BibTex RIS Cite

Laser Doppler Flowmetrinin Önemi ve Kullanım Alanları

Year 2007, Volume: 8 Issue: 2, 45 - 48, 01.08.2007

Abstract

References

  • Adrian RJ.: Selected papers on laser Doppler velocimetry. II. Series. SPIE Optical Engineering Press. 1993.
  • Öberg PA.: Laser Doppler flowmetry. Crit Rev Biomed Eng. 1990;18(2):125-63.
  • Vongsavan N, Matthews B.: Some aspects of the use of laser Doppler flow meters for recording tissue blood flow. Exp. Physiol. 1993;78(1)1-14.
  • Humeau A, Steenbergn W, Nilsson H, Strömberg T.: Laser Doppler perfusion monitoring and imaging: novel approaches. Med Biol Eng Comput. 2007;45(5):421-35.
  • Matthews B, Vongsavan N.: Advantages and limitations of laser Doppler flow meters. Int Endod J. 1993;26(1):9-10.
  • Riva C, Ross B, Benedek GB.: Laser Doppler measurement of blood flow in capillary tubes and retinal arteries. Invest Ophthalmol. 1972;11(11):936- 44.
  • Ingólfsson AR, Tronstad L, Hersh EV, Riva CE.: Effect of probe design on the suitability of laser Doppler flowmetry in vitality testing of human. Endo Dent Traumatol. 1993;9(2):65-70.
  • Johansson K, Ahn H, Lindhagen J, Tryselius U.: Effect of epidural anaesthesia on intestinal blood flow. Br J Surg. 1988;75(1):73-6.
  • Hoffman U, Schneider E, Bollinger A.: Flow motion waves with high and low frequency in severe ischaemia before and after percutaneous transluminal angioplasty. Cardiovasc Res. 1990;24(9):711-8.
  • Choi CM, Bennett RG.: Laser Dopplers to determine cutaneous blood flow. Dermatol Surg. 2003; 29(3):272-80.
  • Fazekas A, Olgart L, Gazelius B, Kerezoudis N, Edwall L.: Effects of angiotensin II on blood flow in rat submandibular gland. Acta Physiol Scand. 1991;142(4):503-7.
  • Tooke JE, Ostergren J, Lins PE, Fagrell B.: Skin microvascular blood flow control in long duration diabetics with and without complications. Diabetes Res. 1987;5(4):189-92.
  • Staberg B, Serup J.: Allergic and irritant skin reactions evaluated by laser Doppler flowmetry. Contact Dermatitis. 1988;18(1):40-5.
  • Walmsley D, Goodfield MJ.: Evidence for an abnormal peripherally mediated vascular response to temperature in Raynaud’s phenomenon. Br J Rheumatol. 1990;29(3):181-4.
  • Limbird TJ.: Application of laser Doppler technology to meniscal injuries. Clin Orthop Relat Res. 1991;252:88-91.
  • Jenkins S, Sepka R, Barwick WJ.: Routine use of laser Doppler flowmetry for monitoring autologous tissue transplants. Ann Plast Surg. 1988;21(5):423-6.
  • Emshoff R, Moschen I, Strobl H.: Use of laser Doppler flowmetry to predict vitality of luxated or avulsed permanent teeth. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2004;98(6):750-5.
  • Vongsavan N, Matthews B.: Experiments on extracted teeth into the validity of using laser Doppler techniques for recording pulpal blood flow. Arch Oral Biol. 1993;38(5):431-9.
  • Baab DA, Öberg PA.: Laser Doppler measurement of gingival blood flow in dogs with increasing inflammation. Arch Oral Biol. 1987:32(8):551-5.
  • Ramsay DS, Artun J, Martinen SS.: Reliability of pulpal blood-flow measurements utilizing laser Doppler fIowmetry. J. Dent Res. 1991;70(11):1427- 30.
  • Wannfors K, Gazelius B.: Blood flow in jaw bones affected by chronic osteomyelitis. Br J Oral Maxillofac Surg. 1991;29(3):147-53.
  • Musselwhite JM, Klitzman B, Maixner W, Burkes EJ.: Laser Doppler fIowmetry: a clinical test of pulpal vitality. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 1997;84(4):411-9
  • Ikawa M, Komatsu H, Ikawa K, Mayanagi H, Shimauchi H.: Age-related changes in the human pulpal blood flow measured by laser Doppler flowmetry. Dent Traumatol. 2003;19:36-40.
  • Morozumi T, Kubota T, Sato T, Okuda K, Yoshie H.: Smoking cessation increases gingival blood flow and gingival crevicular fluid. J Clin Periodontol. 2004;31(4):267-72.

