Li2B4O7:Cu Termolüminesans Dedektörün Farklı Enerjilerdeki Fotonlara Karşı Dedektör Cevap Fonksiyonunun Monte Carlo Yöntemiyle İncelenmesi

Year 2014, Volume: 9 Issue: 2, 186 - 193, 31.12.2014

Abstract

Many of the Thermoluminescence dosimeters (TLD) are used in different areas in order to measure “personnel dose equivalent”. It’s analyzes must be done by determining different dosimetric characteristics and specialty of TL the material. Obtaining data which supplies energy dependence of the detector response function for TL supplies is very difficult when experimental methods are used and can be measured with a large error value. It’s possible to get the detailed information when these detectors are modeled at computers. In this study, Li2B4O7 material which is used as “TLD” doped with Cu activator is modeled. Directional photon sources, in different distances TL dosimeter detector response function of the energy dependence has been found by the method of the MCNP Monte Carlo simulation method. In previous studies with the results obtained have been compared with the values obtained in this study

References

  • Tsoulfanidis, N., 1983. Measurement and Detection of Radiation, Hemisphere Publishing Corporation, New York, p. 571.
  • Hançerlioğulları A., 2006. Monte Carlo Simülasyon Metodu ve MCNP Kod Sistemi, Kastamonu Education Journal, 14(2):545-546.
  • Briesmeister J.F., Editor 2000. MCNP- A General Monte Carlo N-Particle Transport Code System. LA-12625-M, Version C.
  • Horowits Y.S., 1981. Thetheorical and microdosimetric basis of thermolüminescence and applications to dosimetry, Physical Medical Biology, 26(4): 765-824.
  • Prokic, M., 2002. Dosimetric characteristics of Li2B4O7:Cu,Ag,P solid TL detectors, Radiation Protection Dosimetry, 100(1-4): 265-268.
  • Hranitzky C., Stadtmann H., Olko P., 2006. Determination of LiF:Mg,Ti and LiF:Mg,Cu,P TL efficiency for x-rays and their application to Monte Carlo simulations of dosemeter response, Radiation Protection Dosimetry, 119(1–4): 483–486.
  • Jung H., Lee K.J., Kim, J.L., 2003. A personal thermoluminescence dosimeter using LiF:Mg,Cu,Na,Si detectors for photon Şelds, Applied Radiation and Isotopes, 59, 87–93pp.
  • Daros K.A.C., Campos L.L., Medeiros R.B., 2001. TL response study of the CaSO4:Dy. Pellets with graphite for dosimetry in beta radiation and low-energy photons fields. Applied Radiation and Isotopes, 54: 957–960.
  • Furetta C., Prokic M., Salamon R., Prokic V., Kitis G., 2001. Dosimetric characteristics of tissue equivalent thermoluminescent solid TL detectors based on lithium borate, Nuclear Instruments and Methods in Physics Research A, 546: 411-417.
  • M. Mustafa Aydın e-posta: : mma-95@hotmail.com

Li2B4O7:Cu Termolüminesans Dedektörün Farklı Enerjilerdeki Fotonlara Karşı Dedektör Cevap Fonksiyonunun Monte Carlo Yöntemiyle İncelenmesi

Year 2014, Volume: 9 Issue: 2, 186 - 193, 31.12.2014

Abstract

Özet: Birçok Termolüminesanas Dozimetreleri (TLD) “personel doz eşdeğerini” ölçmek için farklı alanlarda kullanılmaktadır. TL malzemelerin değişik dozimetrik özelliklerinin ve karakteristiklerinin belirlenerek analizlerinin yapılması gerekmektedir. TL malzemeleri için dedektör cevap fonksiyonlarının enerjiye bağlılığını veren verileri elde etmek, deneysel yöntemler kullanıldığında oldukça güçtür ve büyük hata değerleriyle birlikte ölçülebilmektedir. Bu dedektörler, bilgisayar ortamında modellendiğinde ayrıntılı bilgi almak mümkün olabilmektedir. Bu çalışmada, Cu ile katkılanmış TLD olarak kullanılan Li2B4O7 malzemesi modellenmiştir. Yönlü foton kaynaklarından, farklı uzaklıklardaki TL dozimetrelerin dedektör cevap fonksiyonlarının enerjiye bağlılığı MCNP Monte Carlo simülasyon yöntemi ile bulunmuştur. Önceden yapılmış çalışmalardan elde edilen sonuçlar ile bu çalışmada elde edilen değerler karşılaştırılmıştır.

