Location Analysis of Transient Surge Maneuver resulting from the Six Power Cables : The Impact of cable length and Shunt Reactors

Year 1997, Volume: 1 Issue: 2, 119 - 124, 01.12.1997

Abstract

-

Yer Altı Enerji Kablolarından Oluşan Manevra Aşırı Gerilimlerinin Geçici Rejim Analizi: Kablo Uzunluğunun Ve Şönt Reaktörlerin Etkisi

Year 1997, Volume: 1 Issue: 2, 119 - 124, 01.12.1997

Abstract

Bu çalışmada, yeraltı enerji kablosonda anabtann kaptoması esıumnda kablo başında ve kablo sonunda meydana gelen geçici aşın gerilimlerin maksimunı genlikleri ve dalga bilgisayar yardımıyla elde edilmiştir. Geçici aşın geıilimler önce fıekans domeninde elde edilmiş daha sonra ters fourier dönüşüm tekniği kuJiauılar zaman domeninde elde edilmiştir

There are 0 citations in total.

Details

Primary Language TR
Subjects Engineering
Journal Section Research Articles
Authors

Yılmaz Uyaroğlu This is me

M. Ünver This is me

Publication Date December 1, 1997
Submission Date May 7, 1997
Published in Issue Year 1997 Volume: 1 Issue: 2

Cite

APA Uyaroğlu, Y., & Ünver, M. (1997). Location Analysis of Transient Surge Maneuver resulting from the Six Power Cables : The Impact of cable length and Shunt Reactors. Sakarya University Journal of Science, 1(2), 119-124. https://doi.org/10.16984/saufbed.38578
AMA Uyaroğlu Y, Ünver M. Location Analysis of Transient Surge Maneuver resulting from the Six Power Cables : The Impact of cable length and Shunt Reactors. SAUJS. December 1997;1(2):119-124. doi:10.16984/saufbed.38578
Chicago Uyaroğlu, Yılmaz, and M. Ünver. “Location Analysis of Transient Surge Maneuver Resulting from the Six Power Cables : The Impact of Cable Length and Shunt Reactors”. Sakarya University Journal of Science 1, no. 2 (December 1997): 119-24. https://doi.org/10.16984/saufbed.38578.
EndNote Uyaroğlu Y, Ünver M (December 1, 1997) Location Analysis of Transient Surge Maneuver resulting from the Six Power Cables : The Impact of cable length and Shunt Reactors. Sakarya University Journal of Science 1 2 119–124.
IEEE Y. Uyaroğlu and M. Ünver, “Location Analysis of Transient Surge Maneuver resulting from the Six Power Cables : The Impact of cable length and Shunt Reactors”, SAUJS, vol. 1, no. 2, pp. 119–124, 1997, doi: 10.16984/saufbed.38578.
ISNAD Uyaroğlu, Yılmaz - Ünver, M. “Location Analysis of Transient Surge Maneuver Resulting from the Six Power Cables : The Impact of Cable Length and Shunt Reactors”. Sakarya University Journal of Science 1/2 (December 1997), 119-124. https://doi.org/10.16984/saufbed.38578.
JAMA Uyaroğlu Y, Ünver M. Location Analysis of Transient Surge Maneuver resulting from the Six Power Cables : The Impact of cable length and Shunt Reactors. SAUJS. 1997;1:119–124.
MLA Uyaroğlu, Yılmaz and M. Ünver. “Location Analysis of Transient Surge Maneuver Resulting from the Six Power Cables : The Impact of Cable Length and Shunt Reactors”. Sakarya University Journal of Science, vol. 1, no. 2, 1997, pp. 119-24, doi:10.16984/saufbed.38578.
Vancouver Uyaroğlu Y, Ünver M. Location Analysis of Transient Surge Maneuver resulting from the Six Power Cables : The Impact of cable length and Shunt Reactors. SAUJS. 1997;1(2):119-24.