Laser Doppler Flowmetrinin Önemi ve Kullanım Alanları

Year 2007, Volume: 8 Issue: 2, 45 - 48, 01.08.2007

Abstract

Laser Doppler flowmetri (LDF) hareket halindeki nesneden yansıyan radyasyonun, frekansında oluşan Doppler kaymasının ölçülmesi temeline dayanan bir tekniktir. Doku kan akımının sürekli ve non invaziv ölçümü, düşük güçlü monokromatik laser ışını taşıyan optik probla sağlanabilir. Tıp ve dişhekimliği alanlarında deneysel amaçlı kullanılan LDF klinik alanlarda da kendine yaygın kullanım alanı bulmaya başlamıştır. Bu çalışmanın amacı, laser Doppler akım ölçümünün tıp ve dişhekimliğinde kullanım alanları, sağladığı avantaj, dezavantaj ve tekniğin sınırlı yanlarını ortaya koyarak, konunun daha kapsamlı değerlendirilmesine katkı sağlamaktır

References

  • Adrian RJ.: Selected papers on laser Doppler velocimetry. II. Series. SPIE Optical Engineering Press. 1993.
  • Öberg PA.: Laser Doppler flowmetry. Crit Rev Biomed Eng. 1990;18(2):125-63.
  • Vongsavan N, Matthews B.: Some aspects of the use of laser Doppler flow meters for recording tissue blood flow. Exp. Physiol. 1993;78(1)1-14.
  • Humeau A, Steenbergn W, Nilsson H, Strömberg T.: Laser Doppler perfusion monitoring and imaging: novel approaches. Med Biol Eng Comput. 2007;45(5):421-35.
  • Matthews B, Vongsavan N.: Advantages and limitations of laser Doppler flow meters. Int Endod J. 1993;26(1):9-10.
  • Riva C, Ross B, Benedek GB.: Laser Doppler measurement of blood flow in capillary tubes and retinal arteries. Invest Ophthalmol. 1972;11(11):936- 44.
  • Ingólfsson AR, Tronstad L, Hersh EV, Riva CE.: Effect of probe design on the suitability of laser Doppler flowmetry in vitality testing of human. Endo Dent Traumatol. 1993;9(2):65-70.
  • Johansson K, Ahn H, Lindhagen J, Tryselius U.: Effect of epidural anaesthesia on intestinal blood flow. Br J Surg. 1988;75(1):73-6.
  • Hoffman U, Schneider E, Bollinger A.: Flow motion waves with high and low frequency in severe ischaemia before and after percutaneous transluminal angioplasty. Cardiovasc Res. 1990;24(9):711-8.
  • Choi CM, Bennett RG.: Laser Dopplers to determine cutaneous blood flow. Dermatol Surg. 2003; 29(3):272-80.
  • Fazekas A, Olgart L, Gazelius B, Kerezoudis N, Edwall L.: Effects of angiotensin II on blood flow in rat submandibular gland. Acta Physiol Scand. 1991;142(4):503-7.
  • Tooke JE, Ostergren J, Lins PE, Fagrell B.: Skin microvascular blood flow control in long duration diabetics with and without complications. Diabetes Res. 1987;5(4):189-92.
  • Staberg B, Serup J.: Allergic and irritant skin reactions evaluated by laser Doppler flowmetry. Contact Dermatitis. 1988;18(1):40-5.
  • Walmsley D, Goodfield MJ.: Evidence for an abnormal peripherally mediated vascular response to temperature in Raynaud’s phenomenon. Br J Rheumatol. 1990;29(3):181-4.
  • Limbird TJ.: Application of laser Doppler technology to meniscal injuries. Clin Orthop Relat Res. 1991;252:88-91.
  • Jenkins S, Sepka R, Barwick WJ.: Routine use of laser Doppler flowmetry for monitoring autologous tissue transplants. Ann Plast Surg. 1988;21(5):423-6.
  • Emshoff R, Moschen I, Strobl H.: Use of laser Doppler flowmetry to predict vitality of luxated or avulsed permanent teeth. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2004;98(6):750-5.
  • Vongsavan N, Matthews B.: Experiments on extracted teeth into the validity of using laser Doppler techniques for recording pulpal blood flow. Arch Oral Biol. 1993;38(5):431-9.
  • Baab DA, Öberg PA.: Laser Doppler measurement of gingival blood flow in dogs with increasing inflammation. Arch Oral Biol. 1987:32(8):551-5.
  • Ramsay DS, Artun J, Martinen SS.: Reliability of pulpal blood-flow measurements utilizing laser Doppler fIowmetry. J. Dent Res. 1991;70(11):1427- 30.
  • Wannfors K, Gazelius B.: Blood flow in jaw bones affected by chronic osteomyelitis. Br J Oral Maxillofac Surg. 1991;29(3):147-53.
  • Musselwhite JM, Klitzman B, Maixner W, Burkes EJ.: Laser Doppler fIowmetry: a clinical test of pulpal vitality. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 1997;84(4):411-9
  • Ikawa M, Komatsu H, Ikawa K, Mayanagi H, Shimauchi H.: Age-related changes in the human pulpal blood flow measured by laser Doppler flowmetry. Dent Traumatol. 2003;19:36-40.
  • Morozumi T, Kubota T, Sato T, Okuda K, Yoshie H.: Smoking cessation increases gingival blood flow and gingival crevicular fluid. J Clin Periodontol. 2004;31(4):267-72.
There are 24 citations in total.