Anahtar kelimeler: Monte Carlo, Li2B4O7:Cu, TL, foton

The Investigation of The Detector Response Function of The Li2B4O7:Cu Thermoluminescence Detector Against The Photons In Different Energies By Using Monte Carlo Method

Abstract: Many of the Thermoluminescence dosimeters (TLD) are used in different areas in order to measure “personnel dose equivalent”. It's analyzes must be done by determining different dosimetric characteristics and specialty of TL the material. Obtaining data which supplies energy dependence of the detector response function for TL supplies is very difficult when experimental methods are used and can be measured with a large error value. It's possible to get the detailed information when these detectors are modeled at computers. In this study, Li2B4O7 material which is used as “TLD” doped with Cu activator is modeled. Directional photon sources, in different distances TL dosimeter detector response function of the energy dependence has been found by the method of the MCNP Monte Carlo simulation method. In previous studies with the results obtained have been compared with the values obtained in this study.

Key words: Monte Carlo, Li2B4O7:Cu, TL, foton

References

  • Tsoulfanidis, N., 1983. Measurement and Detection of Radiation, Hemisphere Publishing Corporation, New York, p. 571.
  • Hançerlioğulları A., 2006. Monte Carlo Simülasyon Metodu ve MCNP Kod Sistemi, Kastamonu Education Journal, 14(2):545-546.
  • Briesmeister J.F., Editor 2000. MCNP- A General Monte Carlo N-Particle Transport Code System. LA-12625-M, Version C.
  • Horowits Y.S., 1981. Thetheorical and microdosimetric basis of thermolüminescence and applications to dosimetry, Physical Medical Biology, 26(4): 765-824.
  • Prokic, M., 2002. Dosimetric characteristics of Li2B4O7:Cu,Ag,P solid TL detectors, Radiation Protection Dosimetry, 100(1-4): 265-268.
  • Hranitzky C., Stadtmann H., Olko P., 2006. Determination of LiF:Mg,Ti and LiF:Mg,Cu,P TL efficiency for x-rays and their application to Monte Carlo simulations of dosemeter response, Radiation Protection Dosimetry, 119(1–4): 483–486.
  • Jung H., Lee K.J., Kim, J.L., 2003. A personal thermoluminescence dosimeter using LiF:Mg,Cu,Na,Si detectors for photon Şelds, Applied Radiation and Isotopes, 59, 87–93pp.
  • Daros K.A.C., Campos L.L., Medeiros R.B., 2001. TL response study of the CaSO4:Dy. Pellets with graphite for dosimetry in beta radiation and low-energy photons fields. Applied Radiation and Isotopes, 54: 957–960.
  • Furetta C., Prokic M., Salamon R., Prokic V., Kitis G., 2001. Dosimetric characteristics of tissue equivalent thermoluminescent solid TL detectors based on lithium borate, Nuclear Instruments and Methods in Physics Research A, 546: 411-417.
  • M. Mustafa Aydın e-posta: : mma-95@hotmail.com
There are 10 citations in total.

Details

Primary Language Turkish
Subjects Metrology, Applied and Industrial Physics
Journal Section Makaleler
Authors

Bünyamin Aydın This is me

M. Mustafa Aydın This is me

Publication Date December 31, 2014
Published in Issue Year 2014 Volume: 9 Issue: 2

Cite

IEEE B. Aydın and M. M. Aydın, “Li2B4O7:Cu Termolüminesans Dedektörün Farklı Enerjilerdeki Fotonlara Karşı Dedektör Cevap Fonksiyonunun Monte Carlo Yöntemiyle İncelenmesi”, Süleyman Demirel University Faculty of Arts and Science Journal of Science, vol. 9, no. 2, pp. 186–193, 2014.