BibTex RIS Cite
Year 2016, Volume: 19 Issue: 4, 617 - 622, 01.12.2016

Abstract

An Investigation on Shielding Effect of Bismuth on Lung Ct Scan Using Monte Carlo Simulation

Year 2016, Volume: 19 Issue: 4, 617 - 622, 01.12.2016

Abstract

Computed tomography (CT) related to computer-processed combination or X-ray images obtained from different angles to create patient’s cross-sectional body parts images. CT is mostly associated with high radiation dose to organs during the diagnostic process. To provide the probable effect of bismuth shielding on dose reduction to organs and investigation of applicability of Monte Carlo (MC) method. Monte Carlo (MC) method has been used for calculation of dose attenuation properties of bismuth. MCNPX (version 2.4.0) has been used during the calculations. In this study, validation of modeled MCNPX simulation geometry has been provided by calculating the mass attenuation coefficient values of lung and comparing with previous available studies in literature for lung. Our results agreed well with other results about mass attenuation coefficients of lung. By using the validated MC model, dose attenuation properties of bismuth have been investigated. Dose reduction rates of bismuth on lung have been compared with experimental studies. With bismuth shielding, absorbed dose amount in lung significantly reduced. It can be concluded from MC results that the bismuth shielding reduced lung dose significantly in x-ray CT examination of thorax region

There are 0 citations in total.

Details

Other ID JA95KR44PB
Journal Section Research Article
Authors

Hüseyin Ozan Tekin This is me

Tugba Manici This is me

Vishwanath P. Sıngh This is me

Publication Date December 1, 2016
Submission Date December 1, 2016
Published in Issue Year 2016 Volume: 19 Issue: 4

Cite

APA Tekin, H. O., Manici, T., & Sıngh, V. P. (2016). An Investigation on Shielding Effect of Bismuth on Lung Ct Scan Using Monte Carlo Simulation. Politeknik Dergisi, 19(4), 617-622.
AMA Tekin HO, Manici T, Sıngh VP. An Investigation on Shielding Effect of Bismuth on Lung Ct Scan Using Monte Carlo Simulation. Politeknik Dergisi. December 2016;19(4):617-622.
Chicago Tekin, Hüseyin Ozan, Tugba Manici, and Vishwanath P. Sıngh. “An Investigation on Shielding Effect of Bismuth on Lung Ct Scan Using Monte Carlo Simulation”. Politeknik Dergisi 19, no. 4 (December 2016): 617-22.
EndNote Tekin HO, Manici T, Sıngh VP (December 1, 2016) An Investigation on Shielding Effect of Bismuth on Lung Ct Scan Using Monte Carlo Simulation. Politeknik Dergisi 19 4 617–622.
IEEE H. O. Tekin, T. Manici, and V. P. Sıngh, “An Investigation on Shielding Effect of Bismuth on Lung Ct Scan Using Monte Carlo Simulation”, Politeknik Dergisi, vol. 19, no. 4, pp. 617–622, 2016.
ISNAD Tekin, Hüseyin Ozan et al. “An Investigation on Shielding Effect of Bismuth on Lung Ct Scan Using Monte Carlo Simulation”. Politeknik Dergisi 19/4 (December 2016), 617-622.
JAMA Tekin HO, Manici T, Sıngh VP. An Investigation on Shielding Effect of Bismuth on Lung Ct Scan Using Monte Carlo Simulation. Politeknik Dergisi. 2016;19:617–622.
MLA Tekin, Hüseyin Ozan et al. “An Investigation on Shielding Effect of Bismuth on Lung Ct Scan Using Monte Carlo Simulation”. Politeknik Dergisi, vol. 19, no. 4, 2016, pp. 617-22.
Vancouver Tekin HO, Manici T, Sıngh VP. An Investigation on Shielding Effect of Bismuth on Lung Ct Scan Using Monte Carlo Simulation. Politeknik Dergisi. 2016;19(4):617-22.