EN
TR
THE EFFECTS OF DIFFERENT ATTACHMENT SYSTEMS ON STRESS IN 2-IMPLANTRETAINED OVERDENTURES
Abstract
Osseointegrated implants have been used to improve denture support, stability and retention. Currently, the placement of 2 implants and the fabrication of an implantretained overdenture is considered by some to be the standard of care. The influence of various types of attachments on stress distribution of 2-implant-retained mandibular overdenture designs has not been sufficiently assessed. The purpose of this study was to compare the load transfer characteristics of 5 attachment systems for 2-implant-retained mandibular overdenture designs. One photoelastic model was fabricated having 2 screw-type implants (3.75 X 13 mm) embedded in the interforaminal region and implants were parallel to each other and vertically oriented. Five retention mechanisms were studied on model; a bar with yellowcolored clips, a milled galvanoformed bar, a bar with two clear distal locator attachments, a bar with two distal ceka attachments, clear locator attachments. For measurements of stress a vertical load 135 N was applied unilaterally to the central fossa of the right first molar. The resultant stresses that developed in the supporting structure were monitored photoelastically and recorded photographically. A bar with two clear distal locator attachments and,clear locator attachments showed higher stress than other attachments
Keywords
References
- Al-Ghafli, S.A., Michalakis, K.X., Hirayama, H., Kang, K., 2009. The in vitro effect of different implant angulations and cyclic dislodgement on the retentive properties of an overdenture attachment system. J Prosthet Dent, 102, 140-147.
- Alsiyabi, A.S., Feiton, D.A., Cooper, L.F., 2005. The role of abutment-attachment selection in resolving inadequate interarch distance: A clinical report. J Prosthodont, 14, 184-190.
- Bergendal, T., Engquist, B., 1998. Implant-supported overdentures: A longitudinal prospective study. Int J Oral Maxillofac Implants, 13, 253-262.
- Bueno-Samper, A., Hernandez-Aliaga, M., Calvo- Guirado, J.L., 2010. The implant-supported milled bar overdenture: A literature review. Med Oral Patol Oral Cir Bucal, 15, 375-378.
- Burns, D.R., Unger, J.W., Elswick, R.K., Beck, D.A., 1995. Prospective clinical evaluation of mandibular implant overdentures: Part I. Retention, stability and tissue response. J Prosthet Dent, 73, 364-9.
- Celik, G,, Uludag, B., 2014. Effect of the number of
- supporting implants on mandibular photoelastic
- models with different implant-retained overdenture
Details
Primary Language
English
Subjects
Engineering
Journal Section
Report
Publication Date
December 30, 2014
Submission Date
January 1, 2015
Acceptance Date
-
Published in Issue
Year 2014 Volume: 2 Number: 3
APA
Polat, S., & Uludag, B. (2014). THE EFFECTS OF DIFFERENT ATTACHMENT SYSTEMS ON STRESS IN 2-IMPLANTRETAINED OVERDENTURES. Mühendislik Bilimleri Ve Tasarım Dergisi, 2(3), 267-271. https://izlik.org/JA83AP29LH
AMA
1.Polat S, Uludag B. THE EFFECTS OF DIFFERENT ATTACHMENT SYSTEMS ON STRESS IN 2-IMPLANTRETAINED OVERDENTURES. JESD. 2014;2(3):267-271. https://izlik.org/JA83AP29LH
Chicago
Polat, Serdar, and Bulent Uludag. 2014. “THE EFFECTS OF DIFFERENT ATTACHMENT SYSTEMS ON STRESS IN 2-IMPLANTRETAINED OVERDENTURES”. Mühendislik Bilimleri Ve Tasarım Dergisi 2 (3): 267-71. https://izlik.org/JA83AP29LH.
EndNote
Polat S, Uludag B (December 1, 2014) THE EFFECTS OF DIFFERENT ATTACHMENT SYSTEMS ON STRESS IN 2-IMPLANTRETAINED OVERDENTURES. Mühendislik Bilimleri ve Tasarım Dergisi 2 3 267–271.
IEEE
[1]S. Polat and B. Uludag, “THE EFFECTS OF DIFFERENT ATTACHMENT SYSTEMS ON STRESS IN 2-IMPLANTRETAINED OVERDENTURES”, JESD, vol. 2, no. 3, pp. 267–271, Dec. 2014, [Online]. Available: https://izlik.org/JA83AP29LH
ISNAD
Polat, Serdar - Uludag, Bulent. “THE EFFECTS OF DIFFERENT ATTACHMENT SYSTEMS ON STRESS IN 2-IMPLANTRETAINED OVERDENTURES”. Mühendislik Bilimleri ve Tasarım Dergisi 2/3 (December 1, 2014): 267-271. https://izlik.org/JA83AP29LH.
JAMA
1.Polat S, Uludag B. THE EFFECTS OF DIFFERENT ATTACHMENT SYSTEMS ON STRESS IN 2-IMPLANTRETAINED OVERDENTURES. JESD. 2014;2:267–271.
MLA
Polat, Serdar, and Bulent Uludag. “THE EFFECTS OF DIFFERENT ATTACHMENT SYSTEMS ON STRESS IN 2-IMPLANTRETAINED OVERDENTURES”. Mühendislik Bilimleri Ve Tasarım Dergisi, vol. 2, no. 3, Dec. 2014, pp. 267-71, https://izlik.org/JA83AP29LH.
Vancouver
1.Serdar Polat, Bulent Uludag. THE EFFECTS OF DIFFERENT ATTACHMENT SYSTEMS ON STRESS IN 2-IMPLANTRETAINED OVERDENTURES. JESD [Internet]. 2014 Dec. 1;2(3):267-71. Available from: https://izlik.org/JA83AP29LH