Abstract

Titanium alloys, especially Ti6Al4V, are widely used in in-body implants due to their superior mechanical properties, corrosion resistance and biocompatibility. However, due to their higher modulus of elasticity than bone, they do not bond well with the bone structure, leading to loosening. In addition, they contain the elements Al and V, both of which are dangerous when released into the body. Therefore, these alloys are subjected to a number of surface treatments to improve their surface properties. In this study, Ti6Al4V alloys were produced by selective laser melting in dimensions of 10x10x2 mm3 and then surface treated. The alloy surfaces were first anodized and then coated with 45S5 bioglass powder. After all surface processes, structural analyzes were performed and the effectiveness of the coating was examined. The untreated and coated samples were subjected to corrosion tests by cyclic polarization method and their corrosion behaviors were investigated.

Keywords

References

  1. Molina J, Valero-Gómez A, Belda, J, Bosch F, Bernabé-Quispe P, Tormo-Mas MA. Long-term antibacterial Ag+-release biomaterials based on anodized Ti6Al4V and silver nanoparticles. Colloids and Surfaces A: Physicochemical and Engineering Aspects. 2023; 676(B): 1-15.
  2. Atik, B., Bozkurt, Y. B., Kavasoğlu, Y. S., Kovacı, H., & Çelik, A. (2024). Pitting corrosion performance of plasma oxidized Cp-Ti and effects of fabrication methods. Surface and Coatings Technology, 130384.
  3. Zhang LC, Chen, LY. A review on biomedical titanium alloys: recent progress and prospect. Adv. Eng. Mater. 2019; 21: 1801215.
  4. Magesh S, Vasanth G, Revathi A, Geeth M. Use of nanostructured materials in implants, in: R. Narayan (Ed.). Nanobiomaterials, Nanostructured Materials for Biomedical Applications, Woodhead Publishing. 2018; 481-501.
  5. Leban MB, Kosec T, Finšgar M. Corrosion characterization and ion release in SLM-manufactured and wrought Ti6Al4V alloy in an oral environment. Corrosion Science. 2022; 209: 1-15.
  6. Mei S, Wang H, Wang W, Tong L, Pan H, Ruan C, Ma Q, Liu M, Yang H, Zhang L, Cheng Y, Zhang Y, Zhao L, Chu PK. Antibacterial effects and biocompatibility of titanium surfaces with graded silver incorporation in titania nanotubes. Biomaterials. 2014; 35: 4255-4265.
  7. He W, Yin X, Xie L, Liu Z, Li J, Zou S, Chen J. Enhancing osseointegration of titanium implants through large-grit sandblasting combined with micro-arc oxidation surface modification. J. Mater. Sci: Mater. Med. 2019; 30: 73.
  8. Herrero-Climent M, Lázaro P, Vicente Rios J, Lluch S, Marqués M, Guillem-Martí J, Gil FJ. Influence of acid-etching after grit-blasted on osseointegration of titanium dental implants: in vitro and in vivo studies. J. Mater. Sci.: Mater. Med. 2013; 24: 2047-2055.

Details

Primary Language

English

Subjects

Biomaterials in Biomedical Engineering, Biomechanical Engineering

Journal Section

Research Article

Publication Date

October 1, 2024

Submission Date

January 25, 2024

Acceptance Date

April 24, 2024

Published in Issue

Year 2024 Number: 1

APA
Tüzemen, Ş. M., Bozkurt, Y. B., Atik, B., Uzun, Y., & Çelik, A. (2024). Investigation of the Effect of Bioactive Glass Coating on the Corrosion Behavior of Pre-treated Ti6Al4V Alloy. Türk Doğa Ve Fen Dergisi, 1, 87-91. https://doi.org/10.46810/tdfd.1425792
AMA
1.Tüzemen ŞM, Bozkurt YB, Atik B, Uzun Y, Çelik A. Investigation of the Effect of Bioactive Glass Coating on the Corrosion Behavior of Pre-treated Ti6Al4V Alloy. TJNS. 2024;(1):87-91. doi:10.46810/tdfd.1425792
Chicago
Tüzemen, Şükran Merve, Yusuf Burak Bozkurt, Burak Atik, Yakup Uzun, and Ayhan Çelik. 2024. “Investigation of the Effect of Bioactive Glass Coating on the Corrosion Behavior of Pre-Treated Ti6Al4V Alloy”. Türk Doğa Ve Fen Dergisi, no. 1: 87-91. https://doi.org/10.46810/tdfd.1425792.
EndNote
Tüzemen ŞM, Bozkurt YB, Atik B, Uzun Y, Çelik A (October 1, 2024) Investigation of the Effect of Bioactive Glass Coating on the Corrosion Behavior of Pre-treated Ti6Al4V Alloy. Türk Doğa ve Fen Dergisi 1 87–91.
IEEE
[1]Ş. M. Tüzemen, Y. B. Bozkurt, B. Atik, Y. Uzun, and A. Çelik, “Investigation of the Effect of Bioactive Glass Coating on the Corrosion Behavior of Pre-treated Ti6Al4V Alloy”, TJNS, no. 1, pp. 87–91, Oct. 2024, doi: 10.46810/tdfd.1425792.
ISNAD
Tüzemen, Şükran Merve - Bozkurt, Yusuf Burak - Atik, Burak - Uzun, Yakup - Çelik, Ayhan. “Investigation of the Effect of Bioactive Glass Coating on the Corrosion Behavior of Pre-Treated Ti6Al4V Alloy”. Türk Doğa ve Fen Dergisi. 1 (October 1, 2024): 87-91. https://doi.org/10.46810/tdfd.1425792.
JAMA
1.Tüzemen ŞM, Bozkurt YB, Atik B, Uzun Y, Çelik A. Investigation of the Effect of Bioactive Glass Coating on the Corrosion Behavior of Pre-treated Ti6Al4V Alloy. TJNS. 2024;:87–91.
MLA
Tüzemen, Şükran Merve, et al. “Investigation of the Effect of Bioactive Glass Coating on the Corrosion Behavior of Pre-Treated Ti6Al4V Alloy”. Türk Doğa Ve Fen Dergisi, no. 1, Oct. 2024, pp. 87-91, doi:10.46810/tdfd.1425792.
Vancouver
1.Şükran Merve Tüzemen, Yusuf Burak Bozkurt, Burak Atik, Yakup Uzun, Ayhan Çelik. Investigation of the Effect of Bioactive Glass Coating on the Corrosion Behavior of Pre-treated Ti6Al4V Alloy. TJNS. 2024 Oct. 1;(1):87-91. doi:10.46810/tdfd.1425792

This work is licensed under the Creative Commons Attribution-Non-Commercial-Non-Derivable 4.0 International License.