Research Article

EVALUATION OF THE DEPENDENCY OF THE COMPRESSIVE STRENGTH OF CONCRETE ON THE CORE DRILLING DIRECTION THROUGH ANOVA TEST

Volume: 38 Number: 4 October 5, 2021
  • Şakir Erdoğdu
  • Safa Nayır
  • Ufuk Kandıl
  • Şirin Kurbetcı Kurbetcı
  • Memduh Nas
EN

EVALUATION OF THE DEPENDENCY OF THE COMPRESSIVE STRENGTH OF CONCRETE ON THE CORE DRILLING DIRECTION THROUGH ANOVA TEST

Abstract

Determination of the compressive strength of concrete in existing reinforced concrete structures is important, particularly in some cases. Destructive and non-destructive test methods are used to determine the compressive strength in such structures. Amongst these, coring is the most widely used method as a destructive method in determining the compressive strength in existing reinforced concrete structures. However, even though numerous studies have been carried out on the variation of the determined compressive strength depending on the coring direction, the discussions continue. In this study, concrete blocks containing fly ash (FA) and silica fume (SF) and aggregates of different maximum sizes were produced. In the mixtures, cement was replaced by fly ash at ratios of 20%, 40%, and 60% and silica fume at ratios of 5%, 10%, and 15%, respectively. Two aggregates with the maximum aggregate sizes of 16 mm and 31.5 mm were used in the production of the concrete blocks. The concrete blocks were kept in a laboratory by covering them with burlaps moistened intermittently for 28 days and then cores of 10 cm diameter were taken and cut to have 20 cm height then capped and tested to determine compressive strength. Core drilling was carried out parallel and perpendicular to the casting direction and then the compressive strengths were determined. Cubes of 15 cm were also prepared and tested to determine the compressive strength level of concrete and to make comparisons accordingly. The compressive strength of mineral-added core samples taken parallel to the casting direction is higher than those of taken perpendicular to the casting direction, in all mixtures. The ANOVA test applied on the results obtained, it was found that the maximum aggregate size (Dmax) and the core drilling direction with respect to casting direction is statistically significant in terms of the compressive strength of concrete produced using fly ash and silica fume at certain substitution ratios.

Keywords

References

  1. [1] Shaikh FUA., Taweel M., (2015) Compressive strength and failure behaviour of fibre reinforced concrete at elevated temperatures. Advance in Concrete Construction 3 (4), 283- 293. doi.org/10.12989/acc.2015.3.4.283.
  2. [2] Allahverdi A., Mahinroosta M., Pilehvar S., (2017) A temperature–age model for prediction of compressive strength of chemically activated high phosphorus slag content cement. International Journal of Civil Engineering 15, 839-847. doi.org/10. 1007/s40999-017-0196-5.
  3. [3] ASTM C42-90, (1992) Standard test method for obtaining and testing drilled cores and sawed beams of concretes. ASTM International, West Conshohocken, PA, USA.
  4. [4] Sullivan PJE., (1991) Testing and evaluation of concrete strength in structures. ACI Materials Journal 88 (5), 530-535.
  5. [5] Price WF., Hynes FP., (1996) In-situ strength testing of high strength concrete. Magazine of Concrete Research,48 (176),189-197. doi.org/10.1680/macr.1996.48.176.189.
  6. [6] Kot P., Shaw A., Riley M., Ali AS., Cotgrave A., (2017) The feasibility of using electromagnetic waves in determining membrane failure through concrete. International Journal of Civil Engineering 15, 355-362. doi.org/10. 1007/s40999-016-0074-6.
  7. [7] Meininger RC., Wagner FT., Hall KW., (1977) Concrete core strength-The effect of length to diameter ratio. Journal of Testing and Evaluation 5 (3), 147-153. doi.org/10.1520/JTE11631J.
  8. [8] Bartlett FM., MacGregor JG., (1994) Cores from high-performance concrete beams. ACI Materials Journal 91, 567-576.

