Research Article

Investigation of FRP Strengthening Design Rules for Insufficient RC Columns

Volume: 21 Number: 105 October 1, 2010
  • Okan Özcan
  • Barış Binici
  • Güney Özcebe
EN TR

Investigation of FRP Strengthening Design Rules for Insufficient RC Columns

Abstract

Increasing the deformation capacities of code-incompliant RC columns by wrapping their potential plastic hinge regions with fiber-reinforced polymer (FRP) has become a rather popular strengthening technique in recent years. FRP design guidelines are included in the 7th chapter of the Turkish Earthquake Code (TEC-07) that became effective in 2007. This study intends to scrutinize the design approach of TEC-07 in light of the test results of 10 columns tested under axial load and cyclic displacement excursions at METU and the test results of 18 columns gathered from literature. After careful investigations, it was clearly seen that in TEC-07, the FRP wrapped column performance limits were over conservative and led to uneconomical designs. Two different design methods were developed. The first one is compatible with the current code procedure and the other is based on interstory drifts in order to obtain simpler and more economical FRP design in addition to its accuracy. 

Keywords

Details

Primary Language

English

Subjects

Engineering

Journal Section

Research Article

Authors

Okan Özcan This is me

Barış Binici This is me

Güney Özcebe This is me

Publication Date

October 1, 2010

Submission Date

June 18, 2015

Acceptance Date

-

Published in Issue

Year 2010 Volume: 21 Number: 105

APA
Özcan, O., Binici, B., & Özcebe, G. (2010). Investigation of FRP Strengthening Design Rules for Insufficient RC Columns. Teknik Dergi, 21(105), 1425-1444. https://izlik.org/JA95MB77EZ
AMA
1.Özcan O, Binici B, Özcebe G. Investigation of FRP Strengthening Design Rules for Insufficient RC Columns. Teknik Dergi. 2010;21(105):1425-1444. https://izlik.org/JA95MB77EZ
Chicago
Özcan, Okan, Barış Binici, and Güney Özcebe. 2010. “Investigation of FRP Strengthening Design Rules for Insufficient RC Columns”. Teknik Dergi 21 (105): 1425-44. https://izlik.org/JA95MB77EZ.
EndNote
Özcan O, Binici B, Özcebe G (October 1, 2010) Investigation of FRP Strengthening Design Rules for Insufficient RC Columns. Teknik Dergi 21 105 1425–1444.
IEEE
[1]O. Özcan, B. Binici, and G. Özcebe, “Investigation of FRP Strengthening Design Rules for Insufficient RC Columns”, Teknik Dergi, vol. 21, no. 105, pp. 1425–1444, Oct. 2010, [Online]. Available: https://izlik.org/JA95MB77EZ
ISNAD
Özcan, Okan - Binici, Barış - Özcebe, Güney. “Investigation of FRP Strengthening Design Rules for Insufficient RC Columns”. Teknik Dergi 21/105 (October 1, 2010): 1425-1444. https://izlik.org/JA95MB77EZ.
JAMA
1.Özcan O, Binici B, Özcebe G. Investigation of FRP Strengthening Design Rules for Insufficient RC Columns. Teknik Dergi. 2010;21:1425–1444.
MLA
Özcan, Okan, et al. “Investigation of FRP Strengthening Design Rules for Insufficient RC Columns”. Teknik Dergi, vol. 21, no. 105, Oct. 2010, pp. 1425-44, https://izlik.org/JA95MB77EZ.
Vancouver
1.Okan Özcan, Barış Binici, Güney Özcebe. Investigation of FRP Strengthening Design Rules for Insufficient RC Columns. Teknik Dergi [Internet]. 2010 Oct. 1;21(105):1425-44. Available from: https://izlik.org/JA95MB77EZ