THE EFFECTS OF A COLUMN DAMAGE TO STRUCTURAL BEHAVIOR OF AN EXAMPLE LOW-STRENGTH CONCRETE BUILDING

Volume: 6 Number: 2 June 23, 2018
TR EN

THE EFFECTS OF A COLUMN DAMAGE TO STRUCTURAL BEHAVIOR OF AN EXAMPLE LOW-STRENGTH CONCRETE BUILDING

Abstract

In recent years, a new urban transformation process has been started to minimize the seismic hazard risk in Turkey. The main aim of this process is to avoid uncontrolled urbanization and faulty structuring by replacing old buildings with new seismic-resistant structures. Unfortunately, it brings new risks. The most important risk is formed with the damages which may occur on the adjacent buildings during the demolition. There are several cases and lawsuits reached to local authorities and courts about this issue. The main cause of these damages is the violation of the rules in regulations and ignorance of engineering principles related to demolition applications. In this study, a low-strength building in Istanbul is investigated which has been damaged by the demolition of an adjacent building. The effects of these damages to the seismic performance level of the building are analyzed with three different numerical models. Primarily, both seismic performance levels of undamaged and damaged states are evaluated using nonlinear analysis method. Furthermore, a new structural member is added to the analysis model using the damaged state’s results to strengthen the damaged zone. The local structural behavior of the damaged zone and overall seismic performance of the building are investigated by three different cases aforementioned above to assess the results of this kind of damages. As a result of this study, the necessary strengthening approach is revealed by means of strengthening the local damaged zone or whole structure to provide necessary seismic performance level of the low-strength buildings having this type of damages.

Keywords

References

  1. Afet Riski Altındaki Alanların Dönüştürülmesi Hakkında Kanun, 2012. Resmi Gazete.
  2. Aydınoğlu, N., 2003. Yapıların Deprem Performansının Değerlendirilmesi için Artımsal Spektrum Analizi Yöntemi. Beşinci Ulusal Deprem Mühendisliği Konferansı, İstanbul.
  3. Çoşgun, T, 2017. Yıkım çalışması nedeniyle örnek bir yapıda oluşan yapısal hasarlar ve bu hasarların performans seviyesine etkisi. Sakarya Üniversitesi Fen Bilimleri Enstitüsü Dergisi, 21 (5), 831~841.
  4. Çoşgun, T., Öztoprak, S., Öser, C., 2014. Uzman Görüşü Raporu, No: 2013/327, İstanbul.
  5. CSI, 2016. ETABS Integrated Building Design Software. Computers and Structures Inc., Berkeley, USA.
  6. CSI, 2017. Fiber hinge properties. CSI Knowledge Base. https://wiki.csiamerica.com/display/kb/Caltrans+vs.+fiber+hinge.
  7. Dinçer, F., Mert, N. 2014. Betonarme Okul Binasının TDY 2007’ye göre Nonlineer Statik Analizi. Sakarya Üniversitesi Fen Bilimleri Dergisi, 18 (1), 1-9.
  8. DİPU İnşaat Ltd. Şti., 2013. Nurettin Kaplan Deprem Risk Raporu.

Details

Primary Language

English

Subjects

Civil Engineering

Journal Section

Research Article

Publication Date

June 23, 2018

Submission Date

March 26, 2018

Acceptance Date

May 10, 2018

Published in Issue

Year 2018 Volume: 6 Number: 2

APA
Mangır, A., Çoşgun, T., & Güneş, B. (2018). THE EFFECTS OF A COLUMN DAMAGE TO STRUCTURAL BEHAVIOR OF AN EXAMPLE LOW-STRENGTH CONCRETE BUILDING. Mühendislik Bilimleri Ve Tasarım Dergisi, 6(2), 273-281. https://doi.org/10.21923/jesd.409763
AMA
1.Mangır A, Çoşgun T, Güneş B. THE EFFECTS OF A COLUMN DAMAGE TO STRUCTURAL BEHAVIOR OF AN EXAMPLE LOW-STRENGTH CONCRETE BUILDING. JESD. 2018;6(2):273-281. doi:10.21923/jesd.409763
Chicago
Mangır, Atakan, Turgay Çoşgun, and Barış Güneş. 2018. “THE EFFECTS OF A COLUMN DAMAGE TO STRUCTURAL BEHAVIOR OF AN EXAMPLE LOW-STRENGTH CONCRETE BUILDING”. Mühendislik Bilimleri Ve Tasarım Dergisi 6 (2): 273-81. https://doi.org/10.21923/jesd.409763.
EndNote
Mangır A, Çoşgun T, Güneş B (June 1, 2018) THE EFFECTS OF A COLUMN DAMAGE TO STRUCTURAL BEHAVIOR OF AN EXAMPLE LOW-STRENGTH CONCRETE BUILDING. Mühendislik Bilimleri ve Tasarım Dergisi 6 2 273–281.
IEEE
[1]A. Mangır, T. Çoşgun, and B. Güneş, “THE EFFECTS OF A COLUMN DAMAGE TO STRUCTURAL BEHAVIOR OF AN EXAMPLE LOW-STRENGTH CONCRETE BUILDING”, JESD, vol. 6, no. 2, pp. 273–281, June 2018, doi: 10.21923/jesd.409763.
ISNAD
Mangır, Atakan - Çoşgun, Turgay - Güneş, Barış. “THE EFFECTS OF A COLUMN DAMAGE TO STRUCTURAL BEHAVIOR OF AN EXAMPLE LOW-STRENGTH CONCRETE BUILDING”. Mühendislik Bilimleri ve Tasarım Dergisi 6/2 (June 1, 2018): 273-281. https://doi.org/10.21923/jesd.409763.
JAMA
1.Mangır A, Çoşgun T, Güneş B. THE EFFECTS OF A COLUMN DAMAGE TO STRUCTURAL BEHAVIOR OF AN EXAMPLE LOW-STRENGTH CONCRETE BUILDING. JESD. 2018;6:273–281.
MLA
Mangır, Atakan, et al. “THE EFFECTS OF A COLUMN DAMAGE TO STRUCTURAL BEHAVIOR OF AN EXAMPLE LOW-STRENGTH CONCRETE BUILDING”. Mühendislik Bilimleri Ve Tasarım Dergisi, vol. 6, no. 2, June 2018, pp. 273-81, doi:10.21923/jesd.409763.
Vancouver
1.Atakan Mangır, Turgay Çoşgun, Barış Güneş. THE EFFECTS OF A COLUMN DAMAGE TO STRUCTURAL BEHAVIOR OF AN EXAMPLE LOW-STRENGTH CONCRETE BUILDING. JESD. 2018 Jun. 1;6(2):273-81. doi:10.21923/jesd.409763