BibTex RIS Cite

FUZZY LOGIC CONTROLLED SWITCHED RELUCTANCE MOTOR DRIVER DESIGNING FOR A LIFT SYSTEM

Year 2006, Volume: 12 Issue: 2, 151 - 160, 01.02.2006

Abstract

In this study, a 8/6 poles, four phases, 3.44 kW switched reluctance motor driver was used for a elavator load. For this aim, it has been designed a swithed reluctance motor driver for a lift system. At the driver system was used a buck konverter. The speed was controlled by motor phase voltage control. The voltage value has been controlled with fuzzy logic controller by using TMS320LF2407 controller. Fuzzy controlled switched reluctance motor was used for a elavator load by using designed driver system.

BİR ASANSÖR TAHRİK SİSTEMİ İÇİN BULANIK MANTIK DENETİMLİ ANAHTARLAMALI RELÜKTANS MOTOR SÜRÜCÜSÜ TASARIMI

Year 2006, Volume: 12 Issue: 2, 151 - 160, 01.02.2006

Abstract

Bu çalışmada, 8/6 kutuplu, 4 fazlı, 3.44 kW gücündeki bir anahtarlamalı relüktans motor asansör yükünde kullanılmıştır. Oluşturulan model asansör sistemi için bir sürücü tasarlanmış ve sürme sisteminde TMS320LF2407 sayısal sinyal işlemcisi kullanılmıştır. Tasarımı tamamlanan sürücü, bulanık mantık yöntemi kullanılarak hız denetim algoritması oluşturulan anahtarlamalı relüktans motor asansör yükü altında çalıştırılmıştır.

There are 0 citations in total.

Details

Primary Language Turkish
Journal Section Research Article
Authors

Mahir Dursun This is me

Ali Saygın This is me

Publication Date February 1, 2006
Published in Issue Year 2006 Volume: 12 Issue: 2

Cite

APA Dursun, M. ., & Saygın, A. . (2006). BİR ASANSÖR TAHRİK SİSTEMİ İÇİN BULANIK MANTIK DENETİMLİ ANAHTARLAMALI RELÜKTANS MOTOR SÜRÜCÜSÜ TASARIMI. Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi, 12(2), 151-160.
AMA Dursun M, Saygın A. BİR ASANSÖR TAHRİK SİSTEMİ İÇİN BULANIK MANTIK DENETİMLİ ANAHTARLAMALI RELÜKTANS MOTOR SÜRÜCÜSÜ TASARIMI. Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi. February 2006;12(2):151-160.
Chicago Dursun, Mahir, and Ali Saygın. “BİR ASANSÖR TAHRİK SİSTEMİ İÇİN BULANIK MANTIK DENETİMLİ ANAHTARLAMALI RELÜKTANS MOTOR SÜRÜCÜSÜ TASARIMI”. Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi 12, no. 2 (February 2006): 151-60.
EndNote Dursun M, Saygın A (February 1, 2006) BİR ASANSÖR TAHRİK SİSTEMİ İÇİN BULANIK MANTIK DENETİMLİ ANAHTARLAMALI RELÜKTANS MOTOR SÜRÜCÜSÜ TASARIMI. Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi 12 2 151–160.
IEEE M. . Dursun and A. . Saygın, “BİR ASANSÖR TAHRİK SİSTEMİ İÇİN BULANIK MANTIK DENETİMLİ ANAHTARLAMALI RELÜKTANS MOTOR SÜRÜCÜSÜ TASARIMI”, Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi, vol. 12, no. 2, pp. 151–160, 2006.
ISNAD Dursun, Mahir - Saygın, Ali. “BİR ASANSÖR TAHRİK SİSTEMİ İÇİN BULANIK MANTIK DENETİMLİ ANAHTARLAMALI RELÜKTANS MOTOR SÜRÜCÜSÜ TASARIMI”. Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi 12/2 (February 2006), 151-160.
JAMA Dursun M, Saygın A. BİR ASANSÖR TAHRİK SİSTEMİ İÇİN BULANIK MANTIK DENETİMLİ ANAHTARLAMALI RELÜKTANS MOTOR SÜRÜCÜSÜ TASARIMI. Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi. 2006;12:151–160.
MLA Dursun, Mahir and Ali Saygın. “BİR ASANSÖR TAHRİK SİSTEMİ İÇİN BULANIK MANTIK DENETİMLİ ANAHTARLAMALI RELÜKTANS MOTOR SÜRÜCÜSÜ TASARIMI”. Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi, vol. 12, no. 2, 2006, pp. 151-60.
Vancouver Dursun M, Saygın A. BİR ASANSÖR TAHRİK SİSTEMİ İÇİN BULANIK MANTIK DENETİMLİ ANAHTARLAMALI RELÜKTANS MOTOR SÜRÜCÜSÜ TASARIMI. Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi. 2006;12(2):151-60.

ESCI_LOGO.png    image001.gif    image002.gif        image003.gif     image004.gif