Details

Primary Language

English

Subjects

-

Journal Section

Research Article

Authors

Şakir Erdoğdu This is me
0000-0002-3440-7189
Türkiye

Şirin Kurbetcı Kurbetcı This is me
0000-0002-2000-571X
Palestine

Publication Date

October 5, 2021

Submission Date

May 25, 2020

Acceptance Date

October 22, 2020

Published in Issue

Year 2020 Volume: 38 Number: 4

APA
Erdoğdu, Ş., Nayır, S., Kandıl, U., Kurbetcı, Ş. K., & Nas, M. (2021). EVALUATION OF THE DEPENDENCY OF THE COMPRESSIVE STRENGTH OF CONCRETE ON THE CORE DRILLING DIRECTION THROUGH ANOVA TEST. Sigma Journal of Engineering and Natural Sciences, 38(4), 1879-1895. https://izlik.org/JA25BJ97ZZ
AMA
1.Erdoğdu Ş, Nayır S, Kandıl U, Kurbetcı ŞK, Nas M. EVALUATION OF THE DEPENDENCY OF THE COMPRESSIVE STRENGTH OF CONCRETE ON THE CORE DRILLING DIRECTION THROUGH ANOVA TEST. SIGMA. 2021;38(4):1879-1895. https://izlik.org/JA25BJ97ZZ
Chicago
Erdoğdu, Şakir, Safa Nayır, Ufuk Kandıl, Şirin Kurbetcı Kurbetcı, and Memduh Nas. 2021. “EVALUATION OF THE DEPENDENCY OF THE COMPRESSIVE STRENGTH OF CONCRETE ON THE CORE DRILLING DIRECTION THROUGH ANOVA TEST”. Sigma Journal of Engineering and Natural Sciences 38 (4): 1879-95. https://izlik.org/JA25BJ97ZZ.
EndNote
Erdoğdu Ş, Nayır S, Kandıl U, Kurbetcı ŞK, Nas M (October 1, 2021) EVALUATION OF THE DEPENDENCY OF THE COMPRESSIVE STRENGTH OF CONCRETE ON THE CORE DRILLING DIRECTION THROUGH ANOVA TEST. Sigma Journal of Engineering and Natural Sciences 38 4 1879–1895.
IEEE
[1]Ş. Erdoğdu, S. Nayır, U. Kandıl, Ş. K. Kurbetcı, and M. Nas, “EVALUATION OF THE DEPENDENCY OF THE COMPRESSIVE STRENGTH OF CONCRETE ON THE CORE DRILLING DIRECTION THROUGH ANOVA TEST”, SIGMA, vol. 38, no. 4, pp. 1879–1895, Oct. 2021, [Online]. Available: https://izlik.org/JA25BJ97ZZ
ISNAD
Erdoğdu, Şakir - Nayır, Safa - Kandıl, Ufuk - Kurbetcı, Şirin Kurbetcı - Nas, Memduh. “EVALUATION OF THE DEPENDENCY OF THE COMPRESSIVE STRENGTH OF CONCRETE ON THE CORE DRILLING DIRECTION THROUGH ANOVA TEST”. Sigma Journal of Engineering and Natural Sciences 38/4 (October 1, 2021): 1879-1895. https://izlik.org/JA25BJ97ZZ.
JAMA
1.Erdoğdu Ş, Nayır S, Kandıl U, Kurbetcı ŞK, Nas M. EVALUATION OF THE DEPENDENCY OF THE COMPRESSIVE STRENGTH OF CONCRETE ON THE CORE DRILLING DIRECTION THROUGH ANOVA TEST. SIGMA. 2021;38:1879–1895.
MLA
Erdoğdu, Şakir, et al. “EVALUATION OF THE DEPENDENCY OF THE COMPRESSIVE STRENGTH OF CONCRETE ON THE CORE DRILLING DIRECTION THROUGH ANOVA TEST”. Sigma Journal of Engineering and Natural Sciences, vol. 38, no. 4, Oct. 2021, pp. 1879-95, https://izlik.org/JA25BJ97ZZ.
Vancouver
1.Şakir Erdoğdu, Safa Nayır, Ufuk Kandıl, Şirin Kurbetcı Kurbetcı, Memduh Nas. EVALUATION OF THE DEPENDENCY OF THE COMPRESSIVE STRENGTH OF CONCRETE ON THE CORE DRILLING DIRECTION THROUGH ANOVA TEST. SIGMA [Internet]. 2021 Oct. 1;38(4):1879-95. Available from: https://izlik.org/JA25BJ97ZZ