2(4), 51-55. https://izlik.org/JA75LU58FF
AMA
1.Kazancı HÖ. Image Reconstruction for Head Laser Tomography System. İbni Sina Tıp Bilimleri Dergisi. 2016;2(4):51-55. https://izlik.org/JA75LU58FF
Chicago
Kazancı, Hüseyin Özgür. 2016. “Image Reconstruction for Head Laser Tomography System”. İbni Sina Tıp Bilimleri Dergisi 2 (4): 51-55. https://izlik.org/JA75LU58FF.
EndNote
Kazancı HÖ (01 Kasım 2016) Image Reconstruction for Head Laser Tomography System. İbni Sina Tıp Bilimleri Dergisi 2 4 51–55.
IEEE
[1]H. Ö. Kazancı, “Image Reconstruction for Head Laser Tomography System”, İbni Sina Tıp Bilimleri Dergisi, c. 2, sy 4, ss. 51–55, Kas. 2016, [çevrimiçi]. Erişim adresi: https://izlik.org/JA75LU58FF
ISNAD
Kazancı, Hüseyin Özgür. “Image Reconstruction for Head Laser Tomography System”. İbni Sina Tıp Bilimleri Dergisi 2/4 (01 Kasım 2016): 51-55. https://izlik.org/JA75LU58FF.
JAMA
1.Kazancı HÖ. Image Reconstruction for Head Laser Tomography System. İbni Sina Tıp Bilimleri Dergisi. 2016;2:51–55.
MLA
Kazancı, Hüseyin Özgür. “Image Reconstruction for Head Laser Tomography System”. İbni Sina Tıp Bilimleri Dergisi, c. 2, sy 4, Kasım 2016, ss. 51-55, https://izlik.org/JA75LU58FF.
Vancouver
1.Hüseyin Özgür Kazancı. Image Reconstruction for Head Laser Tomography System. İbni Sina Tıp Bilimleri Dergisi [Internet]. 01 Kasım 2016;2(4):51-5. Erişim adresi: https://izlik.org/JA75LU58FF