Research Article
BibTex RIS Cite

LiF:MgCuNaSi Termolüminesans Dedektörün Farklı Enerjilerdeki Fotonlara Karşı Dedektör Cevap Fonksiyonun Monte Carlo Yöntemiyle İncelenmesi

Year 2014, Volume: 9 Issue: 2, 177 - 185, 31.12.2014

Abstract

Many of the Thermoluminescence (TL) dosimeters are used in different areas in order to measure “personnel dose equivalent”. It’s analyzes must be done by determining different dosimetric characteristics and specialty of TL the material. Obtaining data which supplies energy dependence of the detector response function for TL supplies is very difficult when experimental methods are used and can be measured with a large error value. It’s possible to get the detailed information when these detectors are modeled at computers. In this study, LiF materials which are used as “TLD” doped with Mg, Cu, Na, and Si activators are modeled. TL dosimeter detector response function of the energy dependence has been found by the method of the MCNP Monte Carlo simulation method. In previous studies with the results obtained have been compared with the values obtained in this study

References

  • Tsoulfanidis N., 1983. Measurement and Detection of Radiation, Hemisphere Publishing Corporation, New York, p. 571.
  • Moscovitch M., St. John T.J., Cassata J.R., Blake P.K., Rotunda J.E., Ramlo M., Velbeck K.J., Luo Z., 2006. The application of LiF:Mg,Cu,P to large scale personnel dosimetry: Current status and future directions, Radiation Protection Dosimetry, 119(1-4):248-254.
  • Freire L., Calado A., Cardoso J.V., Santos L.M., Alves J.G., 2008. Comparison of LiF (TLD-100 and TLD-100H) detectors for extremity monitoring, Radiation Measurements, 43: 646–650.
  • Şarer B., Hançerlioğulları A., Übeyli M., 2003. Nükleer Hesaplamalarda Monte Carlo Yönteminin Kullanımı, 8. Ulusal Nükleer Bilimler ve Teknolojiler Kongresi, Ekim 2003, Kayseri.
  • Briesmeister, J.F., Editor, 2000. MCNP- A General Monte Carlo N-Particle Transport Code System. LA-12625-M, Version C
  • Horowits Y.S., 1981. Thetheorical and microdosimetric basis of thermolüminescence and applications
  • to dosimetry, Physical Medical Biology, 26, 4, 765-824.
  • Das R.K., Li Z., Perera H., Williamson J.F., 1996.Accuracy of Monte Carlo photon transport simulation in characterizing brachytherapy dosimeter energy-response artefacts, Physical Medical Biology, 41: 995-1006.
  • Jung, H., Lee, K.J., and Kim, J.L., 2003. A personal thermoluminescence dosimeter using LiF:Mg,Cu,Na,Si detectors for photon Şelds, Applied Radiation and Isotopes, 59: 87–93.
  • Hranitzky C., Stadtmann H., Olko P., 2006. Determination of LiF:Mg,Ti and LiF:Mg,Cu,P TL efficiency for x-rays and their application to Monte Carlo simulations of dosimeter response, Radiation Protection Dosimetry, 119(1–4): 483–486.
  • Mehmet N. Kumru e-posta: mehmet.nurullah.kumru@ege.edu.tr
  • Gültekin Yeğin e-posta: gultekin.yegin@bayar.edu.tr
  • M. Mustafa Aydın e-posta: mma-95@hotmail.com

LiF:MgCuNaSi Termolüminesans Dedektörün Farklı Enerjilerdeki Fotonlara Karşı Dedektör Cevap Fonksiyonun Monte Carlo Yöntemiyle İncelenmesi

Year 2014, Volume: 9 Issue: 2, 177 - 185, 31.12.2014

Abstract

Özet: Birçok Termolüminesanas (TL) dozimetreleri “personel doz eşdeğerini” ölçmek için farklı alanlarda kullanılmaktadır. TL malzemelerin değişik dozimetrik özelliklerinin ve karakteristiklerinin belirlenerek analizlerinin yapılması gerekmektedir. TL malzemeleri için dedektör cevap fonksiyonlarının enerjiye bağlılığını veren verileri elde etmek, deneysel yöntemler kullanıldığında oldukça güçtür ve büyük hata değerleriyle birlikte ölçülebilmektedir. Bu dedektörler, bilgisayar ortamında modellendiğinde ayrıntılı bilgi almak mümkün olabilmektedir. Bu çalışmada, Mg, Cu, Na ve Si ile katkılanmış TLD olarak kullanılan LiF malzemeleri modellenmiştir. TL dozimetrelerin dedektör cevap fonksiyonlarının enerjiye bağlılığı MCNP Monte Carlo simülasyon yöntemi ile bulunmuştur. Önceden yapılmış çalışmalardan elde edilen sonuçlar ile bu çalışmada elde edilen değerler karşılaştırılmıştır.

