EN
TR
Comparison of conventional and digital cepholometric measurements methods
Abstract
Objective: The aim of this study were to compare the measurements obtained conventionally and digital drawings by two researchers, as well as researchers between two different drawings.
Material-Method: 60 lateral cephalometric radiographs were randomly selected and 5 linear and 14 angular parameters were traced and measured by two examiners using the conventional method and Quick Ceph studio program on each radiograph. Independent samples was used to compare the mean values of intra-examiner differences. Intraclass correlation coefficients (ICC) were calculated to determine intra- and inter-examiner correlation.
Results: Both operators were generally consistent in the repeated measurements; however, for one examiner, the difference for nasolabial angle measurements were found to be statistically significant(p<0.05). Intra-examiner and inter- examiner repeatabilities of measurements both with the manual and Quick Ceph techniques showed high correlation coefficients.
Conclusion: The findings showed that the use of computer- assisted cephalometric analysis carried out on scanned images does not increase the measurement error when compared with conventional technique.
Key words: Cephalometry, Digital radiography, Diagnosis
Keywords
References
- Brodie AG. On the growth pattern of the human head from the third month to the eighth year of life . Am J Anat 1941; 68: 209-262.
- Baumrind S, Frantz RC. The reliability of head film measurements 1. Landmark identification . Am J Orthod. 1971a; 60: 111–127.
- Baumrind S , Frantz RC. The reliability of head film measurements 2. Conventional angular and linear measures. Am J Orthod. 1971b; 60: 505–517.
- Ricketts RM. Perspectives in clinical application of cephalometrics. Angle Orthod. 1981; 51: 115–150.
- Liu JK, Chen YT, Cheng KS. Accuracy of computerized automatic identification of cephalometric landmarks. Am J Orthod Dentofacial Orthop. 2000; 118: 535–540.
- Chen SK, Chen YJ, Yao CC, Chang HF. Enhanced speed and precision of measurement in a computer-assisted digitalcephalometric analysis system. Angle Orthod. 2004a; 74: 501–507.
- Björk A, Solow B. Measurements on radiographs . J Dent Res. 1961; 41: 672–683.
- Houston WJB, Maher RE, McElroy D, Sherriff M. Sources of errorin measurements from cephalometric radiographs . Eur J Orthod. 1986; 8: 149–151.
Details
Primary Language
English
Subjects
-
Journal Section
-
Publication Date
January 7, 2015
Submission Date
April 8, 2014
Acceptance Date
-
Published in Issue
Year 2014 Volume: 5 Number: 3
APA
Akın, M., Tezcan, M., & İleri, Z. (2015). Comparison of conventional and digital cepholometric measurements methods. Süleyman Demirel Üniversitesi Sağlık Bilimleri Dergisi, 5(3), 94-97. https://izlik.org/JA42UR82DY
AMA
1.Akın M, Tezcan M, İleri Z. Comparison of conventional and digital cepholometric measurements methods. Süleyman Demirel Üniversitesi Sağlık Bilimleri Dergisi. 2015;5(3):94-97. https://izlik.org/JA42UR82DY
Chicago
Akın, Mehmet, Mücella Tezcan, and Zehra İleri. 2015. “Comparison of Conventional and Digital Cepholometric Measurements Methods”. Süleyman Demirel Üniversitesi Sağlık Bilimleri Dergisi 5 (3): 94-97. https://izlik.org/JA42UR82DY.
EndNote
Akın M, Tezcan M, İleri Z (January 1, 2015) Comparison of conventional and digital cepholometric measurements methods. Süleyman Demirel Üniversitesi Sağlık Bilimleri Dergisi 5 3 94–97.
IEEE
[1]M. Akın, M. Tezcan, and Z. İleri, “Comparison of conventional and digital cepholometric measurements methods”, Süleyman Demirel Üniversitesi Sağlık Bilimleri Dergisi, vol. 5, no. 3, pp. 94–97, Jan. 2015, [Online]. Available: https://izlik.org/JA42UR82DY
ISNAD
Akın, Mehmet - Tezcan, Mücella - İleri, Zehra. “Comparison of Conventional and Digital Cepholometric Measurements Methods”. Süleyman Demirel Üniversitesi Sağlık Bilimleri Dergisi 5/3 (January 1, 2015): 94-97. https://izlik.org/JA42UR82DY.
JAMA
1.Akın M, Tezcan M, İleri Z. Comparison of conventional and digital cepholometric measurements methods. Süleyman Demirel Üniversitesi Sağlık Bilimleri Dergisi. 2015;5:94–97.
MLA
Akın, Mehmet, et al. “Comparison of Conventional and Digital Cepholometric Measurements Methods”. Süleyman Demirel Üniversitesi Sağlık Bilimleri Dergisi, vol. 5, no. 3, Jan. 2015, pp. 94-97, https://izlik.org/JA42UR82DY.
Vancouver
1.Mehmet Akın, Mücella Tezcan, Zehra İleri. Comparison of conventional and digital cepholometric measurements methods. Süleyman Demirel Üniversitesi Sağlık Bilimleri Dergisi [Internet]. 2015 Jan. 1;5(3):94-7. Available from: https://izlik.org/JA42UR82DY