Research Article

The Effect Of The Use Of Excessıve Dosages Of Plastıcızer On Propertıes Of Concrete

Volume: 25 Number: 1 June 30, 2012
EN TR

The Effect Of The Use Of Excessıve Dosages Of Plastıcızer On Propertıes Of Concrete

Abstract

In this study, the effect of the use of excessive dosages of normal and superplasticizer admixtures on the compressive strength and absorption properties of concrete was investigated. Normal plasticizer admixtures were used  0.5 %, 1 %, 5 % and 10 % by weight of cement and superplasticizer admixtures were used 1.5 %, 3 %, 5 %  and % 10 by weight of cement. Unit weight and slump tests were conducted on the fresh concretes and compressive strenght and water absorption tests  were conducted on the hardened concrete samples. Test results indicated that the use of excessive dosages of chemical admixtures significantly decreased compressive strength of concretes and extended demoulding time. Moreover, the best plasticizer proportion range was found 1 % - 1.5 %. Furthermore, water absorption values were obtained in the range of 1.95 % - 5.65 %.    

Keywords

concrete,chemical admixture,compressive stregth,water absorption

References

  1. [1] İ.B. Topçu, A. Demir, A.R. Boğa, „‟Akışkanlaştırıcı ve Süperakışkanlaştırıcı Katkı Kullanımının Taze Beton Özeliklerine Etkisi‟‟, Türkiye Mühendislik Haberleri, Sayı 434, ss.38-40, 2004.
  2. [2] İ.B. Topçu, “Akışkanlaştırıcı ve Dona Dayanım Katkılarının Beton Özeliklerine Etkisi”, 4. Ulusal Beton Kongresi, 30-31 Ekim- 1 Kasım 1996, İstanbul, ss. 45-53.
  3. [3] M. S. Akman, “Beton Katkı Maddelerinin Ana İşlevleri ve Yan Etkileri”, İTÜ İnşaat Fakültesi, Malzeme Seminerleri, 1987, İstanbul.
  4. [4 H. Yıldırım, V. Yorulmazel, E. Ardaç, “Süper ve Normal Akışkanlaştırıcı Katkıların Çimento ile Uyuşumu”, 4. Ulusal Beton Kongresi, 30-31 Ekim- 1 Kasım 1996, İstanbul, ss. 25-33.
  5. [5] V.S. Ramachandran, M. Malhotra, „’Concrete Admixtures Handbook-Part 7: Superplasticizers‟‟, Noyes Publications, pp. 462-63, 1984.
  6. [6] B. Felekoğlu, B. Baradan, „‟Akışkanlaştırıcı Katkıların Harçta Su Kesme PerformansıMukavemet İlişkisine Etkileri‟‟, İMO Teknik Dergi, Cilt 15, Sayı 2, ss. 3869-3872, 2006.
  7. [7] P.K. Mehta, P.J.M. Monteiro, ‘’Concrete Microstructure, Properties and Materials, Chapter 8: Admixtures‟‟, Indian Concrete Institute, Chennai, pp. 256-271, 1997.
  8. [8] S. Türkel, B. Felekoğlu, „‟Aşırı Dozda Akışkanlaştırıcı Kimyasal Katkı Kullanımının Taze ve Sertleşmiş Betonun Bazı Özellikleri Üzerine Etkileri‟‟, DEÜ Mühendislik Fakültesi Fen ve Mühendislik Dergisi, Cilt.6, Sayı., ss.79-91, 2004.
  9. [9] C.F. Ferraris, „‟Measurement of the Rheological Properties of High Performance Concrete: State of the Art Report‟‟, Journal of the National Institute of Standards and Technology, Vol.104, No.2, pp. 461-478, 1999.
  10. [10] T.A. Bürge, „‟Multi component Polymer Concrete‟‟, First International RILEM Symposium on Self-Compacting Concrete, 1999, Rilem Publications, S.A.R.L., pp. 411-424, 1999.
APA
Uysal, M., & Yılmaz, K. (2012). Aşırı Dozda Akışkanlaştırıcı Katkı Kullanımın Beton Özellikleri Etkisi. Eskişehir Osmangazi Üniversitesi Mühendislik Ve Mimarlık Fakültesi Dergisi, 25(1), 19-36. https://izlik.org/JA36XJ76KB
AMA
1.Uysal M, Yılmaz K. Aşırı Dozda Akışkanlaştırıcı Katkı Kullanımın Beton Özellikleri Etkisi. Eskişehir Osmangazi Üniversitesi Mühendislik ve Mimarlık Fakültesi Dergisi. 2012;25(1):19-36. https://izlik.org/JA36XJ76KB
Chicago
Uysal, Mücteba, and Kemalettin Yılmaz. 2012. “Aşırı Dozda Akışkanlaştırıcı Katkı Kullanımın Beton Özellikleri Etkisi”. Eskişehir Osmangazi Üniversitesi Mühendislik Ve Mimarlık Fakültesi Dergisi 25 (1): 19-36. https://izlik.org/JA36XJ76KB.
EndNote
Uysal M, Yılmaz K (June 1, 2012) Aşırı Dozda Akışkanlaştırıcı Katkı Kullanımın Beton Özellikleri Etkisi. Eskişehir Osmangazi Üniversitesi Mühendislik ve Mimarlık Fakültesi Dergisi 25 1 19–36.
IEEE
[1]M. Uysal and K. Yılmaz, “Aşırı Dozda Akışkanlaştırıcı Katkı Kullanımın Beton Özellikleri Etkisi”, Eskişehir Osmangazi Üniversitesi Mühendislik ve Mimarlık Fakültesi Dergisi, vol. 25, no. 1, pp. 19–36, June 2012, [Online]. Available: https://izlik.org/JA36XJ76KB
ISNAD
Uysal, Mücteba - Yılmaz, Kemalettin. “Aşırı Dozda Akışkanlaştırıcı Katkı Kullanımın Beton Özellikleri Etkisi”. Eskişehir Osmangazi Üniversitesi Mühendislik ve Mimarlık Fakültesi Dergisi 25/1 (June 1, 2012): 19-36. https://izlik.org/JA36XJ76KB.
JAMA
1.Uysal M, Yılmaz K. Aşırı Dozda Akışkanlaştırıcı Katkı Kullanımın Beton Özellikleri Etkisi. Eskişehir Osmangazi Üniversitesi Mühendislik ve Mimarlık Fakültesi Dergisi. 2012;25:19–36.
MLA
Uysal, Mücteba, and Kemalettin Yılmaz. “Aşırı Dozda Akışkanlaştırıcı Katkı Kullanımın Beton Özellikleri Etkisi”. Eskişehir Osmangazi Üniversitesi Mühendislik Ve Mimarlık Fakültesi Dergisi, vol. 25, no. 1, June 2012, pp. 19-36, https://izlik.org/JA36XJ76KB.
Vancouver
1.Mücteba Uysal, Kemalettin Yılmaz. Aşırı Dozda Akışkanlaştırıcı Katkı Kullanımın Beton Özellikleri Etkisi. Eskişehir Osmangazi Üniversitesi Mühendislik ve Mimarlık Fakültesi Dergisi [Internet]. 2012 Jun. 1;25(1):19-36. Available from: https://izlik.org/JA36XJ76KB