Anahtar kelimeler: LiF, Monte Carlo, TL, foton

The Investigation of The Detector Response Function of The LiF:MgCuNaSi Thermoluminescence Detector Against The Photons In Different Energies By Using Monte Carlo Method

Abstract: Many of the Thermoluminescence (TL) dosimeters are used in different areas in order to measure “personnel dose equivalent”. It's analyzes must be done by determining different dosimetric characteristics and specialty of TL the material. Obtaining data which supplies energy dependence of the detector response function for TL supplies is very difficult when experimental methods are used and can be measured with a large error value. It's possible to get the detailed information when these detectors are modeled at computers. In this study, LiF materials which are used as “TLD” doped with Mg, Cu, Na, and Si activators are modeled. TL dosimeter detector response function of the energy dependence has been found by the method of the MCNP Monte Carlo simulation method. In previous studies with the results obtained have been compared with the values obtained in this study.

Key words: LiF, Monte Carlo, TL, photon

References

  • Tsoulfanidis N., 1983. Measurement and Detection of Radiation, Hemisphere Publishing Corporation, New York, p. 571.
  • Moscovitch M., St. John T.J., Cassata J.R., Blake P.K., Rotunda J.E., Ramlo M., Velbeck K.J., Luo Z., 2006. The application of LiF:Mg,Cu,P to large scale personnel dosimetry: Current status and future directions, Radiation Protection Dosimetry, 119(1-4):248-254.
  • Freire L., Calado A., Cardoso J.V., Santos L.M., Alves J.G., 2008. Comparison of LiF (TLD-100 and TLD-100H) detectors for extremity monitoring, Radiation Measurements, 43: 646–650.
  • Şarer B., Hançerlioğulları A., Übeyli M., 2003. Nükleer Hesaplamalarda Monte Carlo Yönteminin Kullanımı, 8. Ulusal Nükleer Bilimler ve Teknolojiler Kongresi, Ekim 2003, Kayseri.
  • Briesmeister, J.F., Editor, 2000. MCNP- A General Monte Carlo N-Particle Transport Code System. LA-12625-M, Version C
  • Horowits Y.S., 1981. Thetheorical and microdosimetric basis of thermolüminescence and applications
  • to dosimetry, Physical Medical Biology, 26, 4, 765-824.
  • Das R.K., Li Z., Perera H., Williamson J.F., 1996.Accuracy of Monte Carlo photon transport simulation in characterizing brachytherapy dosimeter energy-response artefacts, Physical Medical Biology, 41: 995-1006.
  • Jung, H., Lee, K.J., and Kim, J.L., 2003. A personal thermoluminescence dosimeter using LiF:Mg,Cu,Na,Si detectors for photon Şelds, Applied Radiation and Isotopes, 59: 87–93.
  • Hranitzky C., Stadtmann H., Olko P., 2006. Determination of LiF:Mg,Ti and LiF:Mg,Cu,P TL efficiency for x-rays and their application to Monte Carlo simulations of dosimeter response, Radiation Protection Dosimetry, 119(1–4): 483–486.
  • Mehmet N. Kumru e-posta: mehmet.nurullah.kumru@ege.edu.tr
  • Gültekin Yeğin e-posta: gultekin.yegin@bayar.edu.tr
  • M. Mustafa Aydın e-posta: mma-95@hotmail.com
There are 13 citations in total.

Details

Primary Language Turkish
Subjects Metrology, Applied and Industrial Physics
Journal Section Makaleler
Authors

Bünyamin Aydın This is me

Mehmet N. Kumru

Gültekin Yeğin This is me

M. Mustafa Aydın This is me

Publication Date December 31, 2014
Published in Issue Year 2014 Volume: 9 Issue: 2

Cite

IEEE B. Aydın, M. N. Kumru, G. Yeğin, and M. M. Aydın, “LiF:MgCuNaSi Termolüminesans Dedektörün Farklı Enerjilerdeki Fotonlara Karşı Dedektör Cevap Fonksiyonun Monte Carlo Yöntemiyle İncelenmesi”, Süleyman Demirel University Faculty of Arts and Science Journal of Science, vol. 9, no. 2, pp. 177–185, 2014.