BibTex RIS Cite

THE EFFECTS OF VARIABLE AIR FLOW RATES ON THE SYSTEM PERFORMANCE WITHIN THE THERMOELECTRICAL MODULLED WATER COOLER

Year 2010, Volume: 5 Issue: 2, 131 - 143, 01.03.2010

Abstract

In this study, 1 kg water which is filled in the 1.5 liter volume container has been cooled by using in the size 40x40x3.8mm with the code TEC-12706 thermoelectrical module. The other fins of the module surface has been cooled by three variable air flow rate and it has been investigated that its performance effect on the system. Although high air flow rate increase of the module performance, it has reduced total performance of system because it has consumed more than necessary fan power.

TERMOELEKTRYK MODÜLLÜ SU SO?UTUCUSUNDA FARKLI HAVA DEBYLERYNYN SYSTEM PERFORMANSINA ETKYLERY

Year 2010, Volume: 5 Issue: 2, 131 - 143, 01.03.2010

Abstract

Bu çaly?mada, 1.5 litre hacmindeki hazne içerisine doldurulan 1 kg su, 40 x 40 x 3.8 mm boyutunda TEC–12706 kodlu termoelektrik modül vasytasyyla so?utulmu?tur. Modülün di?er yüzeyindeki kanatçyklary üç farkly hava debisi ile so?utularak sistem performansyna etkisi incelenmi?tir. Yüksek hava debisi, modülün performansyny arttyrmasyna ra?men daha fazla fan gücü harcanmasyna neden oldu?undan sistemin toplam performansyny dü?ürmektedir.

There are 0 citations in total.

Details

Primary Language Turkish
Journal Section Electrical Machines
Authors

Celil Yavuz This is me

Metin Kaya This is me

Mehmet Özkaymak This is me

Publication Date March 1, 2010
Published in Issue Year 2010 Volume: 5 Issue: 2

Cite

APA Yavuz, C., Kaya, M., & Özkaymak, M. (2010). TERMOELEKTRYK MODÜLLÜ SU SO?UTUCUSUNDA FARKLI HAVA DEBYLERYNYN SYSTEM PERFORMANSINA ETKYLERY. Technological Applied Sciences, 5(2), 131-143. https://doi.org/10.12739/10.12739
AMA Yavuz C, Kaya M, Özkaymak M. TERMOELEKTRYK MODÜLLÜ SU SO?UTUCUSUNDA FARKLI HAVA DEBYLERYNYN SYSTEM PERFORMANSINA ETKYLERY. Technological Applied Sciences. March 2010;5(2):131-143. doi:10.12739/10.12739
Chicago Yavuz, Celil, Metin Kaya, and Mehmet Özkaymak. “TERMOELEKTRYK MODÜLLÜ SU SO?UTUCUSUNDA FARKLI HAVA DEBYLERYNYN SYSTEM PERFORMANSINA ETKYLERY”. Technological Applied Sciences 5, no. 2 (March 2010): 131-43. https://doi.org/10.12739/10.12739.
EndNote Yavuz C, Kaya M, Özkaymak M (March 1, 2010) TERMOELEKTRYK MODÜLLÜ SU SO?UTUCUSUNDA FARKLI HAVA DEBYLERYNYN SYSTEM PERFORMANSINA ETKYLERY. Technological Applied Sciences 5 2 131–143.
IEEE C. Yavuz, M. Kaya, and M. Özkaymak, “TERMOELEKTRYK MODÜLLÜ SU SO?UTUCUSUNDA FARKLI HAVA DEBYLERYNYN SYSTEM PERFORMANSINA ETKYLERY”, Technological Applied Sciences, vol. 5, no. 2, pp. 131–143, 2010, doi: 10.12739/10.12739.
ISNAD Yavuz, Celil et al. “TERMOELEKTRYK MODÜLLÜ SU SO?UTUCUSUNDA FARKLI HAVA DEBYLERYNYN SYSTEM PERFORMANSINA ETKYLERY”. Technological Applied Sciences 5/2 (March 2010), 131-143. https://doi.org/10.12739/10.12739.
JAMA Yavuz C, Kaya M, Özkaymak M. TERMOELEKTRYK MODÜLLÜ SU SO?UTUCUSUNDA FARKLI HAVA DEBYLERYNYN SYSTEM PERFORMANSINA ETKYLERY. Technological Applied Sciences. 2010;5:131–143.
MLA Yavuz, Celil et al. “TERMOELEKTRYK MODÜLLÜ SU SO?UTUCUSUNDA FARKLI HAVA DEBYLERYNYN SYSTEM PERFORMANSINA ETKYLERY”. Technological Applied Sciences, vol. 5, no. 2, 2010, pp. 131-43, doi:10.12739/10.12739.
Vancouver Yavuz C, Kaya M, Özkaymak M. TERMOELEKTRYK MODÜLLÜ SU SO?UTUCUSUNDA FARKLI HAVA DEBYLERYNYN SYSTEM PERFORMANSINA ETKYLERY. Technological Applied Sciences. 2010;5(2):131-43.