Research Article

Disposable Voltammetric Determination of Celestine Blue at a Pencil Graphite Electrode

Volume: 10 Number: 1 March 15, 2024
EN

Disposable Voltammetric Determination of Celestine Blue at a Pencil Graphite Electrode

Abstract

The proposed study describes a novel and disposable voltammetric sensor that designed for the sensitive determination of celestine blue (CelsB) using a pencil graphite electrode (PGE). The electrochemical characterization study of the designed sensor was performed by recording the cyclic voltammograms (CVs) and electrochemical impedance (EI) curves in 5.0 mM of Fe(CN)63-/4- including 0.10 M of KCl, and compared with the other carbon-based electrodes such as carbon paste (CPE) and glassy carbon (GCE) electrodes. The electrochemical behaviour of CelsB was examined at different carbon-based electrodes including PGE, CPE, and GCE by the cyclic voltammetric (CV) method. The recorded CVs showed that the remarkable response obtained at PGE toward oxidation of CelsB. Moreover, the PGE shows a wide linear range (4.0 − 150 μM) and detects the CelsB with a notable limit of detection (1.21 μM). In addition, the results from the interference studies proved that the PGE enables selective voltammetric determination of CelsB in presence of various species. A feasibility study for CelsB sensor was also tested on tap water and cherry apple juice samples and the recovery values obtained between 96.2 − 103 % with high precision and accuracy indicated that the PGE shows an acceptable and good applicability to real samples.

Keywords

References

  1. V. Aruna Janani, D. Gokul, N. Dhivya, A. Nesarani, K. Mukilan, A. Suresh Kumar, M. Vignesh Kumar, Optimization studies on methyl orange (MO) dye adsorption using activated carbon nanoadsorbent of ocimum basilicum linn leaves, Journal of Nanomaterials 2023 (2023) Article ID 7969512 14 pages.
  2. M. Roushani, Z. Saedi, Z. Mirzaei Karazan, A. Azadbakhat, Electrochemical detection of celestine blue based on screen printed carbon electrode modified with molecular imprinted polymer and NiO nanoparticles, Analytical and Bioanalytical Chemistry Research 8 (4) (2021) 493–504.
  3. K. G. Akpomie, J. Conradie, Biosorption and regeneration potentials of magnetite nanoparticle loaded solanum tuberosum peel for celestine blue dye, International Journal of Phytoremediation 23 (4) (2021) 347–361.
  4. P. S. Ganesh, G. Shimoga, S. H. Lee, S. Y. Kim, E. E. Ebenso, Interference free simultaneous detection of dihydroxy benzene isomers at cost‐effective and reliable celestine blue modified glassy carbon electrode, ChemistrySelect 6 (9) (2021) 2379–2386.
  5. Y. Chen, Y. Zhong, J. X. Ye, Y. Lei, A. L. Liu, Facile label-free electrochemical dna biosensor for detection of osteosarcoma-related survivin gene, Biosensors 12 (9) (2022) 747 11 pages.
  6. A. Valipour, M. Roushani, TiO2 nanoparticles doped with celestine blue as a label in a sandwich immunoassay for the hepatitis C virus core antigen using a screen printed electrode, Microchimica Acta 184 (2017) 2015–2022.
  7. A. Noorbakhsh, M. Khakpoor, M. Rafieniya, E. Sharifi, M. Mehrasa, Highly sensitive electrochemical hydrogen peroxide sensor based on iron oxide‐reduced graphene oxide‐chitosan modified with DNA‐celestine blue, Electroanalysis 29 (4) (2017) 1113–1123.
  8. E. Hamidi-Asl, J. B. Raoof, A. S. Meibodi, Z. H. Bazgir, Celestine blue as a new indicator in electrochemical DNA biosensors, Science China Chemistry 59 (1) (2016) 128–134.

Details

Primary Language

English

Subjects

Electrochemistry

Journal Section

Research Article

Early Pub Date

March 15, 2024

Publication Date

March 15, 2024

Submission Date

October 1, 2023

Acceptance Date

November 21, 2023

Published in Issue

Year 2024 Volume: 10 Number: 1

APA
Güneş, M. (2024). Disposable Voltammetric Determination of Celestine Blue at a Pencil Graphite Electrode. Journal of Advanced Research in Natural and Applied Sciences, 10(1), 106-115. https://doi.org/10.28979/jarnas.1369727
AMA
1.Güneş M. Disposable Voltammetric Determination of Celestine Blue at a Pencil Graphite Electrode. JARNAS. 2024;10(1):106-115. doi:10.28979/jarnas.1369727
Chicago
Güneş, Mehmet. 2024. “Disposable Voltammetric Determination of Celestine Blue at a Pencil Graphite Electrode”. Journal of Advanced Research in Natural and Applied Sciences 10 (1): 106-15. https://doi.org/10.28979/jarnas.1369727.
EndNote
Güneş M (March 1, 2024) Disposable Voltammetric Determination of Celestine Blue at a Pencil Graphite Electrode. Journal of Advanced Research in Natural and Applied Sciences 10 1 106–115.
IEEE
[1]M. Güneş, “Disposable Voltammetric Determination of Celestine Blue at a Pencil Graphite Electrode”, JARNAS, vol. 10, no. 1, pp. 106–115, Mar. 2024, doi: 10.28979/jarnas.1369727.
ISNAD
Güneş, Mehmet. “Disposable Voltammetric Determination of Celestine Blue at a Pencil Graphite Electrode”. Journal of Advanced Research in Natural and Applied Sciences 10/1 (March 1, 2024): 106-115. https://doi.org/10.28979/jarnas.1369727.
JAMA
1.Güneş M. Disposable Voltammetric Determination of Celestine Blue at a Pencil Graphite Electrode. JARNAS. 2024;10:106–115.
MLA
Güneş, Mehmet. “Disposable Voltammetric Determination of Celestine Blue at a Pencil Graphite Electrode”. Journal of Advanced Research in Natural and Applied Sciences, vol. 10, no. 1, Mar. 2024, pp. 106-15, doi:10.28979/jarnas.1369727.
Vancouver
1.Mehmet Güneş. Disposable Voltammetric Determination of Celestine Blue at a Pencil Graphite Electrode. JARNAS. 2024 Mar. 1;10(1):106-15. doi:10.28979/jarnas.1369727

 

 

 

TR Dizin 20466
 

 

SAO/NASA Astrophysics Data System (ADS)    34270

                                                   American Chemical Society-Chemical Abstracts Service CAS    34922 

 

DOAJ 32869

EBSCO 32870

Scilit 30371                        

SOBİAD 20460

 

29804 JARNAS is licensed under a Creative Commons Attribution-NonCommercial 4.0 International Licence (CC BY-NC).