Araştırma Makalesi

Investigation of FRP Strengthening Design Rules for Insufficient RC Columns

Cilt: 21 Sayı: 105 1 Ekim 2010
  • Okan Özcan
  • Barış Binici
  • Güney Özcebe
PDF İndir
EN TR

Investigation of FRP Strengthening Design Rules for Insufficient RC Columns

Öz

Increasing the deformation capacities of code-incompliant RC columns by wrapping their potential plastic hinge regions with fiber-reinforced polymer (FRP) has become a rather popular strengthening technique in recent years. FRP design guidelines are included in the 7th chapter of the Turkish Earthquake Code (TEC-07) that became effective in 2007. This study intends to scrutinize the design approach of TEC-07 in light of the test results of 10 columns tested under axial load and cyclic displacement excursions at METU and the test results of 18 columns gathered from literature. After careful investigations, it was clearly seen that in TEC-07, the FRP wrapped column performance limits were over conservative and led to uneconomical designs. Two different design methods were developed. The first one is compatible with the current code procedure and the other is based on interstory drifts in order to obtain simpler and more economical FRP design in addition to its accuracy. 

Anahtar Kelimeler

Ayrıntılar

Birincil Dil

İngilizce

Konular

Mühendislik

Bölüm

Araştırma Makalesi

Yazarlar

Okan Özcan Bu kişi benim

Barış Binici Bu kişi benim

Güney Özcebe Bu kişi benim

Yayımlanma Tarihi

1 Ekim 2010

Gönderilme Tarihi

18 Haziran 2015

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 2010 Cilt: 21 Sayı: 105

Kaynak Göster

APA
Özcan, O., Binici, B., & Özcebe, G. (2010). Investigation of FRP Strengthening Design Rules for Insufficient RC Columns. Teknik Dergi, 21(105), 1425-1444. https://izlik.org/JA95MB77EZ
AMA
1.Özcan O, Binici B, Özcebe G. Investigation of FRP Strengthening Design Rules for Insufficient RC Columns. Teknik Dergi. 2010;21(105):1425-1444. https://izlik.org/JA95MB77EZ
Chicago
Özcan, Okan, Barış Binici, ve Güney Özcebe. 2010. “Investigation of FRP Strengthening Design Rules for Insufficient RC Columns”. Teknik Dergi 21 (105): 1425-44. https://izlik.org/JA95MB77EZ.
EndNote
Özcan O, Binici B, Özcebe G (01 Ekim 2010) Investigation of FRP Strengthening Design Rules for Insufficient RC Columns. Teknik Dergi 21 105 1425–1444.
IEEE
[1]O. Özcan, B. Binici, ve G. Özcebe, “Investigation of FRP Strengthening Design Rules for Insufficient RC Columns”, Teknik Dergi, c. 21, sy 105, ss. 1425–1444, Eki. 2010, [çevrimiçi]. Erişim adresi: https://izlik.org/JA95MB77EZ
ISNAD
Özcan, Okan - Binici, Barış - Özcebe, Güney. “Investigation of FRP Strengthening Design Rules for Insufficient RC Columns”. Teknik Dergi 21/105 (01 Ekim 2010): 1425-1444. https://izlik.org/JA95MB77EZ.
JAMA
1.Özcan O, Binici B, Özcebe G. Investigation of FRP Strengthening Design Rules for Insufficient RC Columns. Teknik Dergi. 2010;21:1425–1444.
MLA
Özcan, Okan, vd. “Investigation of FRP Strengthening Design Rules for Insufficient RC Columns”. Teknik Dergi, c. 21, sy 105, Ekim 2010, ss. 1425-44, https://izlik.org/JA95MB77EZ.
Vancouver
1.Okan Özcan, Barış Binici, Güney Özcebe. Investigation of FRP Strengthening Design Rules for Insufficient RC Columns. Teknik Dergi [Internet]. 01 Ekim 2010;21(105):1425-44. Erişim adresi: https://izlik.org/JA95MB77EZ