Details

Primary Language Turkish
Journal Section Articles
Authors

Ümit Karaçaylı This is me

Yılmaz Günaydın This is me

Publication Date August 1, 2007
Published in Issue Year 2007 Volume: 8 Issue: 2

Cite

APA Karaçaylı, Ü., & Günaydın, Y. (2007). Laser Doppler Flowmetrinin Önemi ve Kullanım Alanları. Kocatepe Tıp Dergisi, 8(2), 45-48. https://doi.org/10.18229/ktd.87319
AMA Karaçaylı Ü, Günaydın Y. Laser Doppler Flowmetrinin Önemi ve Kullanım Alanları. KTD. August 2007;8(2):45-48. doi:10.18229/ktd.87319
Chicago Karaçaylı, Ümit, and Yılmaz Günaydın. “Laser Doppler Flowmetrinin Önemi Ve Kullanım Alanları”. Kocatepe Tıp Dergisi 8, no. 2 (August 2007): 45-48. https://doi.org/10.18229/ktd.87319.
EndNote Karaçaylı Ü, Günaydın Y (August 1, 2007) Laser Doppler Flowmetrinin Önemi ve Kullanım Alanları. Kocatepe Tıp Dergisi 8 2 45–48.
IEEE Ü. Karaçaylı and Y. Günaydın, “Laser Doppler Flowmetrinin Önemi ve Kullanım Alanları”, KTD, vol. 8, no. 2, pp. 45–48, 2007, doi: 10.18229/ktd.87319.
ISNAD Karaçaylı, Ümit - Günaydın, Yılmaz. “Laser Doppler Flowmetrinin Önemi Ve Kullanım Alanları”. Kocatepe Tıp Dergisi 8/2 (August 2007), 45-48. https://doi.org/10.18229/ktd.87319.
JAMA Karaçaylı Ü, Günaydın Y. Laser Doppler Flowmetrinin Önemi ve Kullanım Alanları. KTD. 2007;8:45–48.
MLA Karaçaylı, Ümit and Yılmaz Günaydın. “Laser Doppler Flowmetrinin Önemi Ve Kullanım Alanları”. Kocatepe Tıp Dergisi, vol. 8, no. 2, 2007, pp. 45-48, doi:10.18229/ktd.87319.
Vancouver Karaçaylı Ü, Günaydın Y. Laser Doppler Flowmetrinin Önemi ve Kullanım Alanları. KTD. 2007;8(2):45-8.

88x31.png
Bu Dergi Creative Commons Atıf-GayriTicari-AynıLisanslaPaylaş 4.0 Uluslararası Lisansı ile lisanslanmıştır.